e)  Tighten bottom clamp evenly. (Brackets 

should be p arallel). 

f) 

Turn handle clockwise to close the valve. 

g)  Connect ¼” green tubing from the unit to 

the Self-Piercing Valve as shown in figure 
C. Failure to do this before piercing the tube 
will cause a small amount of water to escape 
from the outlet. 

h)  Turn on water supply and open the tapping 

valve by turning the handle counter 
clockwise.  

i) 

Check for leaks and repair if any.

 

 

Figure C  

 
 
 
 
 
 
 
 
 
 
 
 

Processor B 

Installing Easy Tap Adapter 

Cold Water Supply Only 

 

Easy tap adapter to be installed on ½” male pipe 
thread connection before angle stop valve or onto 
the faucet. Note: If your plumbing does not 
allow for connection of easy tap adapter contact 
your local plumbing or hardware store for 
modifications.  

(a) 

Turn off the supply water. The Easy 
Tap Adapter may be installed before 
angle stop valve (as shown in figure 
C1), or installed at the faucet (as 
shown in figure C2).

 

Note: Plumbing connections maybe reversed 
from drawing below. 

 
Figure C1 

 

 
 
 
 
 
 

 
 

 
 
 
 
 

Figure C2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(b)  Teflon tape the 1/8” male pipe thread of the 

easy tap valve and screw into easy tap valve 
body. 

(c)  Disconnect the fitting where the easy tap 

valve is to be installed. 

Note: When 

loosening or tightening fitting use 
wrenches on both sides of fittings.   

 

(d)  Insert the easy tap gasket into the female 

thread side of easy tap. No plumber putty or 
Teflon tape is required on thread. 

(e)  Thread easy tap valve on to the ½” male 

pipe threads and tighten securely with 
wrenches

. Note: Use wrenches on both 

sides of the connections.

  

(f)  Thread angle stop valve or plumbing line to 

the other end of the  easy adapter valve and 
tighten securely using wrenches. 

(g)  Connect green tubing from unit to the easy 

tap valve (as shown in figure C1 or C2). 

(h)  Turn handle clockwise making sure that 

easy tap valve is in the closed position. 

 

Brass nut

Delrin Sleeve 

Brass Insert

Valve Handle

3/8” cold water line

1/4” green tubing

Lance

Rubber Gasket

For water line sizes greater than 3/8”

Sink faucet

Gasket

Easy Tap
Valve

1/2” connection
plumbing from
angle stop

Brass insert

Delrin sleeve

Brass Nut

Tubing

Gaske

Easy 

Tap 

Angle

Stop 

Nut

Tubin

Delrin  
Sleeve

Brass
insert

Plumbing 
connection
sink faucet

Содержание WM-120-PT

Страница 1: ...th water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Revised October 2002 Watts Pure Water Inc 1725 W Williams Dr C 20 Phoenix AZ 85027 623 505 1512 Office 602 588 0356 FAX www wattspurewater com Premier Water Systems ...

Страница 2: ... Water in Phoenix Arizona U S A 888 774 7405 Figure 1 Shut off valve Inlet ball valve Flush ball valve Flow Restrictor Note Ball valves shown in closed position WM 120 Polyethylene tubing is color coded for easy installation a OD Green Polyethylene tubing to be connected to a cold water feed supply b OD Black Polyethylene tubing is for flushing of pre filters and requires no connection c 3 8 OD Re...

Страница 3: ...th Final polishing filter Pressure Storage Tank Ordered separately 1 4 blue tubing to storage tank WM 120 PT General plumbing layout For use with Steam Equipment To drain To equipment Note Tee on bottom port of tank 1 4 black tubing Flush 1 4 green tubing Incoming feed water supply Final Carbon Calcite filter Ordered separately Pressure Storage Tank Ordered separately 1 4 blue tubing to storage ta...

Страница 4: ...lve or Easy Tap Adapter WM 120 supplied with a Self Piercing Valve follow Processor A WM 120 supplied with an Easy Tap Adapter follow Processor B Processor A TO INSTALL SELF PIERCING VALVE ON COPPER TUBE CAUTION Do not turn handle before or while installing Self Piercing Valve be sure the piercing lance does not protrude beyond the rubber gasket Failure to do this may result in damage to the pierc...

Страница 5: ...Figure C2 b Teflon tape the 1 8 male pipe thread of the easy tap valve and screw into easy tap valve body c Disconnect the fitting where the easy tap valve is to be installed Note When loosening or tightening fitting use wrenches on both sides of fittings d Insert the easy tap gasket into t he female thread side of easy tap No plumber putty or Teflon tape is required on thread e Thread easy tap va...

Страница 6: ...e must be reduced The air pressure setting in a pressurized storage tank should be checked and set between 7 to 10 psi when the tank is empty of water for correct operation of the WM 120 PT The blue plastic tubing is the line the RO water flows through from the WM 120 The blue tubing connects to a pressurized storage tank or post treatment equipment depending on the application NOTE Adding ball va...

Страница 7: ...feeding into the storage tank g Turn on water supply to RO unit and allow WM to produce water for 2 hours h If you have ball valve after the storage tank or before the post filter housing you may shut the RO water supply off at that point i Open faucet at the furthest point from storage tank to depressurize Ro water lines Add post filter cartridge back to its filter housings j Close faucet and ope...

Страница 8: ... 10 Elbow Plastic C x M 90o 3 Inlet Feed Ball Valve Brass F 11 Automatic Shut Off Valve 4 0 100 Pressure Gauge M Bottom Mount 12 Membranes Pressure Vessel 2 5 Filter Housing 20 Blue 3 13 Check Valve Elbow Plastic C x M 90o 2 6 0 100 Pressure Gauge M Bottom Mount 14 Flow Restrictor 850 ml 7 Flush Ball Valve Brass F 15 Drain Line 3 8 Red Plastic Tubing 15 feet 8 Flush Tubing Black 6 feet 16 Permeate...

Отзывы: