To achieve this, we provide the tripod horizontal extension (
WSNA0002
). The
fiber optic connection could also support in keeping the user farther from the
device. See accessories in Appendix 9.
Appendix 6.
E-field Measurement under Powerline
When measuring electric field below a power line, it is advisable to place the
SMP2
in horizontal and and be separated from the unit with a tripod or a wood
stick or extension.
In high frequency measurements, placing the device horizontally will increase
the LF (low frequency) immunity and obtain more accurate results.
For low frequency electric field measurements using the
WP400
and
WP50
probes, the body should not be close to the device. A person holding the
device during measurement would perturb the field. It is therefore advised that
the user places the device at a horizontal position and stays away from the
device (1.5 m minimum, 3 m recommended as per
IEC 62110
) to obtain more
accurate (unperturbed) results.
electrical
field
electrical
field
body currents
suitable placing
of your SMP2
User’s Manual
Electromagnetic Field Meter SMP2
P.