background image

www.wavetronix.com  

801.734.7200

Click 330 Ethernet Switch

QUICK START GUIDE

1

  Mount the device

The Click 330 mounts on a DIN rail. To mount, simply hook 

the lip over the lower edge of the DIN rail, and use a rocking 

motion to snap the module into place.

Note.

 

Do not mount over the T-bus.

Unlike many other Click devices, the Click 330 does not mount over the T-bus, mean-

ing that power and communications will have to be wired in into the device’s six screw 

terminals. The first four screw terminals, marked US1, GND, US2 and GND, are for wiring 

power. (The other two, which are labeled R1 and R2, are for security and functionality 

alarm purposes.)

Attach the device to a location on the DIN rail that is not over a T-bus.

Attach a wire for +DC (red is standard) to the screw terminal marked US1.

Attach a wire for -DC (black is standard) to the first screw terminal marked GND.

Attach the other ends of these two wires to a DC power source.

Note. 

US2 and the second GND are for wiring in a redundant power supply, if you’d like 

to use one.

The device has a grounding foot, so as long as the DIN rail is 

properly grounded, the device will be grounded as well.

However, for additional protection, the switch can be grounded 

via an eyelet ring on the top of the device.

3

  Ground the device

2

  Wire power

The Click 330 is used for quick and cost-effective Ethernet network expansion at the field level. The RJ-45 ports offer au-

to-crossing and auto-negotiation functionality. For more information about this product, visit wavetronix.com. 

4

  Wire communication

Attach Ethernet cables to the RJ-45 jacks on the Click 330.