background image

 

5 of 8 

© 203 Watts Radiant

Placement in Existing 091 Socket 

 -----------------------------------

Current versions of the Snow / Ice Socket 09 use #6-32 screws. Previous versions 

of the 09 used smaller #4-40 screws. When replacing an 090, both sets of screws 

are provided. It is recommended to try the smaller screws first to avoid cross 

threading.

Salt and Brine Contamination

 ---------------------------------------

The performance of the snow / ice sensor water detection can be compromised 

when exposed to de-icing agents such as road salt, magnesium chloride, or calcium 

chloride. These contaminants can permanently damage the sensor. It is recommended 

to locate the sensor away from areas exposed to these deicing agents when at all 

possible. Locations to avoid could include tire track areas or areas close to a curb 

where traveling vehicles may splash contaminated water on to the sensor.

Maintenance

 -------------------------------------------------------

The Snow / Ice Sensor is installed in a harsh environment. Accumulation of dirt, salty 

grime, etc., on its surface will inhibit proper water detection. It should be checked 

on a regular basis and, when necessary, cleaned. Before cleaning, the control 

power should be shut off to prevent the control from entering the snow melt mode. 

Next, use a soft bristle brush and warm soapy water to clean the sensor surface. 

Do not use a steel wire brush as this will damage the sensor. Use a paper towel to 

thoroughly dry the sensor surface. After cleaning, re-power the control.

Slab

Brn

Com

Blk

Yel Blu Red

Snow Melting 

Control 653 or 654

The snow / ice sensor cable has 5 wires: Red, Black, Blue, Yellow, and Brown. The 

wires connect to the respective Red, Black, Blue, Yellow and Brown terminals on the 

Snow Melting Control.

Step 3 - Electrical Connections

The Snow / Ice Sensor 090 must be operated by a Watts Radiant Snow Melting 

Control 653 or 654, or a compatible tekmar Snow Melting Control. Operation of 

the sensor by other control systems may result in electrolysis failures not covered 

by the sensor warranty.

Содержание Snow/Ice Sensor Socket 091

Страница 1: ...sor has 65 ft 20 m of wire This product can be used in applications ranging from residential driveways to commercial building fronts such as emergency access entries This sensor allows the above Snow...

Страница 2: ...eas within a larger slab area As well as reading temperatures the sensor also detects surface water The installer should be careful not to place the sensor where standing water could accumulate on its...

Страница 3: ...150m from the sensor to control Avoid tying the conduit to the rebar within 6 2m of the socket This allows the rebar grid to move without disturbing the position of the socket The top of the snow ice...

Страница 4: ...sensor flange This allows the finished surface of the concrete asphalt etc to be troweled flush with the plug The plug must be installed prior to placing the concrete Also ensure that the mounting pla...

Страница 5: ...ed in a harsh environment Accumulation of dirt salty grime etc on its surface will inhibit proper water detection It should be checked on a regular basis and when necessary cleaned Before cleaning the...

Страница 6: ...elow lists the expected resistance values at various sensor temperatures Measure the resistance between the blue and black wires When the sensor surface is dry the reading should be 2 000 000 Ohms Whe...

Страница 7: ...achined stainless steel screws 4 6 32 3 8 flathead slotted stainless steel screws Snow Ice Sensor Socket 091 Literature ES WR Snow_Socket 091 IOM WR Snow_Ice 090 Packaged weight 1 5 lbs 670 g Socket m...

Страница 8: ...Products d Any freight or delivery costs related to the Product or any related electrical products Watts Radiant assumes no responsibility under this Limited Warranty for any damage to the Product cau...

Отзывы: