2
System Specifications
Maximum Pressure:
Slimline Systems - 125 psi (8 .6 bar), Cold Bev Max Models S2, S2L,
S3L
Big Blue Systems - 90 psi (6 .2 bar), Cold Bev Max Models S1BBL,
S2BBL, and S3BBL
Maximum Temperature: 100°F (38°C)
Inlet/Outlet Connections: 3/8" (10mm) NPT for Slimline Models,
3/4" (20mm) NPT for Big Blue Models .
pH 6 .5 to 8 .5
Chlorine < 2ppm
Iron (maximum) 0 .3 mg/l
Manganese (maximum) 0 .05 mg/l
Oil & H2S- None allowed
For all other feed water quality requirements abide by the current
USEPA Safe Drinking Water Act standards .
Maximum Flow Rate:
System Flow Rate
System Model
Flow Rate
Cold Bev Max-S2
1 GPM
Cold Bev Max-S2L
2 GPM
Cold Bev Max-S3L
2 GPM
Cold Bev Max-S1BBL
6 GPM
Cold Bev Max-S2BBL
6 GPM
Cold Bev Max-S3BBL
6 GPM
Cold Bev Max line is available in different configurations depending
upon filtration and flow requirements .
Slimline models use 2
¾"
(70mm) in diameter filters and are available
in either 10" (250mm) or 20" (500mm) length options . The slimline
models are equipped with 3/8" (10mm) NPT fittings .
Big Blue models use 4½" diameter filters and are available in either
10" (250mm) or 20" (500mm) length options . The Big Blue models
are equipped with 3/4" (20mm) NPT fittings .
Notice to Installer
• Do not discard this manual after installation. This manual contains
important operation, maintenance and precautionary information .
Please present this manual to the user/owner/operator after instal-
lation .
• It is strongly suggested that you read this manual before installing
system to ensure the best possible installation .
• Installation must comply with all local and state plumbing codes
and regulations .
• Connect the system to cold water supply only. Water Temperature
cannot exceed 100°F (37°C) .
• System must be installed in a vertical, upright and level position.
• Do not use with water that is microbiologically unsafe or of un-
known water quality .
• Notice to user/owner/operator: Please retain this manual for future
reference for parts, maintenance, or troubleshooting .
• It is recommended that all personnel responsible for operation and
maintenance of this product read the precautions, maintenance,
and operation sections of this manual .
Installation Precautions
• Do not install system on line pressure above the rated pressure as
noted in System Specifications above .
• Do not install the system on a hot water line. Failure to limit the
water temperature to 100°F (38
°
C) can result in housing failure and
property damage .
• Do not connect the system backwards with the feed water line
connected to the outlet .
• Do not use liquid pipe thread compounds for threaded connec-
tions . Use Teflon
®
tape only .
• Do not solder plumbing connections that are attached to the hous-
ings or inlet/outlet fittings . System damage may occur due to high
temperature .
• Do not allow the system to freeze. Turn off water supply and drain
the system if temperature falls below 32°F (0
°
C) .
• Do not install system in direct sunlight or where the system will be
exposed to harsh chemicals or may be subjected to being hit by
moving equipment, carts, mops, or any other item that may cause
damage .
• Allow 3" (76mm) minimum clearance under the housings for filter
replacement .
• If water hammer is evident, install water hammer arrestors before
the system .
• Do not over tighten fitting connections.
• Always back up valves and fittings with a wrench when installing
fittings to avoid over tightening or loosening existing fittings .
• Do not install the unit behind equipment where it may be difficult to
access the system for future filter replacements .
Position the system in a suitable location . The direction of flow
through the system is left to right . Keep this in mind when determin-
ing installation locations . Do not mount the system near any source
of heat . Also do not mount this system over anything that may be
adversely affected by water .
Teflon
®
is a registered trademark of E .I . DuPont de Nemours & Company .
Replacement Filters
System Replacement Filters
System Model Filter Ordering Code Frequency
Description
Cold Bev
Max-S2
CLDBMX-S2S-PM
6 Months
All Filters for System Maintenance
CLDBMAXR-S-CB
6 Months
10" Slimline Coconut Shell Carbon Block (2)
Cold Bev
Max-S2L
CLDBMX-S2L-PM
6 Months
All Filters for System Maintenance
CLDBMAXR-L-CB
6 Months
20" Slimline Coconut Shell Carbon Block (2)
Cold Bev
Max-S3L
CLDBMX-S3L-PM
6 Months
All Filters for System Maintenance
CLDBMAXR-L-CB
6 Months
20" Slimline Coconut Shell Carbon Block (3)
Cold Bev
Max-S1BBL
CLDBMX-S1B-PM
6 Months
All Filters for System Maintenance
CLDBMAXR-BL-CB 6 Months
20" Big Blue Coconut Shell Carbon Block (1)
Cold Bev
Max-S2BBL
CLDBMX-S2B-PM
6 Months
All Filters for System Maintenance
CLDBMAXR-BL-CB 6 Months
20" Big Blue Coconut Shell Carbon Block (2)
Cold Bev
Max-S3BBL
CLDBMX-S3B-PM
6 Months
All Filters for System Maintenance
HSR-BL-ACRAF
6 Months
20" Big Blue GAC Filter (1)
CLDBMAXR-BL-CB 6 Months
20" Big Blue Coconut Shell Carbon Block (2)
Filter Cartridge Life Span
Filter cartridges should be changed at end of filter life, due to lack of
filtering performance, or whenever a 15 psi pressure drop or greater is
experienced during normal operation, whichever comes first .
Filter Placement Reference
When replacing filters in a Cold Bev Max system note that all car-
bon block filter cartridges for that system are the same and can be
installed in any order . If a GAC radial flow cartridge is part of the
replacement filter cartridge kit it should be placed in the first housing
on the left .
Please note:
Cartridge capacities are estimates and may be less
depending on incoming water quality .
Содержание Hydro-Safe Cold Bev Max-S2
Страница 4: ...4 Cold Bev Max S2 Cold Bev Max S2L Cold Bev Max S3L Cold Bev Max S1BBL ...
Страница 6: ...Notes ...
Страница 7: ...Notes ...