Add-on and Retrofit Sensor Connection Kits

For Building Management Systems

ORDERING CODE

ADD-ON/RETROFIT KIT

DESCRIPTION

88009431

FP-FBF-BMS
BMS Flood Sensor Connection Kit
Series 860 Small, LF860 Small
Sizes ½" to 2"

Includes sensor activation module with cable, power adapter, and ground wire. 
Use this kit to activate the flood sensor and enable flood detection capabilities 
on the relief valve of a new installation in a BMS configuration.

88009425

FP-RFK-FBF-BMS-CFS
BMS Flood Sensor Retrofit 
Connection Kit
Series 860 Small, LF860 Small 
Sizes ½" to 2"

Includes flood sensor (2), sensor activation module with cable, power adapter, 
and ground wire. Use this kit to add flood detection capabilities to the relief 
valve of an existing installation in a BMS configuration.

For Cellular Communication

ORDERING CODE

ADD-ON/RETROFIT KIT

DESCRIPTION

88009432

FP-FBF-CFS
Cellular Flood Sensor Connection Kit
Series 860 Small, LF860 Small
Sizes ½" to 2"

Includes sensor activation module with cable, Cellular Gateway with mounting 
kit, power adapter, and ground wire. Use this kit to activate the flood sensor 
and enable flood detection capabilities as well as e-mail, text, and voice noti-
fications.

88009426

FP-RFK-FBF-CFS
Cellular Flood Sensor Retrofit Connection Kit
Series 860 Small, LF860 Small 
Sizes ½" to 2"

Includes flood sensor (2), sensor activation module with cable, Cellular Gateway 
with mounting kit, power adapter, and ground wire. Use this kit to add flood 
detection capabilities to the relief valve of an existing installation and enable 
e-mail, text, and voice notifications.

Содержание FEBCO 860 Series

Страница 1: ...s to discourage tampering or install a protective enclosure to discourage vandals When opting for an enclosure install the protective cover so that adequate clearance is available for maintenance and...

Страница 2: ...ng assemblies of both check valves and open the inlet shutoff valve to allow sufficient flow of water through the assembly Clear all sand debris and other particles from the line If debris in the wate...

Страница 3: ...semblies are disassembled and reassembled in the same manner To service the checks replace the check modules with new ones by using check module assembly kits available from FEBCO Or replace the rubbe...

Страница 4: ...e from the relief valve assembly may not indicate a relief valve failure Water is discharged from the relief valve when the mainline check valves become fouled with foreign debris For more information...

Страница 5: ...may become folded or creased if the internal assembly is restricted while tightening the cylinder 7 Replace the O ring Item 20 in the relief valve cover Properly seat the round bead on the large diaph...

Страница 6: ...certain conditions relief valves can discharge water at rates greater than the air gap drain capacity 2 For an indoor installation locate the assembly near a floor drain sized to adequately handle dis...

Страница 7: ...Seat Ring RV 1 12 1 Gasket Ring RV 1 13 Spring RV 1 14 Seat Disc RV 1 15 Diaphragm RV 1 16 Outer Diaphragm RV 1 17 Small Piston RV 1 17 1 Round HD Screw RV 1 17 2 Washer RV 1 17 3 Hex Nut RV 1 18 Cyl...

Страница 8: ...1 1 4 2 32 50 Both checks Kit includes Items 2 2 3 1 qty 2 and 5 qty 2 Relief Valve Rubber Kit 905345 ALL 1 2 3 4 15 20 905345 ALL 1 25 905346 ALL 1 1 4 2 32 50 Kit includes Items 12 12 1 14 15 16 18...

Страница 9: ...se the outlet ball valve After clearing the system with air partially open the outlet ball valve 7 Leave all drain valves test cocks and ball valves in the half open half closed position for the winte...

Страница 10: ...line pressure variations causing relief valve to discharge Eliminate or reduce pressure variations by installing a soft seated spring loaded check on upstream side of device Pressure surges water hamm...

Страница 11: ...capabilities to the relief valve of an existing installation in a BMS configuration For Cellular Communication ORDERING CODE ADD ON RETROFIT KIT DESCRIPTION 88009432 FP FBF CFS Cellular Flood Sensor C...

Страница 12: ...damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or...

Отзывы: