WIFI232-B2 User Manual
54
/
102
Figure 45 Search Module
C
lick “Search”, the text box will show the module searched, click module then you
can send command as COM.
5.1.2
Instruction Syntax Format
AT+ Instruction protocol is based on the instruction of ASCII command style, the
description of syntax format as follow
➢
Format Description
<>: The parts must be included
[ ]: The optional part
➢
Command Message
AT+: Prefix of command message
CMD: Command string
[op]: Symbol of command operator
“=”: The command requires parameters setting;
“NULL”: Query the current command parameters setting
[para-n]: Parameters input for setting if required
<
CR>: “Enter” Key, it is 0x0a or 0x0d in ASCII
Notes:
When input AT+ Instruction, “AT+
<CMD
>” character will display capital letter
automatic and other parts will not change as you input.
➢
Response Message
+<RSP>[op]ppara-1, para-2, para-3, para-4, para-4,
…]<CR><LF><CR><LF>
+: Prefix of response message
RSP: Response string;
“ok”: Success