Wavespan Stratum 100 Скачать руководство пользователя страница 1

Stratum 100
Wireless Ethernet Bridge

Installation
and
Maintenance
Guide

Содержание Stratum 100

Страница 1: ...Stratum 100 Wireless Ethernet Bridge Installation and Maintenance Guide...

Страница 2: ...FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may...

Страница 3: ...ible radio frequency exposure outlined in CFR 47 Section 1 1307 b 1 preventing excess exposure to all persons The installed radiating device should be inaccessible to unauthorized personnel The instal...

Страница 4: ...ou must take into account mechanical loading of the rack Heavier equipment should be placed near the bottom of the rack and equipment should not be mounted in such a way as to cause instability Specia...

Страница 5: ...al Connecting a Modem to the AUX Port 6 Step 8 Connecting to a PBX or other T1 device 6 Assembling Tools and Cables Before You Begin 6 For installing the ODUs 6 For the cabling between each IDU and as...

Страница 6: ...ont Panel 29 Connecting to the Stratum 100 29 Using the Console Port 29 Using Telnet and a VT100 Terminal Emulator 31 Using Telnet and a Web Browser 32 Remote Access through the Modem on the AUX Port...

Страница 7: ...iewing Alarms and Events 50 Clearing Old Alarms and Events 51 Understanding the Different Alarm and Event Messages 52 Running Diagnostics 53 Running Diagnostic Tests 53 Checking Software Versions and...

Страница 8: ......

Страница 9: ...and Maintenance Guide About this Manual 1 About this Manual Thank you for purchasing a Wavespan Stratum 100 wireless Ethernet bridge Whom This Manual is Intended For Additional Reading How This Manual...

Страница 10: ......

Страница 11: ...to 5 miles Some Definitions The Stratum 100 consists of two units The Indoor Unit IDU is a rack mounted unit which contains the electronic bridging components The IDU can be located in any convenient...

Страница 12: ...i mode fiber cables Typical system configuration showing the two ODUs mounted on the roofs of two adjacent buildings and the associated IDUs located inside the buildings In topological logical terms t...

Страница 13: ...h survey and chosen locations for the IDUs and ODUs Step 1 Installing and Mounting the ODUs As part of your path survey an appropriate site must be selected for the two ODUs Typically each ODU is atta...

Страница 14: ...face is industry standard DSX 1 Assembling Tools and Cables Before You Begin You will need the following tools before beginning the installation For installing the ODUs socket and or open end wrenches...

Страница 15: ...the edge with the coax connectors vertical polarization The other angle bracket is bolted to the opposite edge Use 5 16 20x1 hex head bolts flat washers and lock nuts at three corners of the ODU as s...

Страница 16: ...building Ground loops can result if two pieces of equipment are grounded to the electrical system ground and if there is a voltage difference between the ground points For electrical protection it is...

Страница 17: ...e from sharp metal edges Secure the cable to prevent abrasion due to movement in the wind Attaching the Cables Be sure that the IDU power switch is OFF before connecting the cables to the ODU Attach t...

Страница 18: ...g List The IDU Kit contains rack mounting brackets and hardware rubber mounting feet for tabletop use only AC line cord RJ 45 console cable straight through CAT 5 cable RJ 45 to DB 9 console adapter a...

Страница 19: ...Stratum 100 Installation and Maintenance Guide Installation 11...

Страница 20: ...E port wiring to standard COM port wiring To perform the initial setup of the Stratum 100 you must connect a PC system running a VT 100 terminal emulator such as the HyperTerminal utility The communic...

Страница 21: ...1 16 01 0 System Administrator DEFAULT Device Name DEFAULT Device Location DEFAULT Link Description DEFAULT Circuit Identifier DEFAULT Alarms Disabled Link Up Down Down Link Setup Passwords Console Po...

Страница 22: ...ecify text strings that identify this IDU ODU combination The Link Description and Circuit Identifier describe the location and circuit of the wireless link Finally use the arrow key to go to the Alar...

Страница 23: ...bled Apply OK Cancel Specify the Transmit PowerLevel by using the space bar to toggle between low and high power Typically low power is used for links spanning less than 800 feet and high power is use...

Страница 24: ...Duplex Half Duplex Interface Type RJ45 TCP IP IP Address 192 168 3 202 IP Subnet Mask 255 255 255 0 Default Gateway 192 168 3 1 Spanning Tree Spanning Tree State Enabled Hello Time 2 Bridge Priority...

Страница 25: ...wed by the single digit power level without a space in between If your link is shorter than 2 miles it is important that you set the transmit power Tx PWR level of both ends as described Excess transm...

Страница 26: ...ad Antenna Aiming Technique to be sure you can see the edges of the peak region 2 Set Azimuth in Center of Peak Signal Using the antenna aiming technique described in Section 13 2 watch the LED to fin...

Страница 27: ...r specified reliability in all weather conditions If the RSSI value is more than 3 dB lower than the Aiming value or the values in the table above one of the following is likely a the link has been se...

Страница 28: ...ance Guide Bringing the Link Up From System Administration use the down arrow to move to the Link Up Down field and then press the space bar to toggle its value to Up Choose Apply to save your change...

Страница 29: ...Stratum 100 Installation and Maintenance Guide Installation 21 If there are Problems...

Страница 30: ...Alarms Events Physical Interface Auto Negotiation Disabled Speed 10 Mb Duplex Half Duplex Interface Type RJ45 TCP IP IP Address 192 168 3 202 IP Subnet Mask 255 255 255 0 Default Gateway 192 168 3 1 S...

Страница 31: ...l T1_Ch1 Test Mark Time 0 Errors 0 Rate 0 Start_BER Stop_BER Reset_Counters Other Tests View Power On Self Test Results Cancel To verify Ethernet connectivity enter the IP address of the remote Stratu...

Страница 32: ...ostic Ended E 1999 03 11 08 20 04 0 System Diagnostic Started E 1999 03 11 08 19 58 0 System Diagnostic Ended E 1999 03 11 08 19 16 0 System Diagnostic Started E 1999 03 11 08 19 13 0 System Diagnosti...

Страница 33: ...increase as data is transmitted across the wireless link To verify that these counts are increasing wait for a few seconds and then press Ctrl U to update the counters Use the down arrow to move to C...

Страница 34: ...do this simply connect a standard RJ45 serial cable to your modem Configuring the Modem Settings for Administrators Dialing In System Admin Modem Config Modem Configuration System Status STBY NOT CONN...

Страница 35: ...Stratum 100 Installation and Maintenance Guide Installation 27 Step 8 Connecting to a PBX...

Страница 36: ......

Страница 37: ...s LAN Tx blinking green Each blink indicates a packet received from the RF link and sent to the Ethernet LAN Rx blinking green Each blink indicates a packet received from the Ethernet Dx on solid gree...

Страница 38: ...ning a VT 100 terminal emulator such as the HyperTerminal utility The communications settings for the console terminal must be 9600 baud 8 bits no parity 1 stop bit no flow control Once the PC is atta...

Страница 39: ...ftware Version 00 01c Copyright c 1996 1998 Access Level Password Entering the Password When it is configured at the factory the Stratum 100 is preset to have the following Access Level superuser Pass...

Страница 40: ...ion and Maintenance Guide Using Telnet and a Web Browser You can also access the Stratum 100 interface using Telnet and a Web browser Simply specify the IP address of the Stratum 100 in the Address fi...

Страница 41: ...cess Level Password Entering the Password When it is configured at the factory the Stratum 100 is preset to have the following Access Level superuser Password wavespan After you enter these two fields...

Страница 42: ...nd it is typically connected to a terminal server or PBX To set the PPP parameters of the AUX port choose System Admin and then select PPP from the System Administration screen PPP Configuration Syste...

Страница 43: ...Access Level Password Entering the Password When it is configured at the factory the Stratum 100 is preset to have the following Access Level superuser Password wavespan After you enter these two fie...

Страница 44: ...ublic Write Community String private Trap Community String snmptrap SNMP Trap Destinations IP Addr Screening 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SNMP Agent...

Страница 45: ...figuration System Status STBY NOT CONNECTED ALARM NEW Alarms Events Dial String 1 AT Dial String 2 AT Init String 1 AT Init String 2 AT Dial Out Time Interval 60 Dial Out Attempts 5 Port Parameters Ba...

Страница 46: ...highlight Read Only fields Editable Fields You may type any alpha or numeric characters in Editable Fields The backspace key can be used in these fields You must press ENTER before going on to regist...

Страница 47: ...11 08 19 58 0 System Diagnostic Ended E 1999 03 11 08 19 16 0 System Diagnostic Started E 1999 03 11 08 19 13 0 System Diagnostic Ended E 1999 03 11 08 18 58 0 System Diagnostic Started E 1999 03 11...

Страница 48: ...s System Status STBY NOT CONNECTED ALARM Alarms Events Local Remote Tx Pkt Count 763 Tx Byte Count 48832 Rx Pkt Count 0 Rx Byte Count 0 Rx Bcast 0 Rx Mcast 0 Rx Corrupt Packets 0 Rx Overruns 0 RF Pkt...

Страница 49: ...el Choosing RF Error Interval will display a screen that shows error intervals Error Intervals System Status STBY NOT CONNECTED ALARM Alarms Events Local Current Interval 04 45 Remote Current Interval...

Страница 50: ...om the Ethernet link and bridged The Tx counter shows the number of packets that were received from the wireless link and transmitted to the Ethernet link Note that Ethernet packets and RF packets are...

Страница 51: ...0 0 0 0 02 45 0 0 0 0 0 03 00 0 0 0 0 0 03 15 0 0 0 0 0 Page Up Page Down Home End Update Cancel Rx Error Intvls Rx Error Intervals System Status STBY NOT CONNECTED ALARM Alarms Events Local Current I...

Страница 52: ...ervals T1 Channel 1 Statistics 1999 03 15 10 43 52 0 Update Clear Cancel T1 Channel 1 intervals T1 Channel 1 Intervals System Status STBY NOT CONNECTED ALARM Alarms Events Local Current Interval 04 45...

Страница 53: ...0 01 45 0 0 0 0 0 0 02 00 0 0 0 0 0 0 02 15 0 0 0 0 0 0 02 30 0 0 0 0 0 0 02 45 0 0 0 0 0 0 03 00 0 0 0 0 0 0 03 15 0 0 0 0 0 0 Page Up Page Down Home End Update Cancel Setting Security Parameters Set...

Страница 54: ...0 Unsuccessful Incoming Call Count 0 Unsuccessful Outgoing Call Count 0 Incoming Connect Time 00 00 00 Outgoing Connect Time 00 00 00 Zero Stats Start Time 1999 03 11 13 35 01 0 Update Cancel Zeroing...

Страница 55: ...Mode ESF Channel 2 Framing Mode ESF Channel 1 Line Coding Format B8ZS Channel 2 Line Coding Format B8ZS Apply OK Cancel Adjusting the PPP Parameters for Directly Connected Devices on the AUX Port Sys...

Страница 56: ...Installation and Maintenance Guide System Admin Console Port Console Port Configuration System Status STBY NOT CONNECTED ALARM Alarms Events Port Parameters Baud Rate 9600 Stop Bits 1 Parity None Hand...

Страница 57: ...t problems with the Stratum 100 do the following steps to isolate the location of the problem 1 Check the LEDs on both IDU units 2 Check the current alarms and events for both IDU units 3 Look at the...

Страница 58: ...n Each blink indicates a packet received from the RF link and sent to the Ethernet off No data is being transmitted to the Ethernet LAN Rx blinking green Each blink indicates a packet received from th...

Страница 59: ...1999 03 11 08 18 58 0 System Diagnostic Started E 1999 03 11 08 18 51 0 System Diagnostic Ended E 1999 03 11 08 18 39 0 System Diagnostic Started E 1999 03 11 08 18 37 0 System Diagnostic Ended E 199...

Страница 60: ...m Event Occurs LAN Link Down A LAN Admin Down A RF Link Down Manual E This event occurs when someone has manually set the Link Up Down field to be Down This event is cleared when the field is restored...

Страница 61: ...Addr 0 0 0 0 Target Timeout seconds 0 Count 0 Start_Ping Stop_Ping Loopback Tests T1 Ch 1 DISABLE T1 Ch 2 DISABLE System DISABLE Apply_Loopback BER Tests Channel T1_Ch1 Test Mark Time 0 Errors 0 Rate...

Страница 62: ...ocal Remote ODU Version Boot ROM Firmware Hardware IDU Version SCNM Boot ROM 00 01g SCNM Software 00 01k DP Boot ROM 00 15 DP Software 00 16 Framer DEV 36 Hardware X11B Update Restore Defaults Device...

Страница 63: ...ould contact them directly for support Through Wavespan If you are still having problems after consulting this manual contact us at our Web site at http www wavespan com or send electronic mail to sup...

Страница 64: ......

Страница 65: ...Stratum 100 Installation and Maintenance Guide Appendix A Technical Specifications 57 Appendix A Technical Specifications...

Страница 66: ......

Страница 67: ...Stratum 100 Installation and Maintenance Guide Index 59 Index Error No index entries found...

Отзывы: