manualshive.com logo in svg
background image

Limited Warranty 

The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any 

tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product 

sale and acknowledges that it has read and understands same.

The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through 
warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each 
tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used 
in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is 
for a period of twenty-four (24) months from the production date if the Product is not installed during that period, 
or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from 
the production date.

The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts 
and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the 
exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the 
original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from 
tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product 
liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, sec-
ondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship 
or materials, including any liability for fundamental breach of contract.

The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty 
period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective 
Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s 
agreement and warranty with its customers.

Any representations or warranties about the Products made by Purchaser to its customers which are different from 
or in excess of the tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Purchaser shall 
indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or 
nature which arise out of or are related to any such representations or warranties by Purchaser to its customers.

The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by 
persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, 
alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the 
Product was not installed in compliance with tekmar’s instructions and / or the local codes and ordinances; or if 
due to defective installation of the Product; or if the Product was not used in compliance with tekmar’s instructions.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW 
ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE PRODUCT, 
ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VI-
OLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER 
WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EXTEND BEYOND 
TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED 
BY THE GOVERNING LAW. 

Product Warranty Return Procedure

 All Products that are believed to have defects in workmanship or materials 

must be returned, together with a written description of the defect, to the tekmar Representative assigned to the 
territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Repre-
sentative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, regarding 
a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact information 
regarding the appropriate Representative.

Need help? Go to our website or contact us.

watts.com/tekmar | [email protected] | 1-800-438-3903

IOM-T-560 - 2145

 

©2021 tekmar Control Systems Ltd.

Tel: 1-800-438-3903 • Fax: (250) 984-0815

 watts.com/tekmar

Warranty

Содержание tekmar 560

Страница 1: ...Thermostat 560 Compatible With 1 stage heating Supports optional floor sensor for radiant floor heating applications Installation Manual IOM T 560 ...

Страница 2: ...0 2 7 Application 560 3 8 Application 560 4 9 Sequence of Operation 10 Heating Operation 10 User Interface 11 User Settings 12 Away 12 Schedule 12 Display 13 Time 14 Installer Settings 15 Setup 15 Setup Toolbox 15 Setup Temp 16 Setup Sensors 17 Setup Alerts 17 Setup Relays 17 Error Messages 18 Technical Data 19 Limited Warranty and Product Return Procedure 20 Table of Contents ...

Страница 3: ...minor or mod erate injury This symbol identifies practices actions or failure to act which could result in property damage or damage to the equipment Read Manual and all product labels BEFORE using the equipment Do not use unless you know the safe and proper operation of this equipment Keep this Manual available for easy access by all users Replacement Manuals are available at tekmarControls com I...

Страница 4: ... than 90 Non condensing environment No exposure to extreme temperatures beyond 32 122 F 0 50 C No draft direct sun or other cause for inaccurate temperature readings Away from equipment appliances or other sources of electrical interference Easy access for wiring viewing and adjusting the display screen Approximately 5 feet 1 5 m off the finished floor The maximum length of wire is 500 feet 150 m ...

Страница 5: ...the circuit being worked on turned off Please be aware local codes may require this thermostat to be installed or con nected by an electrician Thermostat Front Thermostat Base Stud Switch Box 3 1 4 83 mm While holding the base section in one hand pull the lower half of the display front towards you to pivot it away from the base Wall Stud Thermostat Front Thermostat Base Removing The Thermostat Ba...

Страница 6: ...ay C R AWAY W Legend B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V B1 BP PS V1 T1 ZVC1 ZVC1 The Thermostat 560 operates a radiant floor heating system The thermostat uses the built in air tem perature sensor Mechanical Electrical Application 560 1 ...

Страница 7: ...B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 S1 Floor Sensor 079 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V ZVC1 B1 BP PS V1 S1 T1 ZVC1 The Thermostat 560 operates a radiant floor heating system based upon the floor temperature sen sor The built in air sensor is disabled Mechanical Electrical Application 560 2 ...

Страница 8: ...or can be either built in and or external B1 BP PS V1 S1 S2 T1 ZVC1 Legend ZVC1 Thermostat 560 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 S1 Floor Sensor 079 S2 Optional Indoor Sensor 084 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V Mechanical Electrical Application 560 3 ...

Страница 9: ... be either built in and or external B1 BP PS V1 S1 T1 ZVC1 ZVC1 Thermostat 560 C R RH1 W1 AWAY S1 S2 SEN COM Zone Valve Control or Switching Relay C R AWAY W Legend B1 Boiler BP Boiler Pump PS System Pump T1 Thermostat 560 S1 Optional Indoor Sensor 084 V1 Zone Valve ZVC1 Zone Valve Control 304V or 306V Mechanical Electrical Application 560 4 ...

Страница 10: ...ttings are available For a combination of air and floor temperature control leave the internal air sensor on in the setup menu A floor minimum can be used to prevent a fast drop in temperature caused by receding solar exposure This operation is recommended for areas heated by afternoon sun through large windows When the sun sets it can take a long time for the floors to get warm again This may cau...

Страница 11: ...ule applies the new temperature to the current schedule event Go to settings Swipe to view Outdoor temperature Floor temperature Heat To setting Go to schedule After 60 seconds of inactivity the thermostat home screen displays only the time and the temperature Save Cancel Mode Off Heat Temperature Adjustment Hold Until 5 00 PM Save to Schedule 70 Heat To MENU SELECTION AWAY SCHEDULE DISPLAY TIME S...

Страница 12: ...n Wake 6 00 AM 70 Leave 8 00 AM 65 Return 6 00 PM 70 Sleep 10 00 PM 65 Schedule Mon Tue Wed Thu Fri Info Set heating temperature Select skip if you don t want a temperature change Set schedule start time On Skip Wake Schedule Setup Mon Tue Wed Thu Fri 6 00 AM Heat to 70 Operates normally Operates using the Away temperature selected in the Setup menu Use the Away setting to save energy when the bui...

Страница 13: ... 30 to 100 100 BRIGHTNESS INACTIVE Select the brightness when not in use Off 30 to 100 50 BACKGROUND Select the background color Light Blue Night Latte Espresso Blue LANGUAGE Select the language English Español Français English SCREEN CLEAN Locks screen for 10 seconds to allow cleaning N A N A INACTIVE TIME DISPLAY Select if the time is visible when the display is inactive Off or On On INACTIVE OU...

Страница 14: ... time format 12 or 24 hour 12 hour DAYLIGHT SAVING TIME Select the brightness when not in use Off On On The time and date is manually set by highlighting a field and then using the or buttons Choose from the time options listed below TIME DATE 1 30 PM Aug 25 2016 OPTIONS Time ...

Страница 15: ... Select between user and installer access levels User access level restricts access in the Setup Menu User Installer Installer STATUS The current status of warm weather shut down cold weather shut down and each of the relays WWSD W1 N A SOFTWARE VERSION Display the software version J1302 1 0 0 N A LOAD DEFAULTS All settings are returned to factory defaults Yes No No CALIBRATE TOUCHSCREEN Recalibra...

Страница 16: ...oor temperature while in the sleep schedule Applies when there is both a floor and an air sensor Off 40 to 95 F Off 4 5 to 35 0 C Off FLOOR MIN AWAY Select the floor temperature while in away Applies when there is both a floor and an air sensor Off 40 to 95 F Off 4 5 to 35 0 C Off Screen Page 2 FLOOR MAX Select the maximum floor temperature This protects the floor covering from over heating Applie...

Страница 17: ...connected to S2 and Com wiring terminals Off Room Floor Outdoor Off INTERNAL ROOM SENSOR Select if the internal room temperature sensor is on or off Only available when Sensor 1 or 2 is set to read a room or floor sen sor Off On On ROOM OFFSET Select if the internal room temperature sensor is on or off Only available when Sensor 1 or 2 is set to read a room or floor sen sor Off 5 to 5 F 3 0 to 3 0...

Страница 18: ...cording to the sensor installation manual It may be necessary to replace the auxiliary sensor Once the error has been corrected the error message automatically clears SENSOR 2 FAULT Due to an open or short circuit the thermostat is unable to read the sensor wired to S2 and Com The thermostat stops normal operation if sensor 2 is the only active room or floor sensor or if a floor maximum temperatur...

Страница 19: ...s 4 5 8 H x 3 W x 15 16 D 118 x 76 x 24 mm Enclosure White PVC plastic NEMA Type 1 Approvals Meets Class B ICES FCC Part 15 Ambient conditions Indoor use only 32 to 122 F 0 to 50 C RH 90 non condensing Power supply 15 to 30 V ac dc 2 VA standby Class 2 Relays 30V ac dc 2 A Class 2 circuits Sensor NTC thermistor 10 kΩ 77 F 25 C 0 2 C ß 3892 Included None Optional tekmar type 070 072 073 076 077 079...

Страница 20: ...t the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation Purchaser shall indemnify and hold tekmar harmless from and against any and all claims liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to i...

Отзывы: