Check frequently over the next 24 hours to ensure no leaks 

are present

System Start Up

Annual Maintenance 

Replacement 

fi

lter: High Capacity Quick Turn 

Carbon Filter (12 Months- PN# 88005232) 

H2O-F45

To buy replacement part(s) please visit the retail store or their 

website or contact Watts retail customer service at

  

(888) 321-0500

Step 1

 -  Turn on water supply at cold water angle stop. 

Turn cold water faucet handle to the open position 

to start the 

fl

ow of water through the unit. Run 5 

gallons of water through the unit in order to 

fl

ush 

out the normal black carbon 

fi

nes (it will “sputter” 

until the air is purged out) from the unit. A container 

with a known volume can be 

fi

lled to determine how 

much water has 

fl

ushed through the system. Initially, 

the water may appear cloudy which is due to tiny air 

bubbles and it will clear up shortly. Close the faucet 

when 

fi

nished.

Step 2

 -  Check for leaks. If you have any leaks, shut off the 

water supply to your system, tighten any 

fi

ttings then 

turn the supply back on.

Step 1

 -  Turn off incoming water supply to the 

fi

ltration unit.

Step 2

 -  Open the cold water faucet handle to relieve the 

water pressure.

Step 3

 -  Remove the 

fi

lter from the head by turning to the left, 

then pulling downwards. Discard the old 

fi

lter.

Step 4

 -  Remove plastic wrapping and cap from new 

fi

lter.

Step 5

 -  To install new 

fi

lter cartridge, with the 

fi

lter label facing 

approximately 45 degrees to the left, push the 

fi

lter 

into the 

fi

lter head and twist it to the right until the 

fi

lter locks in and the label on 

fi

lter is facing the front.

Step 6

 -  Follow start-up procedure.

Step 4

Step 5-2

Step 3

Step 5-1

NOTICE

Product Registration

To Register your product, please visit www.watts.com/pureh2o 

and select “Register Now”. Watts is concerned for the safety of 

your personal information. Watts collects personal information 

when you register with Watts. This information is stored in our 

data base and we do not rent, sell, or share personal information 

with other people or nonaf

fi

liated companies. We will send you 

certain types of communications such as direct mail, email, or 

by telephone relating to our products or products that you have 

purchased only with your prior permission. We limit access to 

your personal information to those employees who will directly 

provide you with services or products in order to do their jobs.

See our privacy policy at - http://www.watts.com/privacy.asp

See Terms of Use at - http://www.watts.com/terms.asp

Tubing not shown in above pictures. Do not remove the tubing 

while changing the filter

NOTICE

Содержание Pure H2O Series

Страница 1: ...n Filter Replacement Design System Tested and certified by WQA against NSF ANSI Standards 42 and 53 for the reduction of the claims specified on the performance data sheet and NSF ANSI Standard 372 for Lead Free Compliance WARNING Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Keep...

Страница 2: ...le of Contents Overview 2 System Maintenance 2 Operational Parameters 2 Contents of Under Counter System 3 Recommended Tools For Installation 3 Using Quick Connect Fittings 3 System Diagram 3 Tubing Connections and Mounting 4 Start up Instructions 5 Product Registration 5 Changing the Filter Cartridges 5 Performance Data Sheet 6 Service Record 7 Limited Warranty 8 WARNING Do not use with water tha...

Страница 3: ...ewdriver Using Quick Connect Fittings Cutting Make certain to push the tubing completely into the connector until it comes into contact with the internal tubing stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a permanent leak proof seal Pull on the tube to check that it is secure The system must be tested prior to leaving the site ...

Страница 4: ...nd replacement Mark the location for the mounting screws on the cabinet wall under the sink In the parts bag locate the two self tapping screws Using an electric drill with a Phillips bit screw them into the cabinet at the marked location Hang the system on the screws using the mounting holes in the bracket Step 1 The tubing is now connected on one end to the faucet supply and the other end to the...

Страница 5: ...ter from the head by turning to the left then pulling downwards Discard the old filter Step 4 Remove plastic wrapping and cap from new filter Step 5 To install new filter cartridge with the filter label facing approximately 45 degrees to the left push the filter into the filter head and twist it to the right until the filter locks in and the label on filter is facing the front Step 6 Follow start ...

Страница 6: ...e with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system While testing was performed under standard laboratory conditions actual performance may vary Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts 2 Operating Temperature Maximum 100o F 38o C Minimum 40o F 4 4o C 3 Operatin...

Страница 7: ...e Record Date of Purchase _______________ Model Number _______________ Serial Number _______________ Date of Install _________________ Installed by __________________ High Capacity Quick Turn Carbon filter 12 Months ...

Страница 8: ...ioned equipment Parts used in repairing or replacing the system will be warranted for 90 days from the date the system is returned to you or for the remainder of the system s original warranty period whichever is longer This warranty is not assignable or transferable Limitations and Exclusions THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS WITH RESPECT TO ...