PWSRTA Twin Alternating Series Softeners
17
Setting Options Table
Volume
Capacity
Regeneration Time
Option
Day
Override
Result
1
AUTO
NORMAL
oFF
Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve capacity at the
next Regen Set Time.
AUTO
NORMAL
Any number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls below
the reserve capacity or the specified number of days between regenerations is
reached.
Any
number
NORMAL
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when volume
capacity reaches 0.
oFF
NORMAL
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of
days between regenerations is reached.
Any
number
NORMAL
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when volume
capacity reaches 0 or the specified number of days between regenerations is
reached.
AUTO
On 0
oFF
Reserve capacity NOT automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of
regeneration will not be allowed to be set because regeneration will always occur
when volume capacity reaches 0.
Any
number
On 0
oFF
Reserve capacity NOT automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of
regeneration will not be allowed to be set because regeneration will always occur
when volume capacity reaches 0.
AUTO
NORMAL on 0
oFF
Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve capacity at the
next Regen Set Time or regeneration occurs after 10 minutes of no water usage
when volume capacity reaches 0.
AUTO
NORMAL on 0
Any number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls below
the reserve capacity or the specified number of days between regenerations is
reached or regeneration occurs after 10 minutes of no water usage when volume
capacity reaches 0.
Any
number
NORMAL on 0
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of
days between regenerations is reached or regeneration occurs after 10 minutes of
no water usage when volume capacity reaches 0.
Filters should only use shaded options