background image

12                                                                  PWSR Series Softeners

Press the 

Set Clock

 button

Adjust hours using the 

Up

 and 

Down

 arrow buttons

Press the 

Next

 button to advance 

to the minutes .

Adjust minutes with the 

Up

 and 

Down

 arrow buttons .

Press the 

Next

 button to set time

To Exit

Chart 1: Setting Time of Day

The 

Water Hardness

 level of the feed water needs to be known prior to programming system as well as the 

Water Softener Capacity

 of the 

system being installed, to insure proper programming and efficiency of system

NOTICE

Once in the programming settings, simply use the 

UP

 and 

DOWN

 arrow buttons to change values

NOTICE

To enter the Master Programming 

mode, press and hold the 

NEXT

 

and 

DOWN

 arrow buttons simulta-

neously for 3 – 5 seconds

The display will change to 

SET SOFTENING

 with the word 

SOFTENING

 will be blinking . 

This indicates you are now in the Master Programming Mode
System Type – For a 

WATER SOFTENER

, leave this setting alone . If for some reason the 

display reads 

SET FILTER

, press the 

UP

 arrow button and change to 

SET

 

SOFTENER

Press 

NEXT

 Button

Capacity – Enter the 

CAPACITY

 of the water softener that you have ie . 

30K, 45K, 60K or 

90K.

Press 

NEXT

 Button

Salt Setting – Enter the desired pounds of salt per regeneration ie . 6 lbs . per cu .ft . of resin for 

most efficiency, 15 lbs . per cu .ft . for maximum capacity – default setting should be 

9

 pounds 

for a 45K water softener – you must confirm

Press 

NEXT

 Button

A 30K water softener has 1 cu .ft ., 45K has 1 .5 cu .ft ., 60K has 2 cu .ft . and 90K cu .ft . has 3 

cu .ft . Example - 45K water softener would be set to a minimum salt setting of 9 pounds for 

most efficiency (recommended)

Press 

NEXT

 Button

Backwashing Mode - Setting to Normal or Longer . 

NORMAL

 is the standard setting . Longer 

may be needed for well water with heavier sediment issues . Contact Pure Water Technical 

Support at 

1.800.224.1299, then press #2

 for details .

Press 

NEXT

 Button

Gallon Capacity Mode - Set to 

AUTO

 for most efficient setting . Owner’s manual has addi-

tional settings, contact Pure Water Technical Support for Details . Note: You may see a gallon 

capacity on this screen, hit the 

UP

 arrow button several times until you see 

AUTO

 on the 

screen . 

Press 

NEXT

 Button

Brine Tank Refill Mode - This setting should be set to 

POST

Press 

NEXT

 Button

Regenerate Flow Mode - This flow setting should be set to Down Flow – 

dn

 .

Press 

NEXT

 Button

Regeneration Time - This setting should be set to 

NORMAL

Press 

NEXT

 Button

This will complete Master Programming Steps

Chart 2: Master Programming

To enter Installation Display Setting 

Programming mode, press and hold 

the 

NEXT

 and 

UP

 arrow buttons 

simultaneously for 3 - 5 seconds

Hardness Setting - Set the level of hardness in grains per gallon (GPG) present in the raw 

water . Example: 

18

 grains per gallon (GPG) . Adjust grains per gallon with the 

Up

 and 

Down

 

arrow buttons .

Press 

Next

 Button

Day Override . Default should be set to 

14

 Days . Watts Pure Water water softeners regener-

ate based on water usage, but this day override setting will come into play if the softener sits 

idle or has not regenerated and will automatic initiate regeneration on the 14th day . 

Press 

Next

 Button

Regeneration Time . Default setting is 

2:00 AM

 . If time change is needed, press the 

UP

 and 

DOWN

 arrow buttons to adjust the hour time .

Press 

Next

 Button

Press the 

UP

 and 

DOWN

 arrow button to adjust the minutes . 

Press 

Next

 Button

Chart 3: Installer Programming

Next you will need to set up Installer Programming, this 

MUST

 be done in addition to the Master Programming

NOTICE

Programming completed, Valve will return to normal mode and will be in service.
If you have additional questions regarding your water softener programming, please contact

  

Pure Water Technical Support at 1.800.224.1299, then press #2

Содержание PWSR Series

Страница 1: ...document on water supplies that contain Hydrocarbons such as Kerosene Benzene Gasoline etc WARNING Read this Manual BEFORE using this equipment Failure to read and follow all safety and use information can result in death serious personal injury property damage or damage to the equipment Keep this Manual for future reference You are required to consult the local building and plumbing codes prior t...

Страница 2: ...RE SHIP WT LBS TANK SIZE RESIN FT3 GRAVEL LBS TANK SIZE SALT FILL SERVICE GPM DROP PSI BKW GPM PWSR130 30 000 1 9 x 48 1 15 18 x 36 350 9 12 15 25 2 2 110 PWSR145 45 000 1 10 x 54 1 5 20 18 x 36 350 12 16 15 25 2 7 130 PWSR160 60 000 1 12 x 52 2 30 18 x 36 350 15 20 15 25 3 5 190 PWSR190 90 000 1 14 x 65 3 60 18 x 40 400 18 23 15 25 4 2 265 ...

Страница 3: ...ntly stored in the nonvolatile memory The control valve does not need batteries When the control valve is used as a down flow softener two backwashes always occur The softener will start regenerant prefill before regeneration the prefill starts two hours before the regeneration time set During the 2 hour period in which the brine is being made treated softened water is still available For example ...

Страница 4: ...r outlet must be grounded All electrical connections must be connected according to local codes Be certain the outlet is uninterrupted Install grounding strap on metal pipes The power adapter comes with a 15 foot power cord and is designed for use with the control valve The power adapter is for dry location use only The control valve remembers all settings until the battery power is depleted if th...

Страница 5: ...alled ahead of the water softener D Where to Install the Softener Consider the following points when determining where to install the water softener Place the system as close as possible to a sewer drain Do not install the softener where it would block access to the waterheater or access to the main water shutoff water meter or electrical panels Keep outside faucets on hard water to save soft wate...

Страница 6: ... and contamination Install a By Pass Always install a bypass either a 3 way valve system or the standard bypass for the valve you have This will allow you to shut off the water supply to the softener but still have water in the house if the softener is in need of repair WARNING Do not exceed water pressure of 120 psi 8 2 bar Do not exceed 110 F 43 3 C Do not subject unit to freezing conditions Ins...

Страница 7: ... the PC board prior to disconnecting the motor or water meter plugs from the PC board The motor plug connects to the two pin jack on the left hand side of the PC board The power source plug connects to the four pin jack The four pin jack is between the two pin and three pin jacks The water meter plug gray wire connects to the three The PC board can be removed separately from the drive brack et but...

Страница 8: ...ipes for an electrical ground metal only When finished with plumbing a ground wire should be connected to the copper pipes to complete the ground circuit Use two clamps and 4 copper for this Figure 5 When installing sweat copper follow state and federal codes by using a lead free solder and flux Use a joint compound to seal threaded pipe Some homes use the cold water pipes for an electrical ground...

Страница 9: ...to the softener tank connect the brine draw line to valve body Connect to valve body 3 8 Quick Connect fitting Control valves that use a regenerant come equipped with a 3 8 refill flow control assembly Complete the connection by installing the loose end of the tub ing to the brine valve in the salt tank Connect the Drain Line 1 Plumb the drain line to an appropriate drain abiding by all local city...

Страница 10: ...several cold water and hot water faucets and let run until hot water heater is full and cold water faucets have expelled trapped air Turn electrical power back on or re light the hot water heater Now continue with control valve setup Start Up 1 Confirm that the bypass valve is in the bypass position see im ages 9 10 11 below 2 Place the bypass valve in the bypass position or mode see figures 9 11 ...

Страница 11: ...ted in the Quick Programming Guide please see the detailed programming section of this manual NOTICE The electronics in the PWSR control valve are used across a wide variety of control valves and applications including backwashing filters All programming for the electronics has been included in this manual for reference however the valve must be programmed for Twin Alternating Softening Applicatio...

Страница 12: ...ent issues Contact Pure Water Technical Support at 1 800 224 1299 then press 2 for details Press NEXT Button Gallon Capacity Mode Set to AUTO for most efficient setting Owner s manual has addi tional settings contact Pure Water Technical Support for Details Note You may see a gallon capacity on this screen hit the UP arrow button several times until you see AUTO on the screen Press NEXT Button Bri...

Страница 13: ...lays One of the displays is always the current time of day The second display is one of the following days remaining or gallons remaining Days remaining are the number of days left before the system goes through a regeneration cycle Capacity remaining is the number of gallons that will be treated before the system goes through a regeneration cycle The user can scroll between the displays as desire...

Страница 14: ...ration bacteria growth could develop Some water supplies may re quire periodic disinfecting PROGRAMMING NOTE SANITIZING THE SYSTEM 12 SET TIME OF DAY The user can also set the time of day Time of day should only need to be set after extended power outages or when day light savings time begins or ends If an extended power outage occurs the time of day will flash on and off which indi cates the time...

Страница 15: ...ming injector increases the velocity of the water creating a zone of negative pressure that draws in the concentrated liquid regenerant such as sodium chloride brine potassium permanganate sodium hydroxide hydrochloric acid etc The regenerant blends with the stream of water which passes through the media to regenerate the bed The injector provides a consistent regenerant water mixture ratio over t...

Страница 16: ...orts pressure tap ports etc The installation fitting assemblies are sold in pairs and consist of two fittings two nuts two split rings and two o rings The installation fitting assemblies and the bypass valve are sold separately from the control valve Bypass Valve The bypass valve is typically used to isolate the control valve from the plumbing system s water pressure in order to perform control va...

Страница 17: ... Gear Cover 1 KC12V3002 W100SM Drive ASY Not Shown 7300838 W100SM Transformer 110V 12V 1 7300167 7300165 30K 7300135 45K 7300137 60K 7300139 90K 7300141 7300224 Drawings and Part Numbers Brine Tank and Softener Tank Front Cover and Drive Assembly DRAWING NO ORDER NO DESCRIPTION QTY 1 7300839 W100SM Front Cover ASY 1 2 7300833 W100SM Motor 1 3 KC12F3106 01 W100SM Drive Bracket 1 Spring Clip 4 73008...

Страница 18: ...hat only backwashes injector plugs are located in both holes INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawings and Part Numbers Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston and Spacer Stack Assembly Injector Cap Injector Screen Injector Plug and O ring DRAWING NO ORDER NO DESCRIPTION QTY 1 7300826 W100SM Spacer Stack Assembly 1 2 KC12V3004 Drive Cap ASY 1 3 KC12V...

Страница 19: ... Polytube insert 5 8 Option 3 KC12V3192 W100SM Nut 3 4 Drain Elbow Option 4 KC12V3158 01 W100SM Drain Elbow 3 4 Male ASY 1 5 KC12V3163 O ring 019 1 6 KC12V3159 01 W100SM DLFC Retainer ASY 1 7 KC12V3162 022 W100SM DLFC 2 2 gpm for 3 4 KC12V3162 027 W100SM DLFC 2 7 gpm for ORDER NO DESCRIPTION V4144 01 3 8 Quick Connect Fitting Brine Line Connection Drawings and Part Numbers Drain Line 3 4 DRAWING N...

Страница 20: ... Split Ring 2 3 KC12V3105 O ring 215 2 4 KC12V3189 W100SM Fitting 3 4 1 PVC Solvent 90 2 Drawing No Order No Description Qty 1 KC12V3151 W100SM Nut 1 Quick Connect 2 2 KC12V3150 W100SM Split Ring 2 3 KC12V3105 O ring 215 2 4 KC12V3188 W100SM Fitting 1 Brass Sweat 2 Drawing No Order No Description Qty 1 KC12V3151 W100SM Nut 1 Quick Connect 2 2 KC12V3150 W100SM Split Ring 2 3 KC12V3105 O ring 215 2 ...

Страница 21: ...rder No 7300839 Although no tools are necessary to assemble or disassemble the valve the PWSR Wrench shown in various positions on the valve may be purchased to aid in assemble or disas sembly PWSR Series Softeners 21 Bypass Valve Assembly Drawings and Part Numbers ...

Страница 22: ...ce flow diagram rinse flow diagram backwash flow diagram fill flow diagram downflow brine 22 PWSR Series Softeners Drawings and Part Numbers Flow Diagram Service Flow Diagram Rinse Flow Diagram Fill Flow Diagram Backwash Flow Diagram Downflow Brine ...

Страница 23: ...peated flushing of the hot water tank is required F Leak at distributor tube F Make sure distributor tube is not cracked Check O Ring and tube pilot G Internal valve leaking G Replace seals and spacers and or piston 4 Unit used too much salt A Improper salt setting A Check salt usage and sat setting B Excessive water in brine tank B See Problem No 8 5 Loss of water pressure A Iron buildup in line ...

Страница 24: ...20 P S I E Internal control leak E Change seals spacers and piston assembly 10 Control cycles continuously A Broken or shorted switch A Determine if switch or timer is faulty and replace it or replace complete power head 11 Drain flows continuously A Piston is not positioned correctly when in service A Check timer program and positioning of control Replace power head assembly if not positioning pr...

Страница 25: ...up procedure regeneration time option 5 ERROR followed by code number Error Code 1001 Unable to recognize start of regeneration Error Code 1002 Unexpected stall Error Code 1003 Motor ran to long timed out trying to reach next cycle position Error Code 1004 Motor ran to long timed out trying to reach home position If other Error Codes display contact the factory a Control valve has just been servic...

Страница 26: ...se working outlet c Broken drive gear or drive cap assembly c Replace drive gear or drive cap assembly d Defective PC board d Replace PC board 8 Control valve does not regenerate automatically but does when REGEN button is depressed a Bypass valve in bypass position a Put control valve in service position b Meter connection disconnected b Connect meter to PC board c Restricted stalled meter turbin...

Страница 27: ...NOTES ...

Страница 28: ...ANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT SHALL WATTS BE LIABLE IN CONTRACT TORT STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY FOR INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR PROPERTY DAMAGE REGARDLESS OF WHETHER IT WAS INFORMED ABOUT ...

Отзывы: