System Specifications

Maximum Pressure: 125psi/8 .6 bar
Maximum Temperature: 100°F/38°C
Inlet/Outlet Connections: ¾" FNPT with ½" FNPT on remote ice filter 

housings .  
Maximum Flow Rate: 4 GPM

Filter Cartridge Life Span  

Filter cartridges should be changed at 20,000 gallons, 15psi overall 

system pressure drop at normal flow rate, or 6 months, which ever 

comes first .   

Please note:

 Cartridge capacities are estimates and may be less 

depending on incoming water quality . Cartridges should be changed 

at least every 6 months .    

Notice to Installer

•  Do not discard this manual after installation . This manual contains 

important operation, maintenance and precautionary information . 

Please present this manual to the user/owner/operator after instal-

lation .

•  It is strongly suggested that you read this manual before installing 

system to ensure the best possible installation .

•  Installation must comply with all local and state plumbing codes 

and regulations . 

•  Connect the system to cold water supply only . Water Temperature 

cannot exceed 100°F/37°C .

•  System must be installed in a vertical, upright and level position . 
•  Do not use with water that is microbiologically unsafe or of un-

known water quality .

•  Notice to user/owner/operator: Please retain this manual for a 

future reference for parts, maintenance, or troubleshooting .

•  It is recommended that all personnel responsible for operation and 

maintenance of this product read the precautions, maintenance, 

and operation sections of this manual .   

Installation Precautions

•  Do not install system on line pressure above 125psi .
•  Do not install the system on a hot water line . Failure to limit the wa-

ter temperature to 100°F can result in housing failure and property 

damage .

•  Do not connect the system backwards with the feed water line 

connected to the outlet . 

•  Do not use liquid pipe thread compounds for threaded connec-

tions . Use Teflon

®

 tape only .

•  Do not solder plumbing connections that are attached to the hous-

ings or inlet/outlet fittings . System damage may occur due to high 

temperature .

•  Do not allow the system to freeze . Turn off water supply and drain 

the system if temperature falls below 32°F . 

•  Do not install system in direct sunlight or where the system will be 

exposed to harsh chemicals or may be subjected to being hit by 

moving equipment, carts, mops, or any other item that may cause 

damage . 

•  Allow 3" minimum clearance under the housings for filter replace-

ment . 

•  If water hammer is evident, install water hammer arrestors before 

the system . 

•  Do not over tighten fitting connections . 
•  Always back up valves and fittings with a wrench when installing 

fittings to avoid over tightening or loosening existing fittings . 

•  Do not install the unit behind equipment where it may be difficult to 

access the system for future filter replacements . 

Position the system in a suitable location . The direction of flow 

through the system is left to right . Keep this in mind when determin-

ing installation locations . Do not mount the system near any source 

of heat . Also do not mount this system over anything that may be 

adversely affected by water .  

Replacement Filters

Model

Frequency

description

PWFIL-SED-STD-10-20M-DEP

10" Sediment filter

PWFIL-CB-STD-20-5M-8K

20" Carbon Block filter (2 required)

PWFIL-PHOS-STD-10-24

10" Polyphosphate filter (2 required)

note:

 Water conditions may require more frequent cartridge replacement