Terminate the SmartSensor 6-conductor cable
9
Complete wiring
To land the 6-conductor cable into the terminal block section:
1
After routing your SmartSensor 6-conductor cable into the cabinet, strip
back the cable jacket and shielding on the service end of the cable.
2
Open the insulation displacement connectors on the plug by inserting a
small screwdriver into each square slot and rocking it back.
3
Insert the wire leads into the bottom side of the plug-in terminal accord-
ing to the colors of the wires and the labels on the plug. Make sure the
wires are completely inserted in the terminal.
4
Close the insulation displacement connector by reinserting the screwdriver into the square slot and
rocking it forward. The plug-in terminals will automatically complete the electrical connection. There is
no need to manually strip the insulation on the end of each wire.
5
If you removed the plug to wire it, insert it back into the terminal block section.
The Click 222 has three RJ-11 jacks on the faceplate:
˽
RS-485 A (yellow) –
Connects the data bus from sensor 1 to the rack cards.
˽
RS-485 B (orange) – Connects the data bus from sensor 2 to the rack cards.
˽
RS-485 Bridge (blue) –
Connects the configuration buses from sensors 1 and 2 to the
control bridge, to the detector rack cards, and to the T-bus. This jack combines the
input from ports C and D.
To connect and autobaud to the detector rack cards:
1
Connect from the Click 222 RS-485 A port to a bus 1 port on the appropriate rack
card. Connect from the Click 222 RS-485 B port to a bus 1 port on another rack card.
2
If you are using Click 112 cards, use a patch cord to share bus 1 between cards dedicated to the
same sensor. If you have more than two sensors in your system, repeat steps 1–3 to connect
bus 1 for all remaining rack cards.
3
Connect from a Click 222 bridge port to bus 2 of the rack cards.
4
Daisy-chain between the bus 2 ports of all of the rack cards for device configuration.
5
The Click 112/114 should begin to receive data from the sensor.
4
Turn on AC mains power.
5
Press the circuit breaker switch on the left side of the top DIN rail to switch power to the backplate.
6
Verify power is regulated by verifying that the DC OK LEDs are illuminated on the Click 201/202/204.