6

Water quality

Water quality from an RO system is normally
determined with a TDS Meter, which measures 

total

dissolved solids

in water, measuring conductivity.

The results are normally measured in parts per
million or milligrams per liter. Fewer dissolved
solids results in higher quality water.

RO membranes are rated by the amount of
dissolved solids they reject, expressed as "rejection"
percentage".   For example if feed water contains

100 ppm of dissolved solids and the product water
after the membrane has 10 ppm of dissolved solids
the rejection rate is 90%. The formula is as follows:

Percent rejection =

Feed water TDS– Product water TDS X 100%

Feed water TDS

Water production

Product water rate

Usable water production from an RO system is
designated

product water rate,

produced on a daily

basis. The rate is normally described in gallons per
day (gpd) or milliliters per minute (ml/min.).

Reject water rate

The flow of water to drain is designated as 

reject

water rate,

as measured in gallons per day (gpd) or

milliliters per minute (ml/min.).

Using a graduated cylinder the formulas are:

Milliliters per minute X 0.38 = gallons per day
Ounces per minute X 11.2 = gallons per day

Reject ratio

The

reject ratio

is the amount of water produced

compared to the amount of   water flowing to drain.
The formula is as follows:

Reject rate

Reject ratio =

Product rate

Percent recovery

The

percent recovery

is another way to measure

the amount of water produced compared to the
amount of water which is actually used.

The formula to determined

percent recovery

is as

follows:

Product water rate X 100%

Percent recovery =

Feed water rate

Note: Product water rate is the sum of the feed
water flow rate and reject water flow rate.

Example:

Product water rate =10 gpd
Reject water rate = 40 gpd
Feed water = 10 gpd + 40 gpd or 50 gpd

Percent recovery = 20%

Water pressure and temperature

Product water quality and production of RO
systems

is

dependent

on

pressure

and

temperature. Typically, RO membranes are treated
at standard conditions of 77

˚

 F (25

˚

 C) and 60 psi

(4 bar) discharging to atm osphere. In general, the
higher the pressure differential and temperature,

increased quality and quantity of water is produced.

These factors should be considered when sizing
RO systems for a particular application.

John Guest

®

brand fittings

Many RO systems utilize John Guest brand fittings.
These user - friendly fittings

provide superior

performance and may be provided with this system.
Proper use of these 

push-in

  fittings is shown below

Along with these fittings, all tubing selected must be
of high quality and must be cut with a plastic tube
cutter or sharp razor with a clean, square cut.

Should a leak occur at a fitting, the cause is
generally defective tubing. To fix a leak,   relieve
pressure, release tubing, cut off at least 1/4" from
the end (square cut), reattach the tubing and
confirm the connection is leak free. Each time a
new connection is made, it is advisable to cut off
1/4" from the end of the tubing using these fittings.

Conventional  compression fittings

If John Guest fittings are not used, it is essential to
install

inserts

at the ends of all tube connections

when conventional fittings are used.

To attach Tubing

Cut the tube square and push into the tube stop. For 
metal tube, remove burrs and chamfer tube end to
prevent the "O" ring seal from being damaged. For soft 
or thin walled plastic tubing we recommend the use 
of a tube insert.

Pull the tube to check that it is secure. It is good
pratice to check the system before use.