CONTROL PROGRAMMING

INSTALLER (

I

) Displays/Settings

STEP 1

I

– 

Press NEXT and arrow up simulta-

neously for 3 seconds.

STEP 2

I

– 

Hardness: Set the amount of hard-

ness in grains of hardness as calcium carbonate
per gallon using, arrow down or arrow up but-
tons. The default is 20 with value ranges from 1
to 150 in 1 grain increments. Note the grains per
gallon can be increased if soluble iron needs to
be reduced. Press NEXT to go to step 3I. Press
REGEN to exit Installer Displays/Settings.

STEP 3

I

Day Override: When gallon capacity

is set to off, sets the number of days between
regeneration’s. When gallon capacity is set to
AUTO or to a number sets the maximum number
of days between regenerations. If value set to
“off” regeneration initiation is based solely on
gallons used. If value is set as a number (allow-
able range from 1 to 28) a regeneration initiation
will be called for on that day even if sufficient
number of gallons were not used to call for a
regeneration. Set Day Override using arrow

buttons to d

ays between

 regeneration

(1 to 28); or OFF.

Press NEXT to go to step 4

I

. Press REGEN to

return to previous step.

STEP 4

I

Next Regeneration Time (hour): Set

the hour of day for regeneration using down or up
arrow 

b

uttons. AM/PM toggles after 12. The

default time is 2:00 am. This display shows
“REGEN on 0 GAL” if “on 0” is selected in Step
9S or Step 7F. Press NEXT to go to step 5

I

.

Press REGEN to return to previous step.

STEP 5

I

Next RegenerationTime (minutes):

Set the minutes of day regeneration using 

the

arrow buttons. This display 

will 

not be shown if

“on 0” is selected in Step 9S or Step 7F. Press
NEXT to exit Installer Displays/ Settings. Press
REGEN to return to previous step.

To  initiate a manual regeneration immediately,
press and hold the “REGEN” button for three
seconds. The system will beam to regenerate
immediately. The control valve may be stepped
through the various regeneration cycles by
pressing the “REGEN” button.

General Operation

User (U) Displays/Settings

When the system is operating one of two displays will be
shown. Pressing NEXT will alternate between the displays.
One of the displays is always the current time of day. The 
second display is one of the following: days remaining or 
gallons remaining. Days remaining are the number of days
left before the system goes through a regeneration cycle.
Capacity remaining is the number of gallons that will be treat-
ed before the system goes through a regeneration cycle. The
user can scroll between the displays as desired.

If the system has called for a regeneration that will occur at
the preset time of regeneration, the words REGEN TODAY
will appear on the display.

When water is being treated (i.e. water is flowing through the
system) the word “Softening” flashes on the display.

REGENERATION MODE

Typically a system is set to regener-
ate at a time of low water usage. An
example of a time with low water
usage is when a household is asleep.
If there is a demand for water when the  system is regenerating,
untreated water will be used.

When the system begins to regenerate, the display will change
to include information about the step of the regeneration process
and the time remaining for that step to be completed. The system
runs through the steps automatically and will reset itself to pro-
vide treated water when the regeneration has been completed.

MANUAL 
REGENERATION

Sometimes there is a
need to regenerate
the system, sooner
than when the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage
because of guests or a heavy laundry day.

To initiate a manual regeneration at the preset delayed regener-
ation time, when the regeneration time option is set to “NORMAL”
or “ on 0”, press and release “REGEN”. The words
“REGEN TODAY” will flash on the display to indicate that the sys-
tem will regenerate at the preset delayed regeneration time. If
you pressed the “REGEN” button in error, pressing the button
again will cancel the request. Note: If the regeneration time
option is set to “on 0” there is no set delayed regeneration time
so “REGEN TODAY” will not activate if “REGEN” button is
pressed.

To initiate a manual regeneration immediately, press and hold the
“REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled.

Note: If brine tank does not contain salt, fill with salt
and wait at least two hours before regenerating.

Содержание WM100SM

Страница 1: ...OPERATING MANUAL WATER CONDITIONER with WM100SM valve WATER QUALITY CONDITIONING PRODUCTS...

Страница 2: ...tting Assemblies 31 Bypass Valve 32 Flow Diagrams Service and Backwash 33 Flow Diagrams Downflow and Upflow 34 Flow Diagrams Rinse and Fill 35 WS1 Wrench 36 System Troubleshooting 37 38 Valve Troubles...

Страница 3: ...ture often called ionized impurities which means they have an electrical charge The ion exchange process is based on the fact that like charges repel one another and unlike charges attract Calcium and...

Страница 4: ...et b 3 4 1 PVC solvent weld fitting c 1 straight brass sweat fitting d 3 4 straight brass sweat fitting Distributor Tube Opening 1 05 Diameter 3 4 U S PVC Pipe Size Tank Thread 2 1 2 8 NPSM Control Va...

Страница 5: ...does not need batteries When the control valve is used as a down flow softener two backwashes always occur The softener will start regenerant prefill before regeneration the prefill starts two hours b...

Страница 6: ...k over flow to drain This is a gravity drain designed to divert brine to the drain in the event of a malfunction which would cause overflow of the brine tank Be sure inlet outlet isolating valves are...

Страница 7: ...ling sweat copper follow state and federal codes by using a lead free solder and flux Use a joint compound to seal threaded pipe Some homes use the cold water pipes for an elec trical ground metal onl...

Страница 8: ...nuts on installation fittings Hand tighten only Split ring retainer design holds the nut on and allows load to be spread over the entire nut surface area reducing the chance for leakage The split rin...

Страница 9: ...Mode Figure 13 Bypass Mode Figure 14 Bypass Mode Figure 9 Brine Draw Connection STEP 5 Start up Place the bypass valve in the bypass position or mode see figures 12 14 below Open the main water supply...

Страница 10: ...y reaches zero 2 Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control by pressi...

Страница 11: ...isplays is always the current time of day The second display is one of the following days remaining or gallons remaining Days remaining are the number of days left before the system goes through a reg...

Страница 12: ...s may require periodic disinfecting Components The control valve consists of the following components 1 Drive Assembly 2 Drive Cap Assembly Main Piston and Regenerant Piston 3 Spacer Stack Assembly 4...

Страница 13: ...es the velocity of the water cre ating a zone of negative pressure that draws in the concentrated liquid regenerant such as sodium chloride brine potassium permanganate sodium hydroxide hydrochloric a...

Страница 14: ...orts etc The installation fitting assemblies are sold in pairs and consist of two fittings two nuts two split rings and two o rings The installation fitting assemblies and the bypass valve are sold se...

Страница 15: ...te Lift up and outward on the drive bracket to disengage the notches To reassemble seat the bottom of the drive bracket so the notches are engaged at the bottom of the drive back plate Push the top of...

Страница 16: ...assembly Reattach the regenerant piston if needed to the main piston Do not lubricate the piston rod main piston or regenerant piston Lubricant will adversely affect the red or clear lip seals Reinser...

Страница 17: ...plugs If no water meter wire is visible then a plug is installed not a water meter The water meter wire does not need to be removed from the PC board if the water meter is only being inspected and cl...

Страница 18: ...Front Cover ASY 1 2 KC12V3107 01 W100SM Motor 1 3 KC12F3106 01 W100SM Drive Bracket 1 Spring Clip 4 KC12V3108 W100SM PC Board 1 5 KC12V3110 W100SM Drive Gear 12x36 3 6 KC12V3109 W100SM Drive Gear Cove...

Страница 19: ...ng No Order No Description Qty 1 KC12V3176 Injector Cap 1 2 KC12V3152 O ring 135 1 3 KC12V3177 Injector Screen 1 4 KC12V3010 12 W100SM Injector ASY Z Plug 1 5 KC12V3010 10 W100SM Injector ASY D Red 1...

Страница 20: ...etainer ASY 1 8 KC12V3182 W100SM RFC 1 Assembly includes WS1 RFC This part is required for backwash only systems DRAIN LINE 3 4 Drawing No Order No Description Qty 1 KC12H4615 Elbow Locking Clip 1 2 K...

Страница 21: ...0SM Split Ring 2 3 KC12V3105 O ring 215 2 4 KC12V3149 W100SM Fitting 1 PVC Male NPT Elbow 2 Drawing No Order No Description Qty 1 KC12V3151 W100SM Nut 1 Quick Connect 2 2 KC12V3150 W100SM Split Ring 2...

Страница 22: ...10 KC12V3156 O ring 214 2 Not Shown Order No KC12 V3191 01 Description WS100sm Bypass Vertical Adapter Assembly Order No Description Qty KC12V3151 W100SM Nut 1 Quick Connect 1 KC12V3150 W100SM Split R...

Страница 23: ...23 DRAWING AND PART NUMBERS flow diagram service flow diagram rinse flow diagram backwash flow diagram fill flow diagram downflow brine...

Страница 24: ...nk is required F Leak at distributor tube F Make sure distributor tube is not cracked Check O Ring and tube pilot G Internal valve leaking G Replace seals and spacers and or piston 4 Unit used too muc...

Страница 25: ...rol leak E Change seals spacers and piston assembly 10 Control cycles continuously A Broken or shorted switch A Determine if switch or timer is faulty and replace it or replace complete power head 11...

Страница 26: ...source Jack black wire and plug back in to reset control valve b Foreign matter is lodged in control b Check piston and spacer stack valve assembly for foreign matter c High drive forces on piston c...

Страница 27: ...ve gear or drive cap assembly d Defective PC board d Replace PC board a By pass valve in bypass position a Put control valve in service position b Meter connection disconnected b Connect meter to PC b...

Страница 28: ...Manufactured by Watts Water Quality Conditioning Products 13700 Highway 90 W San Antonio TX USA FORM 0500 200 P N XOSW100SM DISTRIBUTED BY...

Отзывы: