wattstopper WN-100 Скачать руководство пользователя страница 2

UNIT DESCRIPTION

The Watt Stopper

WN-100 is a motion sensing wall switch and nightlight that

controls lighting based on occupancy. The sensor uses passive infrared (PIR)
technology to sense human motion in a controlled space. It must have a clear
view of occupants in the space in order to detect occupancy. Obstructions such
as furniture blocking the sensor’s lens may prevent occupancy detection.
Note: Windows, glass shower doors, etc. will obstruct the WN-100’s view and

may prevent detection.

Through the WN-100’s mode selection, the user can specify ON functions and
time delay (see Sensor Adjustment & Programming section).

OPERATION

ON-Mode Functions (Manual-ON & Automatic-ON):

Manual-ON:

When the WN-100 is set to Manual-ON, users must turn lights on by pushing
the ON/OFF button. Lights will not turn on automatically with occupancy in
the Manual-ON mode. However, for a grace period of 30 seconds after
shut-off, the WN-100 will turn the load back on automatically when motion is
detected.

Automatic-ON:

In Automatic-ON mode, the WN-100 automatically turns lights on when a
designated space becomes occupied.
Note: In both Manual-ON and Automatic-ON, the ON/OFF button turns lights

off. The ON/OFF button must be pressed again to turn lights back on.

Time Delay:

The WN-100 automatically turns lights off after a space becomes vacant and
a preset time interval, or time delay, elapses. If lights are left on and no
motion is detected for the time delay selected (factory default = one hour), the
WN-100 automatically turns lights off.

Nightlight:

In the factory default mode, the nightlight remains on whenever the load is
off, regardless of occupancy.
The nightlight can be disabled from constant illumination (see “End User
Options” in the Sensor Adjustment & Programming section). However, when
motion is detected by the WN-100 while in Manual-ON mode, the nightlight
will automatically turn on and remain on until 90 seconds after the room
becomes vacant again. In this situation, nightlighting is provided only when
the room is in use.
If the nightlight remains disabled for 48 hours, it will automatically switch to
the default (enabled) mode.

Содержание WN-100

Страница 1: ...cent and Compact Fluorescent Horsepower Rating 1 6 HP WN 100 277 Voltage 277VAC 60Hz Power Consumption 0 92W maximum Load Requirements 800W Fluorescent General Time Delay Adjustment Fixed 15 minute 30 minute 1 hour 2 hour Operating Temperature Range 32 131 F 0 55 C Operating Humidity Range 95 RH non condensing Installation Instructions US Patent Number 4 787 722 ...

Страница 2: ...y when motion is detected Automatic ON In Automatic ON mode the WN 100 automatically turns lights on when a designated space becomes occupied Note In both Manual ON and Automatic ON the ON OFF button turns lights off The ON OFF button must be pressed again to turn lights back on Time Delay The WN 100 automatically turns lights off after a space becomes vacant and a preset time interval or time del...

Страница 3: ...aintain its coverage capacity and optimally detect motion the WN 100 must have a clear and unobstructed view 4 0 1 2m 25 7 6m floor Hot Black Neutral White Load Load Red Neutral White TOP INDOOR USE ONLY ON 1 Ground Green Single sensor wiring 25 7 6m 10 3 1m WIRING Visit our website for FAQs www wattstopper com ...

Страница 4: ... allow any bare wire to show above the connector 3 Attach the sensor to the wall box by inserting screws into the two wide holes on the top and bottom of the attached metal bracket Line them up with the holes in the wall box and tighten 4 Turn on the circuit breaker Push the ON OFF button and the lights will turn on TOP INDOOR USE ONLY TOP INDOOR USE ONLY Insert or wrap wire as shown Tighten screw...

Страница 5: ...n the WN 100 will operate in Test Mode for five 5 minutes During this period the time delay will be 15 seconds and the WN 100 will operate as Automatic ON After five 5 minutes the WN 100 will use the parameters of the selected mode Note Do not leave the Program Mode Switch in the UP Program position The WN 100 will only operate properly in the DOWN End User position Mode Selections Flashes Time De...

Страница 6: ...tion The load should turn off within 15 seconds and the nightlight should subsequently turn on Repeat as necessary to ensure that the desired coverage areas are within detection range Lights will not turn on nightlight is illuminated 1 Press ON OFF button lights should turn on If not check sensor wire connections to the load 2 Check the lamp Lights will not turn on nightlight is NOT illuminated 1 ...

Страница 7: ...G INFORMATION WARRANTY INFORMATION Watt Stopper Legrand warranties its products to be free of defects in materials and workmanship for a period of five 5 years There are no obligations or liabilities on the part of Watt Stopper Legrand for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property rev...

Отзывы: