Thank you for your purchase of a state of the art Watts Premier Reverse Osmosis (RO) water treatment system.

 Water 

quality concerns are becoming more of a focus for the public.  You may have heard about contaminants in the drinking water, 
such as Arsenic, Perchlorate, Chromium, Cryptosporidium or Giardia.  There may also be some local water issues such as 
high levels of Lead and Copper. This Watts Premier water treatment system has been designed and tested to provide you 
with high quality drinking water for years to come.  The following is a brief overview of the system.

Your Reverse Osmosis System:

Osmosis is the process of water passing through a semi permeable membrane in order to balance the concentration of 
contaminants on each side of the membrane. A semi permeable membrane is a barrier that will pass some particles like clean 
drinking water, but not other particles like arsenic and lead. 

Reverse osmosis uses a semi permeable membrane; however, by applying pressure across the membrane, it concentrates 
contaminants (like a strainer) on one side of the membrane, producing crystal clear water on the other. This is why RO 
systems produce both clean drinking water and rinse water that is fl ushed from the system. This reverse osmosis system also 
utilizes carbon block fi ltration technology, and can therefore provide a higher quality drinking water than carbon fi ltration 
systems alone. 

Your system is a three or four stage RO which is based upon separate treatment segments within the one complete water 
fi ltration system. These stages are as follows:
  

Stage 1 (Not in three stage units) – Sediment fi lter, recommended change 6 months.

The fi rst stage of your RO system is a fi ve micron sediment fi lter that traps sediment and other particulate matter 
like dirt, silt and rust which affect the taste and appearance of your water. 

Stage 2 – Carbon fi lter, recommended change 6 months.

The second stage contains a 5 micron carbon block fi lter.  This helps ensure that chlorine and other materials that 
cause bad taste and odor are greatly reduced.  

Stage 3- Membrane, recommended change 2-5 years.

Stage three is the heart of the reverse osmosis system, the RO membrane.  This semi permeable membrane will 
effectively take out TDS,  Sodium and a wide range of contaminants such as Percholate, Chromium, Arsenic, Copper, 
Lead as well as Cysts, such as Giardia and Cryptosporidium.  Because the process of extracting this high quality 
drinking water takes time, your RO water treatment system is equipped with a storage tank.  

Stage 4- Carbon post fi lter, recommend change 6 - 12 months.

 The 

fi nal stage is a high quality carbon fi lter.  Drinking water enters this fi lter after the water storage tank and it is   

 

used as a fi nal polishing fi lter.  

Note: 

Filter life may vary based upon local water conditions or use patterns.

System Maintenance

Just because you can not taste it, does not mean that it is not there. Contaminants such as Lead, Chromium and Arsenic are 
undetectable to the taste.  Additionally, over time if you do not replace the fi lter elements, other bad tastes and odors will 
be apparent in your drinking water.  

This is why it is important to change out your fi lters at the recommended intervals as indicated in this system manual.  When 
replacing the fi lter elements, pay special attention to any cleaning instructions. Should you have any further questions please 
refer to our website at 

www.wattspremier.com

 or call our customer service dept. at 

1-800-752-5582.

Available From:

®

freshwater

systems

.com

serving you since 1989

CLICK HERE

Содержание RO-PURE

Страница 1: ...for future reference Warning Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure and possible damage to property Manual Edition 08 21 07 P N 199404 Model RO PURE System Tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance ...

Страница 2: ...urchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months Carbon Post Filter 6 months Model Number __________ Serial Number ___________ ...

Страница 3: ...fety of your personal information Watts Premier collects personal information when you register with Watts Premier This information is stored in our data base and we do not rent sell or share personal information with other people or nonaffiliated companies We reserve the right to send you certain types of communications such as direct mail email or by telephone relating to our products or product...

Страница 4: ...of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appearance of your water Stage 2 Carbon filter recommended change 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membran...

Страница 5: ...Faucet in a Porcelain Sink 7 Punch a Hole for the Faucet in a Stainless Steel Sink 7 Watts Chrome Monitor Non Monitored Faucet Installation 8 Green Tube Connection From RO Module To The Adapta Valve 9 Adapta Valve Installation 9 Reverse Osmosis Module Mounting 9 Drain Saddle Installation 10 Tank Ball Valve Installation 10 How To Use Quick Connect Fittings For Tubing Connections 11 Blue Tube Connec...

Страница 6: ...iver Needle Nose Pliers Adjustable Pliers Electric Drill 1 8 1 4 3 8 Drill Bits Contents of Reverse Osmosis RO System Operating Temperatures Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 85 psi 7 43 g cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5NTU Note Reverse Osmosis water should not be...

Страница 7: ...arp edges with a file Step 1 Step 2 Drill a Hole for the Faucet in a Porcelain Sink Most sinks are predrilled with 1 or 1 diameter hole that you can use for your RO faucet If you are already using it for a sprayer or soap dispenser you will need an additional hole for the faucet Porcelain sinks are extremely hard and can crack or chip easily Use extreme caution when drilling Premier accepts no res...

Страница 8: ...both the red and green lights will flash to indicate that both lights are functional Thereafter it will flash green only when the faucet handle is turned to the ON position When your system is ready to be serviced approximately six months you will see the light flash red when the handle is turned to the ON position Refer to the Six Month Maintenance page 14 section of this manual for filter replac...

Страница 9: ...the RO Module after the Adapta Valve has been installed Remove a brass nut plastic sleeve and brass insert from the parts bag Place nut on the green tube coming from the RO Module first then the plastic sleeve small taper end of plastic sleeve must point to the end of tube and then insert the brass insert into the end of the tube Insert the green tube into the opening on the Adapta Valve supplied ...

Страница 10: ...either above the disposal or if a second sink drain is available install it above the cross bar on the second sink Installation of the drain line near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Watts offers drain line installation kits that can be used with garbage disposals part numbers 164014 and 164020 Assemble the drain saddle around...

Страница 11: ...burrs and sharp edges be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a permanent leak proof seal Pull on the tube to check that it is secure It is a good practice to test the sy...

Страница 12: ...saddle and tighten the black nut securely This is a gravity fed line if there is any dip or kink in the tube the rinse water will not flow into the drain properly Water will back up and come out the air gap hole in the back of the faucet base The tubing must be as SHORT and STRAIGHT as possible making a downward slope from faucet to drain saddle to allow for proper drainage Step 26 Note Note Step ...

Страница 13: ...rature and pressure After the tank has filled open the RO An optional ice maker kit not included may be purchased from Watts Premier by calling 1 800 752 5582 or buy on line at www wattspremier com If system is connected to an ice maker turn the ice maker off or do not allow water to flow to the ice maker until Step 3 flushing is complete and the tank has been allowed to completely fill Connection...

Страница 14: ...mbranes have a life expectancy of between 2 and 5 years depending on the incoming water conditions and the amount of use of the RO system Normally a membrane would be replaced during a semiannual or annual filter change However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to replace the membrane A water sample may be...

Страница 15: ... 4 Filter Cartridges 2 125089 FITTING ELBOW 90 QC 1 4TX1 4I 3 622036 FLOW RESTRICT 550 STAND ALONE 4 134003 VALVE SHUT OFF 1 4 Q C RES 5 119007 TANK 3 GALLON METAL WHITE 7 134007 ADAPTA VALVE 8 116074 FAUCET AG WATTS CHROME MONITOR 9 134018 VALVE BALL ELB 1 4QCX1 4F The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of total dissolved solids ...

Страница 16: ...be clogged Caused from dishwasher or garbage disposal Disconnect the 3 8 black line at the drain clean the 3 8 black line out with a wire then reconnect Blowing air through the line will not always remove the clog 5 Small amount of water in System starting up Normally it takes 6 10 hours to fill tank Note low storage tank incoming water pressure and or temperature can drastically reduce production...

Страница 17: ...7 24 50psi 4 3 27 0 10 10 0 Nitrite 3 1 0 41 86 0 7 24 50psi 0 46 3 0 10 1 0 Nitrate Nitrite 30 4 2 86 0 7 24 50psi 4 8 30 0 10 10 0 Perchlorate 0 14 0 003 97 0 7 39 50psi 0 005 mg L 0 10 10 0 006 Radium 226 228 25pCi L 5pCi L 80 0 7 24 50psi 5pCi L 25pCiL 10 5pCiL Selenium 94 85 0 2 97 0 7 24 50psi 0 2 0 10 10 0 05 TDS 741 22 97 0 7 28 50psi 26 0 750 40mg L 187 Recovery 15 77 Daily Production Rat...

Страница 18: ... from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water system This Watts Premier reverse osmosis system is designed to remove up to 98 of pentavalent arsenic It will not convert trivalent arsenic to pentavalent arsenic Under laboratory standard testing conditions this system reduced 0 30 mg L ppm pentavalent arsenic to under 0 010 mg...

Страница 19: ...t that turns red to notify you for filter replacement Part No 116000 Chrome Non Monitored 49 95 each 116072 Brushed Nickel Non Monitored 59 95 each 116074 Chrome Monitored 69 95 each Watts Premier Hot Water Recirculation Pump Bring convenience and saving to your home giving you hot water instantly at every faucet when you need it This unique product is easy to install and not only provides you wit...

Страница 20: ...pres sure which may exceed readings during the day High pressure readings may indicate the need for pressure regulator to prevent damage to appliances Part No 261003 14 95 each Whole House Filter Great for sediment problems such as in well water supply or areas where dirt and rust particles are a problem Includes three 50 Micron sediment filters and wrench 3 4 ports Part No 500223 86 95 each Repla...

Страница 21: ...Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 Part No 107075 14 95 pk All In One reversible High Flow Filter Deluxe 5 Way Massaging Spray Replacement filter Soft Touch Adjustment Pads Anti Scaling Spray Nozzle High Strength Housing Triple Plated Finish Cartridge Life Rating 6 months Part No 107098 White Chrome 47 50 Part No 107080 18...

Страница 22: ...ot be lower than 2 or higher than 11 5 The incoming water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system This warranty does ...

Отзывы: