3  Technical data

Hydraulic performance data

Max. operating pressure 

6 bar 

Ambient temperature

 -2 °C to +40 °C (

observe pump specification!

)

Operating temperature

 +2 °C to +90 °C (

observe pump specification!

)

Opening pressure of gravity brake

10 mbar

Kvs mixing valve

4,5

Temperature display area

0 - 120 °C

Temperature setting area

20-43 °C / 20-55 °C / 30-70

     

 °C  (

depending on type of thermostatic mixing valve

)

Media

Water / water-glycol mixtures according to VDI 2035/ÖNORM H 5195

Electrical connection

Power supply

See separate pump documentation!

Dimensions

Width x height x depth with EPP shell

300 x 370 x 240  mm

Axis center distance

125 mm

Sealing surfaces distance

342,5 mm

Connections to pipe network

Heating circuit (top)

11/2" AG male connection; flat sealing. Fitting 11/2" Union nut  x 1" IG female connection

Boiler circuit (bottom)

11/2" male connection; flat sealing

Tightening torques for screwed connections

3/4" 

  35 Nm

1"

  55 Nm

11/4"

  90 Nm

11/2"

130 Nm

Material

Fittings

brass CW617N

Pipes

galvanized steel Ø48 mm

Plastics

impact resistant and temperature resistant

Flat seals

AFM 34/2

Bypass pipe

brass CW617N

Gravity brake

POM. NBR. stainless steel

O-rings

EPDM

Insulation

EPP

Wall bracket

Galvanized steel sheet

Circulation pump

The technical data on the circulating pumps can be found in the respective pump documentation.

Содержание FlowBox HKF25 Series

Страница 1: ...Series HKF25 Pump mixing valve group with thermostatic fix point control for heating systems Installation and Operating Manual WattsWater eu ...

Страница 2: ...tion of Conformity according to the Machinery Directive 2006 42 EC has been issued for this pump group product 1 3 Product features stable mounting bracket including mounting hardware patented 3 piece EPP insulating shell compact space saving design Contents 1 General information 2 1 1 Important information 2 1 2 Product conformity 2 1 3 Product features 2 2 Safety 3 2 1 Presentation of the safety...

Страница 3: ...mp group is not intended to be operated by people including children with physical sensory or mental disabilities nor by people with insufficient experience or previous knowledge 2 4 Foreseeable misuse The following is considered to be foreseeable misuse operating the pump group contrary to the specifications improper use of the pump group modifications to the pump group that were not agreed with ...

Страница 4: ...tation Dimensions Width x height x depth with EPP shell 300x370x240 mm Axis center distance 125 mm Sealing surfaces distance 342 5 mm Connections to pipe network Heating circuit top 11 2 AG male connection flat sealing Fitting 11 2 Union nut x1 IG female connection Boiler circuit bottom 11 2 male connection flat sealing Tightening torques for screwed connections 3 4 35 Nm 1 55 Nm 11 4 90 Nm 11 2 1...

Страница 5: ... HKF25 IM DE W UK 11 2020 Rev 0 Part no 10027337 5 Overall dimensions 240 5 370 384 125 125 300 G11 2 G11 2 Rp1 Rp1 40 130 130 4 Pressure loss curve 1 10 100 1 000 100 10 000 1 000 Flow rate l h Pressure loss mbar ...

Страница 6: ...k Work on parts carrying live voltage must only be carried out by trained electricians Disconnect the power supply of the system and secure it against being switched back on before carrying out any installation mainte nance cleaning or repair work The installation and commissioning of the pump group must only be carried out by trained personnel who have been authorized by the manufacturer Take car...

Страница 7: ...nd return lines and check that all screw connections are tight 7 3 Initial Commissioning Requirement The pump group is completely assembled Connection of the power supply 1 Connect the power supply see separate pump documentation 9 9 The pump group switches on automatically after being connected to the power supply 2 Vent the heating system The pump group must be switched off during the ventilatio...

Страница 8: ...ittings 2 Loosen the nuts on the pump bottom connection and remove the distance tube 3 Turn the pump and the flow ball valve by 180 degrees 4 Loosen the nut on the return ball valve and turn the ball valve through 180 degrees 5 Rotate the pump group by 180 degrees and tighten all connections and fittings The supply line is now on the left side 6 Tighten the loosened connections to the pump and bal...

Страница 9: ... and retighten sealing connec tions or replace seals as required 2 Functional checks Check that settings and operating and performance parameters are set correctly Check flow noise during operation Ask users if there are any noticeable problems 3 Ball taps Check that stop valves and ball taps can move freely 4 Pump Pay attention to the noise of the pump 5 Thermostatic mixing valve Check the thermo...

Страница 10: ...o the hot medium when emptying 8 4 Installation of the circulation pump 1 Replace damaged or defective seals if necessary 2 Insert the circulation pump and tighten the nuts X for tightening torques see Technical data on page 4 3 Connect the wiring of the circulation pump 4 Slowly open the ball valves by turning the thermometer handle 5 Slowly pressurize the pump assembly and vent the system if nec...

Страница 11: ... 5 Dismantle the thermostatic mixing valve A with tempera ture setting by loosening the union nuts X 8 6 Installation of the thermostatic mixing valve 1 Replace damaged or defective seals if necessary 2 Insert the thermostatic mixing valve A and tighten the nuts X for tightening torques see Technical data on page 4 3 Slowly open the ball valves by turning the thermometer handle 4 Restore the power...

Страница 12: ...ble the pump group or commission a specialist company with this task 3 Sort the subassemblies and component parts into recyclable materials and operating materials 4 Dispose of the subassemblies and components according to regional laws and regulations or take them to be recycled 9 1 Return shipment to the manufacturer Get in contact with the manufacturer if you would like to return the pump group...

Отзывы: