Series WDS-SI and LFWDS-SI

FloodSafe

®

 Water Detector Shutoff

Sizes:  

3

 ⁄

4

" and 1" (20 and 25mm)

Please read all instructions, identify all components and read all warnings prior to beginning the installation of this product.
This product is intended to prevent catastrophic water damage in the event of a water heater leak. 

Please Note: 

During an emergency operating condition, the temperature and pressure relief valve installed on your water heater can 

discharge an excessive amount of water. It is designed to protect your home or business from the potential danger of explosion. Upon 

detection of this discharged water, the FloodSafe

®

 Water Detector Shutoff shuts off both the supply of water and the source of power 

(gas, oil or electricity) to the water heater, preventing a very dangerous situation.
The FloodSafe

®

 Water Detector Shutoff also contains an audible & visual alarm and contacts for monitored alarm systems. It is a reset-

table device and can be tested at any time to ensure proper operation.

Parts Included

Important Note: 

Thermostat wiring is required and must be supplied by the installer.

Planning Your Installation:

The Water Detector Shutoff should be installed within 6 to 12 inches of the water heater on the cold water inlet supply pipe.

The Control Unit, which houses the circuitry for the operation of the valve, contains interlocking connectors for the Water Detector Pad, 

the Power Supply and remote alarm and the Power Cutout Module. The cables provided should not be cut or extended; therefore, 

remote installation is not recommended.
The Water Detector Pad supplied with the Water Detector Shutoff should be located as close to the water heater as possible. It is not 

necessary to remove the cover of the Control Unit to install the interconnecting cables. 

Flooring Surface:

 

 Dirt flooring –

 A metal or plastic drain pan must be installed under the water heater. Position the Water Detector Pad inside the 

drain pan.

 

 Cement floor – 

Install the Water Dam provided with the Water Detector Shutoff installation kit around the outside diameter of the 

water heater. Position the Water Detector Pad inside the Water Dam.

 

 Attic installation – 

A metal or plastic drain pan must be installed under the water heater. Position the Water Detector Pad inside 

the drain pan.

Please be certain to follow all local codes when installing this device.

Control Unit

Power Cutout Module

Power Supply

Water Detector Pad

Water Dam

Power Cutout Cable & Pocket Screwdriver

IS-WDS-SI

Содержание FloodSafe WDS-SI Series

Страница 1: ...er Detector Shutoff should be installed within 6 to 12 inches of the water heater on the cold water inlet supply pipe The Control Unit which houses the circuitry for the operation of the valve contains interlocking connectors for the Water Detector Pad the Power Supply and remote alarm and the Power Cutout Module The cables provided should not be cut or extended therefore remote installation is no...

Страница 2: ...sary to remove the cover of the Control Unit to install the interconnecting cables To remove an interlocking cable use the supplied Pocket Screwdriver to depress the tab on the cable while pulling cable from its socket Figure 4 Important Interconnecting wires must not touch or be in close proximity to any flame or hot surface a If no drain pan exists install the Water Dam around the perimeter of t...

Страница 3: ...f the cable Connect the cable from the Power Cutout Module Figure 14 Terminal C common to the SPARK terminal of the Electronic Control and NO normally open to the Pilot Electrode Assembly as indicated in Diagram 2 Figures 12 and 13 Note We have made every effort to provide all of the hardware required for a complete installation However the terminal connections used to connect the Pilot Electrode ...

Страница 4: ... to the Control Unit can occur Exceeding the current rating will void the warranty Figure 18 IMPORTANT Do not insert the Power Supply into the 120 VAC outlet until the installation is complete 7 Insert the green circuit board connector into the Control Unit Figure 19 8 Check the position of the valve reset located on the front of the Control Unit The slots should indicate the valve is in the open ...

Страница 5: ...3 If all of the above functions take place the unit can be reset To Reset the Control Unit 1 Remove the Water Detector Pad from the drain pan or Water Dam and wipe the moisture from the green circuit board 2 Wipe any water from the drain pan or Water Dam 3 Reposition the Water Detector Pad on the floor or in the drain pan 4 Turn the valve position indicator on the Control Unit to the open position...

Отзывы: