manualshive.com logo in svg
background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 Comfort 

Mode:

  

Use this mode to set your installation indefinitely in Comfort mode. 

The room temperature and the humidity level are displayed all the time. If you press 

 you can see the setting 

temperature and actual time. 
You can adjust the comfort temperature for this zone with 

 and 

 keys. (Default setting 21°C) 

Every others zones will follow there thermostat setting temperature. 

 

 

 Automatic 

Mode:

 

In this mode your installation follows the program assigned for each zone. Press 

 to see the program followed of 

the current zone,  

The room temperature and the humidity level are displayed all the time. If you press 

 you can see the actual 

time and the graphic programme for the selected zone. To see others zones use 

 and 

 keys. 

 

 

 Reduce 

Mode:

 

Use this mode to put your installation indefinitely in reduce mode. 

The room temperature and the humidity level are displayed all the time. If you press 

 you can see the delta 

temperature (difference between the comfort temperature and reduced temperature). 
You can adjust the delta temperature (dt) with 

 and 

 keys. (Default setting 4°C) 

Every others zones will follow there thermostat setting temperature minus or plus (depending of your choice on the 
receiver) the dt  
Example for one zone =>comfort temp. 22°C –/+ dt (4°C) = the reduced temperature for this zone will be 18°C 

 

 

  

Anti-Freeze Mode:

 

Use this mode to protect your installation against freeze. 

The room temperature and the humidity level are displayed all the time. If you press 

 you can see the setting 

temperature and the time. 
You can adjust the anti freeze temperature with 

 and 

 keys. (Default setting 6°C) 

Every others zones will follow this setting temperature. 

 

  

Holiday Mode:

 

Use this mode for an absence period. (For your holiday per example) 

To access to this mode place your thermostat in Anti-Freeze mode 

 

, push the  

 key, the 

is displayed  

Now you can adjust with 

 and 

 the period duration. (In hours “

H

” if below 24h then in days “

d

”). 

When the period is finish the thermostat will come back automatically in 

 mode.  

If you want to interrupt this period, adjust the duration to “

no

”. 

The temperature applied for this duration is the temperature value adjusted in anti-freeze mode 

 

  

Operating Mode 

(only available if 

H.C: Menu

 parameter is activated):

 

 Use 

 to select « 

Mod HEAT

 » 

for heating application only (or in winter season with manual reversible 
Heat and Cold system). 

 Use 

 to select « 

Mod COOL

 » 

for cooling application only (or in summer season with manual 
reversible Heat and Cold system) 

 Use  to select « 

Mod Auto

 » 

for automatic reversible heat and cold system. 

 

 

 

 

Set Clock Menu: 

Use this mode to adjust the clock and day. 

Press 

, to adjust the minute with 

 and 

 keys. 

Press 

, to adjust the hour with 

 and 

 keys. 

Press 

, to adjust the day with 

 and 

 keys. 

 

 

 

 

Program Menu:

 

Use this mode to assign or edit a program for each zones of your installation. 
(See the PROGRAM EDITION menu for more explanation) 

By pressing  

 key the zone number starts to blink, 

 
  

 

Use 

 

/

 to see the 

With 

/

 you can Select  

 

 

 

other days of the program 

The zone or the User program. 

 

 

 

 

(See 

User 

program 

edition) 

   Program 

number 

      Shows 

the 

daily 

program 

 
 

If you select a zone number “

01

” to “

12

” and press 

, you can then select a weekly program to be followed for 

this zone. 

 
The program numbers start to blink: 
Use

 

/

 to select the program. 

 

 

 

If you select a built in program 

“P1”

 to

 “P9”

 or a user program 

“U1”

 to

 “U12”

, and press 

, then this program 

will be followed in 

 mode. 

 
Built-in programs description 
 
P1:

  

Morning, Evening & Week-end 

 

P6:

  

Morning, Afternoon & Week-end

 

P2:

  

Morning, Midday, Evening & Week-end   

P7:

  

7h - 19h (Office)

 

P3:

  

Day 

Week-end 

   

P8:

  

8h – 19h , Saturday (Shop)

 

P4:

  

Evening & Week-end 

 

 

P9:

  

Week-end (Secondary House)

 

P5:

  

Morning, Evening (bathroom) 

 
User programs edition: 
 
 
 
 
 
1/ Program editing: 

First of all, select a user program (

U1

 to 

U12

) with 

 and 

 keys. Press 

, the first cursor of the program 

graphic starts to blink. Then, you can choose the state of temperature (

 or   with 

+/-

 keys) 

at the current hour. 

 

Use 

 and 

 keys to slide the blinking cursor position in the day and modify or correct easily the program. 

When the displayed day is correct, press 

 to jump to the following day. 

When you press 

 on day 7 you return to the top menu .Now your user program will be followed if you select 

this user program for a zone and put your thermostat in 

 operating mode. 

 

2/ Program assigning: 

You can also assign a different program at each zone, to do this, select a zone (

01

 to 

12

) with 

 and 

 keys,  

the zone number blinks, then press 

, now the program number blinks, you can select with 

 and 

 the 

program which will be followed by the selected zone. 

 

PROGRAM EDITION 

In order to configure the RF-thermostat with the receiver, 

the receiver must be in the “

RF init

” mode (see the receiver leaflet for more explanation)  

- Press 

the   key during 5sec to enter the parameters menu.  

 

 

 

       

When “

CrF init

” and the graphic  

  

   

appears the thermostat send the radio 

configuration at the receiver. 

Once the receiver is configured press 

 key to come back in the main menu  

 

PAY ATTENTION!!!

 The thermostat has to be placed near to the receiver for correct configuration. 

RADIO CONFIGURATION (Link emitter with the receiver) 

day 

Hour at the cursor 
position 

The 

  key sets   temperature at the current blinking program hour 

The 

 key sets 

temperature at the current blinking program hour

Отзывы: