Watts Premier Inc.
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
California Certification # 07-1882
RO-Pure
System conforms to NSF Standard 58 for specific claims.
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description Change
time
Frame
Sediment Pre-filter:
#105311
6 Months
Carbon Pre-filter:
#105351
6 Months
Post Carbon filter
#105341
12 Months
50 GPD R.O. Membrane:
#105331
2 to 5 years
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58. This
system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
Avg. In.
Avg. Eff.
% Reduction pH
Pressure
Max Eff.
Inf. challenge
Max Allowable
(mg/L)
(mg/L) mg/L
concentration
concentration
mg/L
mg/L
Arsenic (Pentavalent)
.310
0.001
99.6%
7.24
50psi
0.002
0.30±10%
0.010 mg/L
Barium Reduction
9.2
0.08
99.0%
7.64
50psi
0.12
10.0±10%
2.0
Cadmium Reduction
0.031
0.0004
98.0%
7.49
50psi
0.0008
0.03±10%
0005
Chromium (Hexavalent)
0.30
0.002
99.0%
7.24
50psi
0.004
0.03±10%
0.1
Chromium (Trivalent)
0.30
0.001
99.0%
7.64
50psi
0.002
0.03±10%
0.1
Copper Reduction
3.2
0.02
99.0%
7.40
50psi
0.04
3.0±10%
1.3
Cysts
92,000#/ml
3 #/ml
99.99%
7.44
50psi
18 minimum 50,000/mL
N/A
Fluoride Reduction
8.7
0.19
97.0%
7.24
50psi
0.3
8.0±10%
1.5
Lead Reduction
0.15
0.002
98.8%
7.39
50psi
0.005
0.15±10%
0.0107
Nitrate
27
3.8
86.0%
7.24
50psi
4.3
27.0 ±10%
10.0
Nitrite
3.1
0.41
86.0%
7.24
50psi
0.46
3.0 ±10%
1.0
N Nitrite
30
4.2
86.0%
7.24
50psi
4.8
30.0 ±10%
10.0
Radium 226/228
25pCi/L
5pCi/L
80.0%
7.24
50psi
5pCi/L
25pCiL±10%
5pCiL
Selenium
94.85
<0.2
97.0%
7.24
50psi
<0.2
0.10±10%
0.05
TDS
741
22
97.0%
7.28
50psi
26.0
750±40mg/L
187
Turbidity
11.3
0.1
99.0%
7.43
50psi
0-1
11±1mg/L
0.5NTU
Recovery - 15.77%
Daily Production Rate - 18.43 GPD
Efficiency - 8.82%
Depending on water chemistry, water temperature, and water pressure Watts Premier’s R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the
storage tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: (480) 675-7995 Fax: (623) 866-5666 Email: [email protected]
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
2. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is
certified for nitrite/nitrate reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. If your water supply is under 40 psi Watts Premier
recommends the use of a RO booster pump for proper operation.
3. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
4. Operating Water Pressure:
Maximum: 85 psi (6.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
5.
pH
2
to
11
6. Maximum Iron present in incoming water supply must be less than 0.2 ppm.
7. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
8. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.