ANT-20/ANT-20E
Broadband Analyzer/Generator
Specifications “ATM Layer”
S-3
1.5
Functions for ATM Layer Quality of Service Measurements
1.5.1
General
1.5.2
Error Insertion (Anomalies)
The following anomalies can be inserted selectively into each of the 4 test channels. All
anomalies are inserted as a single event.
1.5.3
Alarm Generation
The following defects can be generated selectively on each of the 4 test channels. All defects
are generated as “on/off” functions.
1.5.4
Test Cell Format
Test cell format conforms with ITU-T recommendation O.191, issue of 9th January 1997.
Number of test channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Source models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . “Constant Bit Rate”,
“On-Off”
Traffic Shaper
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .“Single Leaky Bucket”,
“Dual Leaky Bucket”
Maximum total bandwidth of all test channel . . . . . . . . . . . . . . . . . . . . . . . . . . . 366792 cells/s
2
1 Can be disabled
2 In practice, the upper limit is given by the physical mapping
Uncorrectable header error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HUNC
Correctable header error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HCOR
Cell loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cell Loss
Cell error. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cell Error
Cell misinsertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cell Misins.
Severely errored cell block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SECB
F5 layer (VC) Alarm Indication Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VC-AIS
F4 layer (VP) Alarm Indication Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VP-AIS
F5 layer (VC) Remote Defect Indication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VC-RDI
F4 layer (VP) Remote Defect Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VP-RDI
Transmission timestamp resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640 ns
1
1 The lowest value bits of the timestamp are always set to 0
Содержание ANT-20
Страница 8: ...Broadband Analyzer Generator ANT 20 ANT 20E vi Notes ...
Страница 64: ...Broadband Analyzer Generator ANT 20 ANT 20E O 46 Operation Notes ...
Страница 110: ...Broadband Analyzer Generator ANT 20 ANT 20E TB 16 Technical Background Notes ...
Страница 126: ...Broadband Analyzer Generator ANT 20 ANT 20E iv Notes ...