2

System Specifications

Maximum Pressure:
Slimline Systems - 125 psi (8 .6 bar), Cold Bev Max Models S2, S2L, 

S3L
Big Blue Systems - 90 psi (6 .2 bar), Cold Bev Max Models S1BBL, 

S2BBL, and S3BBL
Maximum Temperature: 100°F (38°C)
Inlet/Outlet Connections: 3/8" (10mm) NPT for Slimline Models,  

3/4" (20mm) NPT for Big Blue Models .
pH 6 .5 to 8 .5
Chlorine < 2ppm
Iron (maximum) 0 .3 mg/l
Manganese (maximum) 0 .05 mg/l
Oil & H2S- None allowed
For all other feed water quality requirements abide by the current 

USEPA Safe Drinking Water Act standards .
Maximum Flow Rate: 

System Flow Rate

System Model

Flow Rate

Cold Bev Max-S2

1 GPM

Cold Bev Max-S2L

2 GPM

Cold Bev Max-S3L

2 GPM

Cold Bev Max-S1BBL

6 GPM

Cold Bev Max-S2BBL

6 GPM

Cold Bev Max-S3BBL

6 GPM

Cold Bev Max line is available in different configurations depending 

upon filtration and flow requirements . 
Slimline models use 2

¾"

  (70mm) in diameter filters and are available 

in either 10" (250mm) or 20" (500mm) length options .  The slimline 

models are equipped with 3/8" (10mm) NPT fittings .
Big Blue models use 4½" diameter filters and are available in either 

10" (250mm) or 20" (500mm) length options . The Big Blue models 

are equipped with 3/4" (20mm) NPT fittings .

Notice to Installer

•  Do not discard this manual after installation. This manual contains 

important operation, maintenance and precautionary information . 

Please present this manual to the user/owner/operator after instal-

lation .

•  It is strongly suggested that you read this manual before installing 

system to ensure the best possible installation .

•  Installation must comply with all local and state plumbing codes 

and regulations . 

•  Connect the system to cold water supply only. Water Temperature 

cannot exceed 100°F (37°C) .

•  System must be installed in a vertical, upright and level position. 
•  Do not use with water that is microbiologically unsafe or of un-

known water quality .

•  Notice to user/owner/operator: Please retain this manual for future 

reference for parts, maintenance, or troubleshooting .

•  It is recommended that all personnel responsible for operation and 

maintenance of this product read the precautions, maintenance, 

and operation sections of this manual .   

Installation Precautions

•  Do not install system on line pressure above the rated pressure as 

noted in System Specifications above .

•  Do not install the system on a hot water line. Failure to limit the 

water temperature to 100°F (38

°

C) can result in housing failure and 

property damage .

•  Do not connect the system backwards with the feed water line 

connected to the outlet . 

•  Do not use liquid pipe thread compounds for threaded connec-

tions . Use Teflon

®

 tape only .

•  Do not solder plumbing connections that are attached to the hous-

ings or inlet/outlet fittings . System damage may occur due to high 

temperature .

•  Do not allow the system to freeze. Turn off water supply and drain 

the system if temperature falls below 32°F (0

°

C) . 

•  Do not install system in direct sunlight or where the system will be 

exposed to harsh chemicals or may be subjected to being hit by 

moving equipment, carts, mops, or any other item that may cause 

damage . 

•  Allow 3" (76mm) minimum clearance under the housings for filter 

replacement . 

•  If water hammer is evident, install water hammer arrestors before 

the system . 

•  Do not over tighten fitting connections. 
•  Always back up valves and fittings with a wrench when installing 

fittings to avoid over tightening or loosening existing fittings . 

•  Do not install the unit behind equipment where it may be difficult to 

access the system for future filter replacements . 

Position the system in a suitable location . The direction of flow 

through the system is left to right . Keep this in mind when determin-

ing installation locations . Do not mount the system near any source 

of heat . Also do not mount this system over anything that may be 

adversely affected by water .  

Teflon

®

 is a registered trademark of E .I . DuPont de Nemours & Company .

Replacement Filters

System Replacement Filters

System Model Filter Ordering Code Frequency

Description

Cold Bev  
Max-S2

CLDBMX-S2S-PM

6 Months

All Filters for System Maintenance

CLDBMAXR-S-CB

6 Months

10" Slimline Coconut Shell Carbon Block (2)

Cold Bev  
Max-S2L

CLDBMX-S2L-PM

6 Months

All Filters for System Maintenance

CLDBMAXR-L-CB

6 Months

20" Slimline Coconut Shell Carbon Block (2)

Cold Bev  
Max-S3L

CLDBMX-S3L-PM

6 Months

All Filters for System Maintenance

CLDBMAXR-L-CB

6 Months

20" Slimline Coconut Shell Carbon Block (3)

Cold Bev  
Max-S1BBL

CLDBMX-S1B-PM

6 Months

All Filters for System Maintenance

CLDBMAXR-BL-CB 6 Months

20" Big Blue Coconut Shell Carbon Block (1)

Cold Bev  
Max-S2BBL

CLDBMX-S2B-PM

6 Months

All Filters for System Maintenance

CLDBMAXR-BL-CB 6 Months

20" Big Blue Coconut Shell Carbon Block (2)

Cold Bev  
Max-S3BBL

CLDBMX-S3B-PM

6 Months

All Filters for System Maintenance

HSR-BL-ACRAF

6 Months

20" Big Blue GAC Filter (1)

CLDBMAXR-BL-CB 6 Months

20" Big Blue Coconut Shell Carbon Block (2)

Filter Cartridge Life Span

 

Filter cartridges should be changed at end of filter life, due to lack of 

filtering performance, or whenever a 15 psi pressure drop or greater is 

experienced during normal operation, whichever comes first .

Filter Placement Reference

When replacing filters in a Cold Bev Max system note that all car-

bon block filter cartridges for that system are the same and can be 

installed in any order . If a GAC radial flow cartridge is part of the 

replacement filter cartridge kit it should be placed in the first housing 

on the left . 

Please note:

 Cartridge capacities are estimates and may be less 

depending on incoming water quality .

Содержание Hydro-Safe Cold Bev Max-S2

Страница 1: ... future reference Table of Contents System Specifications 2 Replacement Filters 2 Notice to Installers 2 Installation Precautions 2 Operation 3 Installation 3 Maintenance 3 Filter Cartridge Replacement Procedure 3 Replacement Parts List 3 System Drawings 4 Limited Warranty 6 Cold Bev Max 2BBL Note Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfe...

Страница 2: ... inlet outlet fittings System damage may occur due to high temperature Do not allow the system to freeze Turn off water supply and drain the system if temperature falls below 32 F 0 C Do not install system in direct sunlight or where the system will be exposed to harsh chemicals or may be subjected to being hit by moving equipment carts mops or any other item that may cause damage Allow 3 76mm min...

Страница 3: ... and allow it to run to drain for 5 minutes to flush the system then close the valve 9 Open the outlet water valve and check for leaks 10 Record the start up date and pressure gauge values in system maintenance log Note Overtightening components can damage the system causing water damage and or system failure Maintenance Routine maintenance of this system involves periodic filter changes Filter ca...

Страница 4: ...4 Cold Bev Max S2 Cold Bev Max S2L Cold Bev Max S3L Cold Bev Max S1BBL ...

Страница 5: ...5 Cold Bev Max S2BBL Cold Bev Max S3BBL Note Allow 3 76mm of clearance at bottom of system for removal of filterbowls for filter cartridge replacement ...

Страница 6: ...Notes ...

Страница 7: ...Notes ...

Страница 8: ...and exclusive remedy for breach of warranty and the Company shall not be responsible for any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage f...

Отзывы: