ANT-20/ANT-20E
Broadband Analyzer/Generator
Application Guide
A-17
Channel Status
The “Channel Status” field indicates the circuit status of the test channels:
Signaling events
This display field indicates the progress of the signaling. The signaling events are shown
consecutively in separate lines, each with date and time information. Each time there is a
change in the status of the channel circuit, this is indicated in the display field. A channel can
assume any of the following states:
If the “Detailed” check box is marked, additional information will be shown for each change of
status.
Display
The “Display” field allows you to select the signaling information to be displayed in the right-
hand display field and to control the display itself. The following check boxes and action buttons
are provided:
Red
“disconnected”
Circuit disconnected.
Yellow
“connecting”
Circuit in process of connecting.
Green
“connected”
Circuit connected (switched).
disconnected
Circuit disconnected
connecting
Circuit in process of connecting
connected
Circuit connected (switched)
for “disconnected”: Indication of reason for disconnection
for “connecting”:
Address of called instrument and traffic contract
parameters (for called instrument only)
for “connected”:
VPI/VCI values for the switched test channel and the
call set up time (for calling instrument only)
Detailed
Check box for selecting the degree of detail in the displayed
information:
“Detailed” off:
Display of circuit status only (e.g. connected)
“Detailed” on:
Display of additional information. If the “Log QoS Parameters” is
selected, the measured QoS parameters will also be displayed
All channels
Check box for displaying all channels
A, B, ...
Check box for displaying a specific test channel
Page:
Display of the displayed page number and the total number of pages
<
Action button for paging backwards
>
Action button for paging forwards
Содержание ANT-20
Страница 8: ...Broadband Analyzer Generator ANT 20 ANT 20E vi Notes ...
Страница 64: ...Broadband Analyzer Generator ANT 20 ANT 20E O 46 Operation Notes ...
Страница 110: ...Broadband Analyzer Generator ANT 20 ANT 20E TB 16 Technical Background Notes ...
Страница 126: ...Broadband Analyzer Generator ANT 20 ANT 20E iv Notes ...