background image

Watts TK-DL Software Instructions

The Watts TKDLC102 Software Disc is menu driven and will prompt you throughout the process of down loading your Watts 
TK-DL test results to a personal computer.  The following information has been provided to assist you in utilizing your Watts 
TK-DL test kit.

TK DLC 102: Enter

READ WRITE TO TESTER: Enter

Connect TK-DL to computer and turn on 
(on screen instructions)

A.

  Load Data from Tester

 

 

Reads Tester information in memory.

B.

 Display 

settings

 

 

Model = Watts TK-DL

  Eprom 

Version

  Serial 

#

  Time/Date
  Last 

Calibrated

  Next 

Cal 

Due

  Next 

Test 

#

C.

 Change 

Settings

 

 

Time/Date - day only

D.

  Display Heading and Footer

 

 

Displays heading and footer in TK-DL

 

 

memory printed on tape.

E.

  Change Heading and Footer

 

 

Allows heading and footer to be changed

 

 

by using computer keyboard.

F.

 

Write Data to Tester (Saves information to the 

 

Test Kit once you have changed the header or 

 

the footer or anything in the “Change Settings” 

 option).

G.

  Load Heading File

 

 

It recalls a heading that was previously 

 

 

saved.  You can then load into the TK-DL 

 

 

when you are connected to the computer.  

 

 

After loading you must write data to tester 

  (Step 

F).

H.

  Load Footing File

 

 

Same as load heading, except for footer.

G., H.

 Brings up headers and footers that were pro-

 

grammed and saved at an earlier time.  You may 

 

recall the footer or header to program into you test 

 

kit.  The recalled or “Loaded” information will 

 

overwrite current information.

I.

 Save 

Heading

J.

 Save 

Footing

I, J,

 Use this option when you have changed the header 

 

or the footer and want to save the changes.  You 

 

can save each header and footer in a separate fi le.  

 

You can then recall or “Load” the header or footer to 

 

be programmed into your test kit.

K.

  Down Load Tests

 

 

Down loads from TK-DL to disc.

L.

 Print 

Tests

  On 

screen 

prompts:

 

 

 

F2 OK, F4 scroll up, F6 scroll on,

   Esc 

to 

cancel.

 

 

 

Lists date and Time tests

   were 

recorded.

 

 

 

     to select test to print

 

Note:

 The disc included with your test kit allows you 

 

to change your header or footer.  Therefore, the disc 

 

should not be carried in the test kit case.

 

 

 

IS-TK-DL   0829 

EDP# 1910763

 

© Watts, 2008 

USA:

  815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com

Canada:

  5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

B a c k f l o w   P r e v e n t i o n   P r o d u c t s

IS-TK-DL.indd   8

9/5/08   2:18:59 PM

Содержание TK-DL

Страница 1: ...COMPANY MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty and the Company shall not ...

Страница 2: ...then TC 2 Bleed hose then close VA 3 Close shutoff valve 2 then 1 Push Print Head wait then Push Start Test 4 Slowly open VA when air inlet float opens push hold but ton for at least 2 seconds Record differential reading must be 1 PSID or more Close VA Push Stop Test 5 Close TC 2 and remove hose 6 Open shutoff valve 1 Test No 2 Test Check Valve 7 Install highside hose between TC 1 and tester connec...

Страница 3: ...hree turns 8 When dripping from bleed screw stops and gauge reading settles this is the check differential This must be 1 PSI or greater 9 Press PAUSE STOP button Test No 2 Air Inlet Vent Opening 10 Press START TEST RESUME 11 Slowly open VA and watch vent with finger over DISPLAY HOLD button When the water level above the vent starts to drop this is the vent opening press DISPLAY HOLD button This w...

Страница 4: ...ecord as tight If reading returns to 0 and the pressure A increases to pressure B the check is recorded as leaking If the reading returns to PSID No 2 shutoff valve is leaking excessively and must be replaced to test the valve 8 Close all test cocks remove hoses from TC 2 and TC 3 and TC 1 reopen shutoff valve 1 Proceed to Test No 2 Push Stop Test Test No 2 Test No 2 Check Valve 1 Install high sid...

Страница 5: ...ed air by loosening hose connection at VA Tighten hose connection and close VB Push Print Head wait then Push Start Test 7 Open VA then slowly open VB no more than 1 4 turn When relief valve drips push the hold button for 2 seconds Record reading must be 2 PSID or more Push Stop Test 8 Close VA and VB Test No 2 Test No 2 Check Valve 9 Install bypass hose between VA and TC 4 Open VA then bleed air ...

Страница 6: ...ssemble and replace seat o ring d Damaged guide holding Disassemble clean or replace check open e Weak or broken spring Disassemble and replace spring 2 Chatter during flow a Worn damaged or Disassemble and repair or conditions defective guide replace guide 3 Low flows passing a Mainline check fouled Disassemble and clean through mainline valve 709DCDA only b Meter strainer plugged Disassemble and c...

Страница 7: ... valve seat or inlet cover Install dielectric unions Watts Series 3001 through 3006 Electrically ground the piping system and or electrically isolate the device with plastic pipe immediately upstream and downstream of the device B 6 Valve improperly reassembled No B 6 If valve is diassembled during installation caution must be exercised to install check springs in their proper location C Valve exh...

Страница 8: ...ou can then load into the TK DL when you are connected to the computer After loading you must write data to tester Step F H Load Footing File Same as load heading except for footer G H Brings up headers and footers that were pro grammed and saved at an earlier time You may recall the footer or header to program into you test kit The recalled or Loaded information will overwrite current information...

Отзывы: