Tear the tab off the tube of silicon dielectric compound that came with the sensor.

Squeeze about half of the compound on the connector at the base of the sensor.

Insert the cable connector into the sensor connector. Be aware it’s a keyed connector.

Twist the cable connector clockwise until you hear it click into place.

Run the cable through the pole. Leave a small amount of slack at the top; this reduc-

es strain, allows you to create a drip loop as shown above, and gives you something 

to work with should you need to move the sensor’s spot on the pole in the future.

If you’re using a junction box, terminate the cable in it, then run a homerun cable from there to the cabi-

net. If you’re not using a junction box, run the sensor cable to the cabinet. In either case, do not strip the 

insulation on the conductors when terminating the cable.

Place the Click 65x on a shelf or mount it to the side of the cabinet, and connect the sensor cable(s) to the terminal block plug(s).

Make sure each switch by the sensor port is turned on and the LED is illuminated. 

If your cabinet is SDLC compatible, connect a cable from the SDLC bus on the Click 65x to the controller. If your cabinet isn’t SDLC 

compatible, you can connect from the sensor port RJ-11 jacks to contact closure cards and communicate with the controller that way.

7

  Configure the Click 65x

8

  Check sensor operation in the SmartSensor Manager Matrix software

5

  Attach the cable

6

  Install cabinet equipment

The Click 65x is designed to be communicated with over Ethernet. Before you can connect it to your network, you need to set the static 

IP address, subnet mask and default gateway (these numbers should be determined by your IT personnel).

Use the arrow keys and screen on the faceplate to navigate the OLED menu. 

On the main screen, navigate down to Network Setup and press the 

Accept

 

(green check mark) button to open the networking screen (shown at right).

Set your desired IP address by following these steps: use the left and right 

arrow keys to highlight a number, then use the up and down arrow keys to 

change that number. Then move to the next number. Repeat until all the 

numbers are changed.

Press the right key one last time to navigate down to the subnet mask line.

Repeat steps 2 and 3 for the subnet mask and default gateway.

When you’re done with all three, push the check mark button to confirm your changes.

After you’re done, connect an Ethernet cable to the RJ-45 jack on the faceplate of the device to connect your Click 65x to your network.

Click 

Communication

 on the main screen and then click the cloud icon at the top of the screen.

Under 

Network Address

, enter the IP address and port number of the Click 65x.

Click 

Search

. The first time you connect, use a 

Full 

search, which will find all the Matrix sensors 

on the selected RS-485 control bus. A 

Quick

 search can be used for any subsequent connections.

Once the list of sensors appears, click on the sensor you would like to configure; click 

Connect

.

On the main menu, click 

Sensor Setup

. The screen that opens shows vehicle detections as moving 

blue dots, called trackers. If the trackers match traffic on the road, the sensor is working properly. 

Note. 

For configuration instructions, see the 

SmartSensor Matrix User Guide

.