Description

INTERNET UNAVAILABLE

The thermostat has a WiFi connection to the router but is unable to communicate 

to the internet. Steps to clear the error include: 1) power off and on the router, 2) 

power off and on the thermostat. 

MEMORY ERROR

The thermostat memory settings are corrupted. To clear, load the factory defaults 

in the Toolbox menu. The thermostat will not operate any heating equipment 

while this error message is present.

INTERNAL ROOM SENSOR FAULT

Due to an open or short circuit, the thermostat is unable to read the internal room 

temperature sensor. If sensor 1 or 2 is set to room the thermostat continues to 

operate, otherwise operation stops. 

The error cannot be field repaired. Contact your tekmar sales representative for 

warranty or repair procedures.

SENSOR 1 FAULT

Due to an open or short circuit, the thermostat is unable to read the sensor wired 

to S1 and Com. The thermostat stops normal operation if sensor 1 is the only 

active room or floor sensor or if a floor maximum temperature has been set.

Check the auxiliary sensor wire for short circuits according to the sensor installa-

tion manual. It may be necessary to replace the auxiliary sensor. Once the error 

has been corrected, the error message automatically clears.

SENSOR 2 FAULT

Due to an open or short circuit, the thermostat is unable to read the sensor wired 

to S2 and Com. The thermostat stops normal operation if sensor 2 is the only 

active room or floor sensor or if a floor maximum temperature has been set.

Check the auxiliary sensor wire for short circuits according to the sensor installa-

tion manual. It may be necessary to replace the auxiliary sensor. Once the error 

has been corrected, the error message automatically clears.

ROOM HOT WARNING

The room temperature is above the Room Hot Warning setting in the Alerts 

menu. The warning will automatically clear once the room temperature falls 

below the setting. 

ROOM COLD WARNING

The room temperature is below the Room Cold Warning setting in the Alerts 

menu. The warning will automatically clear once the room temperature rises 

above the setting. 

When an error occurs an email notification will be sent to the registered tekmar 

Connect mobile or web app account owner.

Error Messages

Содержание Tekmar WiFi Thermostat 561

Страница 1: ...Installation Manual WiFi Thermostat 561 Compatible With 1 stage heating Supports optional floor sensor for radiant floor heating applications ...

Страница 2: ...3 8 Application 561 4 9 Sequence of Operation 10 Heating Operation 10 User Interface 11 User Settings 12 Away 12 Schedule 12 Display 13 Time 14 WiFi 15 Installer Settings 16 Setup 16 Setup Toolbox 16 Setup Temp 17 Setup Sensors 18 Setup Alerts 18 Setup Relays 18 Watts Home App 19 Error Messages 21 Technical Data 23 Limited Warranty and Product Return Procedure 24 Table of Contents ...

Страница 3: ...r moderate injury This symbol identifies practices actions or failure to act which could result in property damage or damage to the equipment Read Manual and all product labels BEFORE using the equipment Do not use unless you know the safe and proper operation of this equipment Keep this Manual available for easy access by all users Replacement Manuals are available at tekmarControls com It is the...

Страница 4: ...trol Relative Humidity less than 90 Non condensing environment No exposure to extreme temperatures beyond 32 122 F 0 50 C No draft direct sun or other cause for inaccurate temperature readings Away from equipment appliances or other sources of electrical interference Easy access for wiring viewing and adjusting the display screen Approximately 5 feet 1 5 m off the finished floor The maximum length...

Страница 5: ... being worked on turned off Please be aware local codes may require this thermostat to be installed or connected by an electrician Thermostat Front Thermostat Base Stud Switch Box 3 1 4 83 mm While holding the base section in one hand pull the lower half of the display front towards you to pivot it away from the base Wall Stud Thermostat Front Thermostat Base Removing The Thermostat Base Mounting ...

Страница 6: ...ve Control 304V or 306V B1 BP PS V1 T1 ZVC1 ZVC1 Mechanical Electrical The WiFi Thermostat 561 operates a radiant floor heating system The thermostat uses the built in air temperature sensor WiFi Thermostat 561 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W Application 561 1 ...

Страница 7: ... Control 304V or 306V ZVC1 B1 BP PS V1 S1 T1 ZVC1 Mechanical Electrical The WiFi Thermostat 561 operates a radiant floor heating system based upon the floor temperature sensor The built in air sensor is disabled WiFi Thermostat 561 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W Application 561 2 ...

Страница 8: ...ture sensor can be either built in and or external B1 BP PS V1 S1 S2 T1 ZVC1 Legend ZVC1 WiFi Thermostat 561 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W B1 Boiler BP Boiler Pump PS System Pump T1 WiFi Thermostat 561 S1 Floor Sensor 079 S2 Optional Indoor Sensor 084 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V Application 561 3 ...

Страница 9: ...nsor can be either built in and or external B1 BP PS V1 S1 T1 ZVC1 ZVC1 WiFi Thermostat 561 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W Legend B1 Boiler BP Boiler Pump PS System Pump T1 WiFi Thermostat 561 S1 Optional Indoor Sensor 084 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V Application 561 4 ...

Страница 10: ... minimum and maximum settings are available For a combination of air and floor temperature control leave the internal air sensor on in the setup menu A floor minimum can be used to prevent a fast drop in temperature caused by receding solar exposure This operation is recommended for areas heated by afternoon sun through large windows When the sun sets it can take a long time for the floors to get ...

Страница 11: ...rature to the current schedule event Go to settings Swipe to view Weather Outdoor temperature Floor temperature Heat To setting Go to schedule After 60 seconds of inactivity the thermostat home screen displays only the time and the temperature Save Cancel Mode Off Heat Temperature Adjustment Hold Until 5 00 PM Save to Schedule 70 Heat To MENU SELECTION AWAY SCHEDULE DISPLAY TIME WIFI SETUP WIFI Co...

Страница 12: ...hedule Mon Tue Wed Thu Fri Info Set heating temperature Select skip if you don t want a temperature change Set schedule start time On Skip Wake Schedule Setup Mon Tue Wed Thu Fri 6 00 AM Heat to 70 Operates normally Operates using the Away temperature selected in the Setup menu Use the Away setting to save energy when the building is unoccupied The Away temperature can be adjusted in the Setup Tem...

Страница 13: ...reen 30 to 100 100 BRIGHTNESS INACTIVE Select the brightness when not in use Off 30 to 100 50 BACKGROUND Select the background color Light Blue Night Latte Espresso Blue LANGUAGE Select the language English Español Français English SCREEN CLEAN Locks screen for 10 seconds to allow cleaning N A N A INACTIVE TIME DISPLAY Select if the time is visible when the display is inactive Off or On On INACTIV...

Страница 14: ...ndland Eastern DAYLIGHT SAVING TIME Select the brightness when not in use Off On On When connected to the Internet the time can be set automatically The time and date can be manually set by highlighting a field and then using the or buttons Choose from the time options listed below Incorrectly setting the time and date manually may prevent the thermostat from communicating to the mobile app Automa...

Страница 15: ...e Terms of Use available at https www watts com terms of use by pressing AGREE below Ifyoudonotaccepttheseterms this product can still be used without wi fi features WIFI NEXT Off On Time Source NEXT Automatic Manual NETWORK SSID CONNECT Select a network from the list Your House A C E B D F M O Q N P R Y A 1 Z Shft Del G I K H J L S U W T V X Enter Password CONNECT 1 3 5 2 4 6 A 1 Shft Del 7 9 8 0...

Страница 16: ...between user and installer access levels User access level restricts access in the Setup Menu User Installer Installer STATUS The current status of warm weather shut down cold weather shut down and each of the relays WWSD W1 N A SOFTWARE VERSION Display the software version J1249A N A LOAD DEFAULTS All settings are returned to factory defaults Yes No No CALIBRATE TOUCHSCREEN Recalibrate the screen...

Страница 17: ...is both a floor and an air sensor Off 40 to 95 F Off 4 5 to 35 0 C Off FLOOR MIN AWAY Select the floor temperature while in away Applies when there is both a floor and an air sensor Off 40 to 95 F Off 4 5 to 35 0 C Off FLOOR MAX Select the maximum floor temperature This protects the floor covering from over heating Applies when there is a floor sensor Off 40 to 95 F Off 4 5 to 35 0 C Off Screen Pa...

Страница 18: ...2 and Com wiring terminals Off Room Floor Outdoor Off INTERNAL ROOM SENSOR Select if the internal room temperature sensor is on or off Only available when Sensor 1 or 2 is set to read a room or floor sensor Off On On ROOM OFFSET Select if the internal room temperature sensor is on or off Only available when Sensor 1 or 2 is set to read a room or floor sensor Off 5 to 5 F 3 0 to 3 0 C Off FLOOR OFF...

Страница 19: ...ft Apple or long hold Android to edit the Location name Step 2 On the thermostat go to WiFi menu and press Register Device Step 5 Enter the 8 digit code from the thermostat into the mobile app Then enter the thermostat s room name The thermostat is now listed on the Devices page Add Thermostat to App REGISTRATION To finish registering your thermostat enter the code displayed below in the Watts Hom...

Страница 20: ...e temperature setting Limits Mode Current temperature Press Bars for settings Swipe left or long hold to edit or remove location Swipe left or long hold to edit or remove device Calendar alt Edit schedule Chart Line Energy use sync alt Refresh COG Thermostat settings Settings Locations Devices Thermostat ...

Страница 21: ...e has been set Check the auxiliary sensor wire for short circuits according to the sensor installa tion manual It may be necessary to replace the auxiliary sensor Once the error has been corrected the error message automatically clears SENSOR 2 FAULT Due to an open or short circuit the thermostat is unable to read the sensor wired to S2 and Com The thermostat stops normal operation if sensor 2 is ...

Страница 22: ...22 of 24 Page left intentionally blank ...

Страница 23: ... NEMA Type 1 Approvals Meets Class B ICES FCC Part 15 Ambient conditions Indoor use only 32 to 122 F 0 to 50 C RH 90 non condensing Power supply 15 to 30 V ac dc 2 VA standby Class 2 Relays 30V ac dc 2 A Class 2 circuits Sensor NTC thermistor 10 kΩ 77 F 25 C 0 2 C ß 3892 Included None Optional tekmar type 070 072 073 076 077 079 084 Communications WiFi 802 11n 2 4 GHz WPA2 encryption Mobile app Ap...

Страница 24: ...e Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation Pur chaser shall indemnify and hold tekmar harmless from and against any and all claims liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its ...

Отзывы: