background image

t +61 3 9239 2000
f +61 3 9561 2614

e

.intercel.com.au

Toll free number for

Wavecom Instruments Pty Ltd

257 Grange Road

Findon, South Australia 5023

Phone

: (+61) 08 8243 3500

Fax

: (+61) 08 8243 3501

Email

[email protected]

Website

: www.wavecom.com.au

ABN

 60 065 609 225

 

 
8. 

 

a.  Power supply : 

 
 

 

 

 

 

     GSM850/900 

GSM1800/1800 

 
Maximum Input current  

@ 5V   

2.1A 

 

1.88A 

Power=33.10dBm GSM850/900 
During 2Tx bursts @ Pcl5 

@ 13.2V 

1.4A 

 

1.1A 

Power=33.0dBm DCS1800/1900 
During 2Tx bursts @ Pcl0 

@ 32V  

610mA  

390mA 

 
Average Input current 

 

@ 5V   

500mA  

390mA 

Power=33.10dBm GSM850/900 
Average 3Rx/2Tx @ Pcl5 

@ 13.2V 

400mA  

160mA 

Power=33.0dBm DCS1800/1900 
Average 3Rx/2Tx @ Pcl0 

@ 32V  

95mA   

80mA 

 
Average input current in  

@ 5V   

34mA   

34mA 

idle mode, where RF active 
Modem synchronized with 

@ 13.2V 

18mA   

18mA 

Network but there is no 
communication  

 

@ 32V  

9mA 

 

9mA 

 
 

b.  RF band 

 
 

 

 

EGSM900 

DCS1800 

GSM850 

PCS1900 

 
Tx Frequency 

 

880-915MHz 

1710-1785MHz 824-849MHz 

1850-1910MHz 

Rx Frequency   

925-960MHz 

1805-1880MHz 869-894MHz 

1930-1990MHz 

 
Rx sensitivity 

 

-104dBm 

-102dBm 

-104dBm 

-102dBm 

Linear dynamic range 

63dB 

 

63dB 

 

63dB 

 

63dB 

Co-channel rejection 

≥9dBc

   

≥9dBc

   

≥9dBc

   

≥9dBc

 

 
Max Output Power 

33dBm±2dB 

30dBm±2dB 

33dBm±2dB 

30dBm±2dB 

Min Output Power 

5dBm±5dB 

0dBm±5dB 

5dBm±5dB 

0dBm±5dB 

Содержание SAM

Страница 1: ...NE MODEM WAVECOM SAM 2W User Guide WavecomInstruments Pty Ltd 257 Grange Road Findon South Australia 5023 Phone 61 08 8243 3500 Fax 61 08 8243 3501 Email office wavecom com au Website www wavecom com...

Страница 2: ...Safety Precautions 3 Radio frequency exposure SAR 4 WEEE directive 2002 96 EC 5 Packaging 6 Functionality a General b The RJ45 connector c The Data cable d The SIM holder e The LED status 7 Operation...

Страница 3: ...he SIM holder which allows users to monitor the status of the modem in operation The SAM is controlled using a set of standard AT commands 2 Safety Precautions The following safety precautions must be...

Страница 4: ...uency electromagnetic field The SAR value is determined at the highest certified power level in the laboratory conditions but the actual SAR level of the transceiver while operating can be well below...

Страница 5: ...3 Phone 61 08 8243 3500 Fax 61 08 8243 3501 Email office wavecom com au Website www wavecom com au 5 Packaging The SAM package consists of A SAM modem A data cable A one page Specification of the SAM...

Страница 6: ...vecom com au 6 Functionality a General The SAM modem is a Quad band 850 900 1800 1900MHz GSM GPRS modem It consists of an RJ45 connector for serial port and input power an FME male antenna connector a...

Страница 7: ...one 61 08 8243 3500 Fax 61 08 8243 3501 Email office wavecom com au Website www wavecom com au b The RJ45 connector Pin Signals Description 1 VIN Input voltage 5Vdc 32Vdc 2 DCD Data Carrier Detect 3 D...

Страница 8: ...he Data cable The data cable is 2m long It consists of an RJ45 plug a DB9 female connector and a 2 wire input power 5 4 3 2 1 9 8 7 6 DB9 Signals RJ45 Description 1 DCD 2 Data Carrier Detect 2 RXD 5 S...

Страница 9: ...e www wavecom com au The SIM holder The SIM holder takes the 3V mini SIM card only To insert the SIM card remove the door by sliding it back toward the end Make sure the SIM card faces the right way a...

Страница 10: ...sed as a guide For the complete set of AT commands refer to the AT command manual The AT command to the SAM always starts with AT and ends with CR Carriage Return The response from the SAM starts and...

Страница 11: ...a call ATDn nn cr Make a data call to a data number CONNECT 115200 Connected Data transfer back and forth Back to command mode ATH Hang up data call Receive a data call RING Incoming call received ATA...

Страница 12: ...0mA Power 33 10dBm GSM850 900 Average 3Rx 2Tx Pcl5 13 2V 400mA 160mA Power 33 0dBm DCS1800 1900 Average 3Rx 2Tx Pcl0 32V 95mA 80mA Average input current in 5V 34mA 34mA idle mode where RF active Modem...

Страница 13: ...y range Quad band GSM 850 900 1800 1900MHz Impedance 50 VSWR Rx Max 1 5 1 Tz Max 1 5 1 Typical radiated Gain 0dBi d Temperature Operating temperature 20 C to 55 C Storage temperature 25 C to 70 C e Co...

Страница 14: ...ipped with a computer connected to a landline PSTN modem or another SAM2W modem To read the remote meter the Operator uses the computer and the connected modem and calls the SAM2W at the remote site T...

Страница 15: ...me common errors Error code Error meaning Hint 0 Modem failure Call technical support 3 Operation not allowed 4 Operation not supported 10 SIM not inserted Check SIM card clean contacts 11 SIM PIN req...

Страница 16: ...eater than 12 is sufficient e Care and maintenance The GSM modem is an advanced piece of engineering equipment and should be treated with care The suggestion below will help to prolong the modem s lif...

Страница 17: ...Max Min Max 880 915 1710 1785 Max power density S f 200 W m 4 400 4 575 8 550 8 925 Power to the antenna W 2 2 1 1 Norminal antenna gain dB 0 0 0 0 Norminal antenna gain G 1 1 1 1 Distance from the an...

Страница 18: ...m does not have an integral antenna Depending on customers requests the SAM2W modem may may not be supplied with an antenna In the cases of customers wanting to acquire the antennas themselves the ant...

Отзывы: