485 TO ETH (B) User Manual
7
/
36
The parameters here are as follows:
1. Server upload time: The default JSON data is sent to the server every time. The server is
the destination IP set in the device configuration interface just now, and the unit is
milliseconds.
2. Add/View: After clicking, you can design every JSON node, or you can view the currently
designed content.
3. Delete all: Delete all Modbus registers designed by the "Add/View" button to facilitate the
restart of the design.
4. Save JSON settings: After the design is completed, only click this button to save the data
to the download directory just now, and then download it to the inside of the device.
Now click the "Add/View" button. For the first row of the previous Modbus table:
Register
address
Parameter name
Byte
length
Remarks
0
Current total active
energy
4
Unsigned,keep 2 decimal
places
The corresponding configuration is as follows:
Figure 5 Register settings