background image

Page 7 of 7

Technical Support

  •  (800) 433-5654  •  Mon-Fri, 8 am - 5 pm EST

Limited Warranty

Lync warrants its AquaSolve tank system as follows: 

•  AquaSolve tank system is warranted to be free of defects in materi-

als and workmanship for 5 years from the date of original shipment.

•  The AquaSolve media is warranted for performance for a period of 

2 years from the date of the original installation when installed and 
oper-ated in accordance with the instructions in the corresponding 
Installation and Operation Manual.  

Conditions

•  AquaSolve system must be installed in applications with municipally 

supplied water adhering to EPA guidelines with the exception of 
oil and grease, copper, phosphate, silca and chlorine. See copper 
warnings on page 2 and condition number 5 below.

Parts List

Item

Qty.

Lync Part #

Description

1a

1

144064

SS tank head only

1b

1

149692

Upper basket assembly

2

2

144065

Flex hose 2” x 12”

3

1

144066

Distributor tube and bottom  
distributor assembly

4a

1

148783

14” X 65” tank 4” top

4b

1

148784

16” X 65” tank 4” top

1.  Any component failure must not result from abuse, fire, freezing or 

other acts of nature, violence, or improper installation.

2.  Equipment must be installed and operated in compliance with the 

local plumbing codes and on an approved water supply.

3.  Equipment is limited to use at water pressures and temperatures that 

do not exceed our published specifications.

4.  Water supply must not exceed 2.0 PPM chlorine. For water supply 

exceeding 2.0 PPM chlorine, pretreatment is required. (Please con-
tact your water treatment specialist.)

5.  Information, including model number, serial number, and date of 

installation, must be provided for any claims pertaining to equipment 
in warranty.

6.  Defective parts are subject to inspection by either Lync or any 

authorized representative before final commitment of warranty 
adjustment is made.

7.  Lync reserves the right to make changes or substitutions in parts or 

equipment with material of equal quality or value and of then current 
production.

Limitations

 

Our obligation under this warranty with respect to the tank or valve is 
limited to furnishing a replacement for, or at our option, repairing any 
part or parts to our satisfaction that prove defective within the warranty 
period stated above. Such replacement parts will be delivered to the 
owner F.O.B. nearest factory, at no cost, excluding freight and local 
labor charges, if any. Our obligation under this warranty with respect 
to the Lync Anti-scale media will be limited to furnishing a replacement 
for the media within two years from date of original installation. Such 
replacement media will be delivered to the owner F.O.B. nearest factory, 
at no cost, excluding freight and local labor charges, if any. Damage 
to the media due to chlorine, other oxidizers or fouling caused by local 
water conditions or any other operation outside of the limits shown under 
Specifications, is not covered by this warranty. 

The warranty set forth herein is given expressly and is the only warranty 
given by Lync company with respect to the product. Lync company 
makes no other warranties, express or implied. Lync company hereby 
specifically disclaims all other warranties, express or implied, including 
but not limited to the implied warranties of merchantablity and fitness for 
a particular purpose. 

The remedy described under this warranty shall constitute the sole and 
exclusive remedy for breach of warranty, and Lync company shall not 
be responsible for any incidental, special or consequential damages, 
including without limitation, freight, handling, lost profits or the cost of 
repairing or replacing other property which is damaged if this product 
does not work properly, other costs resulting from labor charges, delays, 
vandalism, negligence, fouling caused by foreign material, damage from 
adverse water conditions, chemical, or any other circumstances over 
which Lync company has no control. This warranty shall be invalidated 
by any abuse, misuse, misap-plication or improper installation of the 
product.

Some states do not allow limitations on how long an implied warranty 
lasts, and some states do not allow the exclusion or limitation of inciden-
tal or consequential damages. Therefore the above limitations may not 
apply to you. This warranty gives you specific legal rights, and you may 
have other rights that vary from state to state. You should consult appli-
cable state laws to determine your rights. So far as is consistent with 
applicable state law, any implied warranties that may not be disclaimed, 
including the implied warrantied of merchanability and fitness for a par-
ticular purpose, are limited in duration to the applicable warranty periods 
stated above.

Operation & Maintenance Manual

Lync AquaSolve

L-OMM-010_A

Alternative Method for Replacing Media

Follow steps 1 – 5 then,

•  Remove center distributor tube and lower basket 

and siphon all water from tank

•  Lay tank down on its side and tip upside down while 

using hose to flush media out

•  When all the old media is removed, stand tank back  

up and install in original position. Fill the tank so  
that it is about half full with water.

Then continue with steps 12 – 18.

Содержание Lync AquaSolve LM8414TM-COM

Страница 1: ...00 Fort Worth TX 76134 817 335 9531 Technical Support 800 433 5654 ext 3 Mon Fri 8 am 5 pm CST Engineered Solutions L OMM 010_A Important Read this Manual BEFORE using this equipment Failure to read and follow all safety and use information can result in death serious personal injury property damage or damage to the equipment Keep this Manual for future reference 2021 Lync ...

Страница 2: ...rystals making AquaSolve an effec tive alternative technology to a water softener for the prevention of scale due to water hardness Virtually maintenance free no control valve Uses environmentally friendly technology by using no salt or other chemicals to constantly add no electricity and no wastewater Improves efficiency of all water using appliances both hot and cold Simple sizing and installati...

Страница 3: ...olve in conjunction with other forms of water treatment 1 AquaSolve must be the last stage in the treatment chain Do not install any filters after Lync AquaSolve or before any devic es for which scale prevention is required POU filters e g car bon RO or Ultraviolet UV are exempt from this requirement 2 Do not apply any other antiscalants before or after AquaSolve 3 The addition of soaps chemicals ...

Страница 4: ...g AquaSolve technology prevent hard water scale formation inside the plumbing system at influent hardness levels of 30 grains per gallon of calcium carbonate and less Due to vari ances in water chemistry certain aesthetic conditions external of the plumbing system may not be attained AquaSolve is designed for the treatment of potable water that meets the requirements of the current USEPA Safe Drin...

Страница 5: ...applicable local codes Include sample drain ports with hose bibb connec tions on the inlet and outlet piping to facilitate startup and service Support the Piping 2 inch Flex Connectors must be installed horizontally not vertically in the water pipe line The full weight of the piping and valves must be supported by uni strut pipe hangers or other means The tank connections cannot support the weight...

Страница 6: ...edia You need to take it out in small bites If you Your AquaSolve media should be replaced every 3 years Dispose of old media and or container in accordance with local regional national and or international regulations NOTICE let the whole pipe hose fill with media it will plug up You need to let slugs of water flush out the pipe as you go 11 When all the old media is removed turn off the garden h...

Страница 7: ... media will be limited to furnishing a replacement for the media within two years from date of original installation Such replacement media will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Damage to the media due to chlorine other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown ...