5

  Install Click Supervisor

Click Supervisor will be used to configure the Click 400. To install it:

Download the setup file from www.wavetronix.com (under 

Support

).

Double-click on the file to run the setup wizard. Follow the steps to install.

6

  Make a connection

Make sure there is a connection between the Click 400 and the computer that 

Click Supervisor is on. This can be through the DB-9 connector on the module 

or through another device also on the T-bus; for example, the Click 421 can 

communicate with the computer through Bluetooth®.

Run Click Supervisor and select 

Communication

. The Click 400 can only be 

configured using serial communication.

Click 

Settings

 to make any necessary changes to the settings, such as the port or 

the baud rate. Click 

OK

 to return to the Communication screen, then click 

Con-

nect

. Keep the Click ID set to 0.

In the next screen, Click Supervisor will display all the devices it discovers. 

When the Click 400 appears, select it and click 

Select

. Click Supervisor will connect to the device.

7

  Select a driver

Select 

Setup Click

 on the main screen.

Select the appropriate driver for your application:

 

˽

Client –

 If you connect multiple clients to a 

single server

 

˽

Server –

 If you connect a single radio to an-

other single radio

 

˽

SmartSensor Client –

 If you connect a wireless 

sensor station to a wireless base station

 

˽

SmartSensor Server –

 If you connect a wireless 

base station to a wireless sensor station

 

˽

Expert –

 Use only when instructed to by Wa-

vetronix Technical Services

Click 

OK

.

Once that driver has loaded, you can use it to change functional and informational settings.

8

  Configure the module

Change any necessary settings in the Setup tab (RF channel may be the only one that needs changing).

 

˽

Description/Location –

 For informational/identification purposes only.

 

˽

Device ID –

 Changes the ID number associated with the device. By default this is 

the last five digits of the serial number.

 

˽

RF Channel –

 The frequency channel of the device. If you perform a link test, each 

client and server must be on the same channel.

 

˽

Tx Power –

 Lets you modify the transmit power level.

 

˽

Baud Rate –

 If connecting to a sensor, this must match the sensor’s baud rate.