 Catalog # 

Description

  FS-PP v2 

Fixture Mount Power Pack: 120/277/347VAC, 60Hz

 

 

with NO/NC Relay output

  FS-105 

 Ceiling tile mount, low voltage PIR occupancy sensor

 

with adjustable time delay and light level

  FS-205 

 Fixture mount, low voltage PIR occupancy sensor

 

with adjustable time delay and light level

  FS-305 

 Fixture or Ceiling tile mount, low voltage PIR occupancy sen

-

sor, adjustable time delay

  FS-405 

Fixture mount, low voltage PIR occupancy sensor w/20’

 

 

diameter coverage, adjustable time delay and light level

  FS-505 

 Fixture mount, low voltage ultrasonic occupancy sensor

  FS-505C 

Same as FS-505, with directional cones

  FS-C1 

 One 10’ cable with a shielded RJ45 male connector at each 

end

  FS-C2 

One 6” (152mm) cable with 3 flying leads at

 

 

one end and a shielded RJ45 male connector 

 

 

at the other

  FS-C3 

One 3’ cable with a 

 

 

shielded 90° RJ45 

 

 

male connector at one end and a shielded straight male 

 

 

RJ45 connector at the other end, for space-limited areas

  FS-C4 

Shielded RJ45 splitter with female to dual

 

 

female receptacles

  FS-C5 

Shielded RJ45 male-to-male coupler

ORDERING INFORMATION

  Sensors and power packs are White.

WARRANTY INFORMATION

Watt Stopper  warranties its products to be free of defects in materials 

and workmanship for a period of five (5) years. There are no obligations or 

liabilities on the part of Watt Stopper for consequential damages arising out 

of, or in connection with, the use or performance of this product or other 

indirect damages with respect to loss of property, revenue or profit, or cost of 

removal, installation or reinstallation.

2800 De La Cruz Boulevard, Santa Clara, CA 95050

 

800.879.8585 

 

www.wattstopper.com

 

03391r5  4/2012

10' (3m)

6" (152mm)

3' (914mm)

Содержание FS-PP v2

Страница 1: ...AC 60Hz Relay Type Form C with Zero Crossing on N O only Output 70mA 24VDC with relay connected Load Requirements 120VAC 5 0A N O 3 0A N C 1 6hp 277VAC 4 3A N O 2 5A N C 1 6hp 347VAC 3 4A N O 2 0A N C Low Voltage Connections RJ45 connection to FS sensors Control in common 24VDC Line and Load Connections 12 18AWG screw terminals Terminal Torque Rating 4 428 inch pound force 0 5Nm Operating Temperat...

Страница 2: ...N 1 Determine an appropriate mounting location inside the light fixture 2 Use the holes or mounting slots at both ends of the power pack to secure it to the fixture 3 Connect wires to load as described in the wiring section 4 Connect wires to electrical supply as described in the wiring section 5 Connect the RJ45 from the sensor to the RJ45 on the power pack 6 Restore power from the circuit breake...

Страница 3: ...g from FS sensor Neutral Santa Clara CA 800 879 8585 FS PP V2 Model Fixture Sensor Power Pack 120 277 347VAC 60Hz 120VAC 5A N O 3A N C 277VAC 4 3A N O 2 5A N C 347VAC 3 4A N O 2A N C GROUND NEUTRAL LINE 03392r2 Strip Gauge 12 18AWG CU wire only 88T9 Appliance Control LISTED AC INPUT Santa Clara CA 800 879 8585 FS PP V2 Model Fixture Sensor Power Pack 120 277 347VAC 60Hz 120VAC 5A N O 3A N C 277VAC...

Страница 4: ...FS C1 10 FS C4 FS C3 3 or FS C1 10 shown FS C4 FS C4 FS C3 3 or FS C1 10 shown FS PP FS PP FS PP FS PP FS PP FS PP Any 24VDC FS Sensor Any 24VDC FS Sensor Any 24VDC FS Sensor Any 24VDC FS Sensor Any 24VDC FS Sensor Any 24VDC FS Sensor Fig 6 One sensor controlling two Power Packs CONTROL CONFIGURATIONS Fig 7 Two sensors controlling one Power Pack Fig 8 Two sensors controlling two Power Packs Fig 5 ...

Страница 5: ... do not turn on call 800 879 8585 for technical support Lights will not turn off The time delay can be set from 30 seconds to 30 minutes Ensure that the time delay is set to the desired delay and that there is no movement within the sensor s view for that time period To quickly test the unit for proper operation turn the time delay to minimum and move out of the sensor s view Lights should turn of...

Страница 6: ...t one end and a shielded RJ45 male connector at the other FS C3 One 3 cable with a shielded 90 RJ45 male connector at one end and a shielded straight male RJ45 connector at the other end for space limited areas FS C4 Shielded RJ45 splitter with female to dual female receptacles FS C5 Shielded RJ45 male to male coupler ORDERING INFORMATION Sensors and power packs are White WARRANTY INFORMATION Watt...

Отзывы: