220
Transmission Modes
WAVECOM Decoder W74PC, W-PCI/e, W-CODE, W-CLOUD Manual V9.1.0
Parameter
Value
Frequency range
VHF/UHF
Operation modes
Analogue Selcal
Modulation
FM, SUB tone
Receiver settings
FM, BW = 12 kHz
Input format(s)
AF, IF
If more than two identical digits are to be transmitted, the repetition tone is appended to the digit tone
(e.g., 22222 is transmitted as f2 fw f2 fw f2, where f2 is the tone for "2" and fw is the repetition tone).
In most systems the accuracy of the single frequencies has to be 1/-1% of the nominal value.
Decoding the selective calls is started by clicking on a system. If transmission and system selection con-
form, the call sign is displayed on the monitor. In the
Options
menu a
Time stamp
function can be ena-
bled to add date and time to each call.
Tone Allocation
Digit
Hz
Digit
Hz
0
1981
8
1747
1
1124
9
1860
2
1197
A
1050
3
1275
B
930
4
1358
C
2400
5
1446
D
991
6
1540
E
2110
7
1640
Tone duration: 100 ms.
PDZVEI
The entire call number is transmitted by consecutive tones in decade sequence. When two identical digits
are to be transmitted consecutively, then an eleventh frequency is used as a repetition identifier.
Parameter
Value
Frequency range
VHF/UHF
Operation modes
Analogue Selcal
Modulation
FM, SUB tone
Receiver settings
FM, BW = 12 kHz
Input format(s)
AF, IF
If more than two identical digits are to be transmitted, the repetition tone is appended to the digit tone
(e.g., 22222 is transmitted as f2 fw f2 fw f2, where f2 is the tone for "2" and fw is the repetition tone).
In most systems the accuracy of the single frequencies has to be 1/-1.5% of the nominal value.
Decoding the selective calls is started by clicking on a system. If transmission and system selection con-
form, the call sign is displayed on the monitor. In the
Options
menu a
Time stamp
function can be ena-
bled to add date and time to each call.