background image

INSTALLATION & WIRING

WARNING

 

Disconnect power to the wall switch box by turning OFF the circuit  

breaker or removing the fuse for the circuit before installing the  

RT-50, replacing lamps, or doing any electrical work.

1.  Prepare the switch box.

  After the power is turned OFF at the circuit 

breaker box, remove the existing wall plate and 

mounting screws. Pull the old switch out from the 

wall box.

2.  Identify the type of circuit.

  In a Single Pole Circuit (see Fig. 1), two single 

wires connect to two screws on the existing 

switch. A ground wire may also be present 

and connected to a ground terminal on the old 

switch. A neutral wire should also be present in 

the wall box.

CAUTION 

For your safety: Connecting a proper ground to the time switch provides 

protection against electrical shock in the event of certain fault conditions. 

If a proper ground is not available, consult with a qualified 

electrician before continuing installation.

Only connect the RT-50 to a Single Pole Circuit. 

The RT-50 is not suitable for 

3-way switching. If the existing wiring does not match the description for a Single 

Pole Circuit, you should consult with a qualified electrician.

3.  Prepare the Wires.

  Tag the wires currently connected to the existing 

switch, so that they can be identified later. 

Disconnect the wires. Make sure the insulation 

is stripped off the wires to expose their copper 

cores to the length indicated by the “Strip Gage,” 

in Fig. 2 (approximately 1/2 inch).

4.  Wire the time switch.

  Twist the existing wires together with the wire leads on the time switch as 

indicated in the drawing. Cap them securely using the wire nuts provided. See 

Fig 3.

•  Connect the green or 

non-insulated (copper) 

GROUND wire from the 

circuit to the GROUND 

terminal on the RT-50.

•  Connect the power wire 

from the circuit (HOT) 

to the black wire on the 

RT-50.

•  Connect the power wire 

to the lamp or fan (LOAD) 

to the red wire on the 

RT-50.

•  Connect the NEUTRAL 

wires from the circuit 

to the white wire on the 

RT-50.

5.  Put the RT-50 in 

the wall box with 

the time selection 

buttons positioned 

above the ON/OFF 

button. 

  Secure it to the wall box with 

the screws provided.

6. Install cover plates. 

  Install industry standard decorator wall switch cover plate (not included).

7. Restore power to the circuit.

  Turn on the breaker or replace the fuse.

www.wattstopper.com

*URXQG

+27SRZHUIURP

FLUFXLWER[

/2$'

SRZHU

WRODPS

1(875$/

Fig. 1: Typical Single 

Pole Switch 

Wiring

TOP

INDO

OR U

SE O

NLY

Green 

-> 

 GROUND

Terminal

Black 

-> 

HOT (power

from circuit box)

Y

Y

White 

->

 

        NEUTRAL

Red 

->

 LOAD (power

to lamp or fan)

Industry standard 
switch cover plate
(not provided)

Fig. 3: Switch orientation, wire connections 

and wall box assembly

Strip Gage

1/2"

12.7 mm

Fig. 2: Wire Stripping

Содержание RT-50

Страница 1: ... Manual OFF While a timer is active you can press the ON OFF button to turn OFF the connected light or fan without delay Changing the selected time If you decide that you need more or less time than you originally selected restart the time switch by pressing the button that matches the amount of time you think you ll need RT 50 Time Switch 7 Button Preset SPECIFICATIONS Voltage 120VAC 60HZ Load Si...

Страница 2: ...hey can be identified later Disconnect the wires Make sure the insulation is stripped off the wires to expose their copper cores to the length indicated by the Strip Gage in Fig 2 approximately 1 2 inch 4 Wire the time switch Twist the existing wires together with the wire leads on the time switch as indicated in the drawing Cap them securely using the wire nuts provided See Fig 3 Connect the gree...

Страница 3: ...k the light bulb and or motor switch on the fan mechanism Make certain that the circuit breaker is ON and functioning Turn OFF power to the circuit then check wire connections Call 1 888 817 0571 for technical support Light or fan will not turn OFF Press the ON OFF button If connected light or fan does not turn OFF turn OFF power to the circuit then check wire connections COVER PLATES WattStopper ...

Страница 4: ...tivo usted puede oprimir el botón de Encendido Apagado para apagar sin retardo la lámpara o ventilador conectado Cambio del tiempo seleccionado Si usted decide que necesita más o menos tiempo con respecto al tiempo seleccionado originalmente reinicie el interruptor temporizado oprimiendo el botón de selección de Retardo de Apagado que coincide con la cantidad de tiempo que usted cree que se necesi...

Страница 5: ...onecte los alambres Asegúrese de remover el aislamiento de los alambres para exponer sus núcleos de cobre según la longitud indicada en la Figura 3 aproximadamente 1 2 pulg 4 Cablee el interruptor temporizado Empalme retorciendo los alambres existentes con los alambres del interruptor temporizado según se indica en el diagrama Fíjelos de manera firme utilizando los conectores wire nuts para alambr...

Страница 6: ...cadora de Retardo de Apagado Haga sombra sobre el interruptor para asegurarse que ninguna de las luces indicadoras del interruptor esté encendida Revise la bombilla y o el interruptor del motor en el mecanismo del ventilador Verifique que el cortacircuitos breaker esté encendido y funcionando Apague el suministro eléctrico hacia el circuito luego revise las conexiones de los alambres Llame al telé...

Отзывы: