manualshive.com logo in svg
background image

5

Adapt-A-Valve™ Installation

Verify contents prior to installation:

( 1 ) - Plastic Adapt-a-Valve™ & Black Collet 

( 1 ) - Brass Adapter no washer 

( 1 ) - Brass Adapter with black washer  

( 1 ) - White rubber washer

Water supply line to the system must be from the cold water 

supply line only. Hot water will severely damage your system.
WARNING:  Do not use Teflon tape with the Adapt-A-Valve™. 

For 

3

8

" Configuration  

For 

1

2

" Configuration  

Step A -

  Turn off the cold water supply to the faucet by turning the 

angle stop valve completely off . 

Step B -

  Open cold water sink faucet to relieve pressure . 

Step C -

  Choosing the configuration that fits your plumbing, at-

tach the Adapt-A-Valve™ as illustrated in the four photos 

above .

STEP 3

Hot

Supply

Cold

Supply

Hot

Supply

Cold

Supply

(With Brass Fittings) 

* Insert White Washer

(Without Brass Fittings) 

1

2

" Configuration

Drain Saddle Installation -  

Fits standard 1¼" – 1½" drain pipes

Follow all local plumbing codes for your installation.

Caution:  If you have a garbage disposal, do not install the drain 

saddle near it. Installation of the drain saddle must be either 

above the garbage disposal, or if a second sink drain is avail-

able, install it above the cross bar on the second drain. Installa-

tion of the drain saddle near a garbage disposal may cause the 

drain line to plug.
Step A –

  Locate the drain saddle kit in the parts bag .

Gather the pieces of the drain saddle
( 1 ) - Black compression nut 

( 1 ) - Semicircle bracket with opening 

( 2 ) - Screws 

( 1 ) - Foam gasket 

( 2 ) - Nuts for screws 

( 1 ) - Semicircle bracket

Step B –  

The small square black foam gasket with a circle cut out 

of the middle must be applied to the inside of the drain 

saddle . Remove sticky tape backing and stick to the drain 

saddle as shown . 

Step C – 

 The drain saddle must be installed 

at least 1 ½" above the nut of the 

P-Trap elbow or cross bar from the 

garbage disposal to insure proper 

drainage . Using the 1/4" drill bit, 

drill into the drain pipe at best avail-

able location as specified above, 

for drain saddle installation . Take 

extreme caution to only drill through 

one side of the drain pipe .

Step D – 

 Assemble the drain saddle around the drain pipe and align 

drain saddle fitting opening with the hole drilled in the 

previous step - you may use a small screwdriver to feed 

through the drain saddle into the drain pipe to aid with the 

alignment . Using a Phillips screw driver tighten the drain 

saddle bolts evenly and securely on both sides .

Caution: Do not over tighten the screws. It may crack the drain 

saddle.

Drain Saddle Tube Connection 

The black 3/8" drain tube must be as SHORT and STRAIGHT as 

possible to the drain saddle, making a downward slope from faucet 

to drain saddle to allow for proper drainage . This is a gravity fed line 

and if there is any bend or dip in the tube, the rinse water will not 

flow into the drain properly . Water may back up and come out the air 

gap hole in the back of the faucet . 

Step A –

  Measure the 3/8" drain tube from faucet to the drain saddle 

on the drain pipe and make a straight cut to the correct 

length .

Step B –  

Slip drain tube through black 

compression nut . Insert drain 

tube into the opening in the 

drain saddle and hand tighten 

the black nut, and add 1/4 turn 

with a wrench .

STEP 4

1.5"

P-Trap 

Elbow

Содержание PURE WATER PWSYS-RO-STD4-50

Страница 1: ...be from Faucet to the Drain Saddle 6 Green Tube Connection 6 Reverse Osmosis Module Mounting 6 Red 1 4 Tube Connection from faucet 6 Check Air Pressure in the Tank 6 Tank Tee Installation 6 Blue Tube...

Страница 2: ...d other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended change 2 5 years Stage 3 is the heart of the reverse osmosis system the RO membrane This semi permeable...

Страница 3: ...s supplies speciality filters that can be used if copper tubing follows the Reverse Osmosis unit Be sure to follow any state or local regulations during installation Drill a Hole for the Faucet in a P...

Страница 4: ...ite plastic insert Item 13 into the end of blue tubing with the delrin sleeve Insert the blue tube Item 12 into the faucet stem and secure with nut Item 11 Note DO NOT overtighten nut Standard Faucet...

Страница 5: ...tep B The small square black foam gasket with a circle cut out of the middle must be applied to the inside of the drain saddle Remove sticky tape backing and stick to the drain saddle as shown Step C...

Страница 6: ...any RO system tubes at this time STEP 8 Red 1 4 Tube Connection from faucet Step A Using the white plastic union found in the parts bag deter mine where the 1 4 red tubing from the faucet and the 1 4...

Страница 7: ...stem contains replaceable treatment components that are critical for effective containment reduction Periodic inspection and following proper system maintenance is critical for continued performance S...

Страница 8: ...Line Filter Note Sanitizing of unit is recommended Step A Perform steps A through E in the Six Month System Main tenance Note If not sanitizing the system skip to step H Step B Remove the RO membrane...

Страница 9: ...he Adapt A Valve clockwise until it stops Step B Open the RO Faucet and allow water to drain from the tank until it is completely empty Removing the Membrane Step A Use a 5 8 wrench to remove the Gree...

Страница 10: ...should be 5 7psi See Page 9 4 Noise Water from faucet vent hole or noise from in drain line drain Crimp or restriction Check tubing and straighten or repair as necessary Straighten all drain lines Cl...

Страница 11: ...IRGAP FAUCET CHROME 16 7300030 DRAIN SADDLE 3 8 17 7300022 FLOW RESTRICTOR NOT SHOWN 18 7100331 SEDIMENT FILTER 19 7100446 CARBON BLOCK FILTER 20 7300081 FILTER HOUSING LID 1 4 PORTS 21 7300044 FILTER...

Страница 12: ...also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water ut...

Страница 13: ...Date of Purchase Date of Install Installed by Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 3rd stage Carbon 6 months Final Filter Carbon 1 year TFM Membrane 2 5 years Notes Service Reco...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...ated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLE...

Отзывы: