ProbleM

Cause

solution

1. Low/slow production

Excessive air pressure in tank

 Relieve pressure at schrader valve on tank (set to 7psi with 

the tank empty)

Pump not operating

 Wiring connection broken (plug 110 AC wall, plug back in at 

wall and/or reconnect the 24 VAC wire harness connectors)

Replace pump if needed

Fouled membrane

Replace membrane

Plugged pre-filters

Replace filters

Crimped tubing

 Check tubes to make sure they are not kinked

Angle stop or water line valve not fully opened

Ensure valves are opened by turning valve handle counter-

clockwise until it stops

2. Milky colored water

Air in the system

Air in the system is a normal occurrence with initial start 

up of the RO system. This milky look will disappear during 

normal use within 1-2 weeks. If condition reoccurs after filter 

changes, drain tank 1 to 2 times.

3. Faucet Dripping

Needs adjustment

see page 12

4. Pump short cycles

Ball valve on tank closed

Open the ball valve on the top of the tank

Blue tube blocked between the tank and RO system Faulty 

pressure switch

Remove kinked/damaged section and replace if necessary 

Call for technical support

5. Bowl leaks at the top after changing the filters

Damaged/Dry O-ring

Lubricate with water soluble lubricant or replace O-ring as 

necessary (Do not use Vaseline® or other petroleum based 

lubricants)

6. Pump constantly running

Electrical fault Faucet left on

Call for technical support. Close faucet and let tank fill for 2 

to 3 hours.

Plugged pre-filters

Replace filters

 Troubleshooting

Содержание PWRO4ZRO Pure Water

Страница 1: ...th Maintenance 8 Annual Maintenance 8 Membrane Replacement 9 Procedure for Extended Non Use More than 2 months 9 Troubleshooting 10 Parts List 11 Arsenic Facts 12 Service Record 13 Limited Warranty 16...

Страница 2: ...Carbon filter recommended change 6 months The second stage contains a five micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly redu...

Страница 3: ...tem was tested in a laboratory setting utilizing a hot water heater of 40 gallons set at 120 F Performance may vary if your heater is smaller than 40 gallons or set above 120 F contact the manufacture...

Страница 4: ...dges be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless st...

Страница 5: ...ures the faucet base snug onto the sink top Step C Once the faucet base is securely fastened to the sink top insert the faucet spout into the faucet base until it is fully seated Turn the handle up aw...

Страница 6: ...gerator ice maker may be tee d into this blue tube and should be spliced in between the final filter and the RO faucet STEP 7 Check Air Pressure in the Tank Note Check air pressure when tank is empty...

Страница 7: ...rness connector labeled Transformer Step C Plug the transformer into the electrical outlet under the sink Step D Open the RO faucet and leave it open until water begins to trickle out it will come out...

Страница 8: ...brane 1 Carbon Block Filters 1 Final Inline Filter Note Sanitizing of unit is recommended Step A Perform steps A through E in the Six Month System Main tenance Note If not sanitizing the system skip t...

Страница 9: ...he Adapt A Valve clockwise until it stops Step B Open the RO Faucet and allow water to drain from the tank until it is completely empty Removing the Membrane Step A Use a 5 8 wrench to remove the Gree...

Страница 10: ...nce with initial start up of the RO system This milky look will disappear during normal use within 1 2 weeks If condition reoccurs after filter changes drain tank 1 to 2 times 3 Faucet Dripping Needs...

Страница 11: ...4 7300075 DOUBLE CHECK VALVE 5 7300015 PRESSURE SWITCH 6 7300001 BOOSTER PUMP 1 4 QC 7 7300000 TRANSFORMER 8 7300076 SELENOID VALVE 9 7100203 TOP MOUNT FAUCET CHROME 10 7100446 CARBON BLOCK FILTER 11...

Страница 12: ...lso called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water util...

Страница 13: ...Date of Purchase Date of Install Installed by Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 3rd stage Carbon 6 months Final Filter Carbon 1 year TFM Membrane 2 5 years Notes Service Reco...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...arranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERM...

Отзывы: