Follow the steps below to wire 

the contact closure outputs to 

a controller, data logger or BIU 

(bus interface unit): 

Wire the screw terminals 

on the top of the device 

labeled 1–8. These termi-

nals represent the primary 

outputs with primary one (P1) representing the lane closest to the sensor. For dual-loop emulation, the contact closure 

outputs must be wired with the primary always leading the secondary.

Wire the bottom screw terminals also labeled 1–8. These terminals represent the secondary outputs, with secondary one 

(S1) representing the lane closest to the sensor.

Wire one of the remaining GND screw terminals to a logic ground. One GND terminal must be connected for the primary 

and secondary outputs to function.

4

  Wire contact closure outputs

Primary Detector

Secondary Detector

Traffic Direction

Selection

Operating mode

Presence –

 Outputs contact closures for single-loop or dual-loop emulation. Dual-loop emulation will signal 

the radar’s speed and duration measurements; single-loop emulation will signal the radar’s duration (no 

speed information).

Pulse – 

Outputs contact closures for single-loop or dual-loop emulation. Dual-loop emulation will signal 

the radar’s speed measurement using the time elapsed between the onset of the primary and secondary 

outputs (no duration measurement); single-loop emulation will signal that the radar detected a vehicle (no 

duration or speed information).

Actuation –

 Outputs contact closures for single-loop emulation. This is the only mode used by SmartSensor 

Advance.

One-Loop Speed –

 Outputs contact closures for single-loop emulation. The duration is based upon the 

speed of the detected vehicle.

Autobaud –

 Hold the push-button until the green LED flashes. While autobauding, the green and yellow 

LEDs will flash intermittently, as well as the 16 digital output LEDs. If the autobauding is unsuccessful, the 

LEDs will remain in that state indefinitely. If it’s successful, the yellow LED will flash, then the device will 

return to its normal state and default to the Presence mode. 