  Configuration option 3: Click Supervisor

Install Click Supervisor

Click Supervisor is the third available way to configure the Click 112/114. To 

install it:

Download the setup file from www.wavetronix.com (under 

Support

).

Double-click on the file to run the setup wizard. Follow the steps to install.

Make a connection

Make sure there is a connection between the Click 112/114 and the com-

puter that Click Supervisor is on. To do this, there should be a jumper cable 

connected from the bus 2 port to a Click device with an RJ-11 jack on the 

T-bus, such as a Click 222.

Run Click Supervisor and select 

Communication

. This screen lets you pick the type of connection you 

want to make, serial or IP. The Click 112/114 will likely be configured using serial communication.

Click 

Settings

 to make any necessary changes to the settings, such as the port or the baud rate. Click 

OK

 to return to the Communication screen, then click 

Connect

. Keep the Click ID set to 0.

In the next screen, Click Supervisor will display all the devices it discovers. When the desired Click 

112/114 appears, select it and click 

Select

. Click Supervisor will connect to the device.

Select a driver

Select 

Setup Click

 on the main screen. In the next 

screen, select the 

Expert

 driver and click 

OK

.

Configure the module

The 

System > General

 tab has text parameters that 

cannot be changed anywhere else. The most important 

of these include:

 

˽

Description/Location –

 For informational/iden-

tification purposes only. These settings do not 

affect the operation of the device.

 

˽

Device ID –

 Changes the ID number associated with the device. By default this is the last five digits of the 

serial number. The 

System > Settings

 tab lets you set certain parameters that can also be changed using the 

front panel menu and the DIP switches.

 

˽

Baud Rate for Bus 1/2 –

 Changes the baud rates of buses 1 and 2.

 

˽

Input Mapping –

 Lets you map two or four of the input data channels coming from the sensor to the 

output channels on the device. The outputs are assigned sequentially, so if you select 13–14, then input 

13 will be mapped to channel 1, and 14 to channel 2.

Note. 

If any of the DIP switches are turned on, that parameter will be in Hardware mode and Click Supervi-

sor will only be able to display, not change, that setting.