APPENDIX A:
TECHNICAL SPECIFICATIONS
A-1
APPENDIX A: TECHNICAL SPECIFICATIONS
02S
04S
07S
15S
22S
04T
07T
15T
22T
0.2
0.4
0.75
01.Mai 02.Feb
0.4
0.75
01.Mai 02.Feb
1/4
1/2
1
2
3
1/2
1
2
3
0.6
1.0
1.6
2.9
4.2
1.2
2.0
3.3
4.4
1.6
2.5
4.2
7.5
11.0
1.5
2.5
4.2
5.5
Recommended
50 Hz
72K4
72N4
81N4
91L4 101L4 72N4
81N4
91L4
101L4
WATT motor type *)
87/100 Hz
72K4
72N4
81N4
91S4
4.9
6.5
9.7
15.7
24
1.7
2.9
5.1
6.9
Keypad
External
Signal
Keypad
External
Signal
Con-
vection
W
85
85
85
100
100
85
85
100
100
H
148
148
148
186
186
148
148
186
186
D
126
126
126
129.3 129.3
124
126
129
129
L2500-00xyz_W1
size
A
B
B
E
E
C
D
F
F
Weight
kg
1.3
1.5
1.5
2.2
2.5
1.5
1.5
2
2.2
EMC-conformity
cable length (2nd envir.)
m
65
65
65
65
70
50
50
50
50
cable length (1st envir.)
m
20
20
20
20
25
20
20
20
20
Forced Air Cooling
Vibration
9.80665m/s
2
(1G) less than 20Hz, 5.88m/s
2
(0.6G) at 20 to 50Hz
Storage/Transportation Temp.
-20
°
C to 60
°
C
Ambient Humidity
Below 90% RH (non-condensing)
Cooling Methods
Env
iroment
Installation Location
Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust
Pollution Degree
2
Ambient Temperature
-10
°
C to 40
°
C (Non-Condensing and not frozen)
Other Function
PID-control, AVR, S-Curve, Over-Voltage, Over-Current Stall Prevention,
Fault Records, Adjustable Carrier Frequency, DC Braking, Braking
Chopper, Momentary Power Loss restart, Frequency Limits, Parameter
Lock/Reset, PLC-function, Reverse Inhibition, etc.
Protection
Self-testing, Over Voltage, Over Current, Under Voltage, Overload,
Overheating, External Fault, Electronic thermal, Ground Fault, etc.
Multi-step selection 0 to7, Jog, accel/decel inhibit, first/second
accel/decel switch, counter, PLC operation, external Base Block (NC,
NO), etc.
Multi-Function Output Indication
AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault
Indication, Local/Remote indication, PLC Operation indication, etc.
Analog Output Signal
Analog frequency/current signal output.
Stall Prevention Level
20 to 200%, Setting of Rated Current
Operating Charac
teris
tic
s
Frequency Setting
Setting by
! #
or Potentiometer
Potentiometer - 5k
Ω
/0.5W, DC 0 to +10V or 0 to +5V (Input impedance
47k
Ω
), RS-485 interface, 4 to 20mA (Input impedance 250
Ω
); Multi-
Function Inputs 1 to 6 (8 steps, Jog, up/down)
Operation Setting Signal
Setting by RUN, STOP
DI1 to DI6 can be combined to offer various modes of operation,
RS-485 serial interface (MODBUS)
Multi-Function Input Signal
150% of rated current for 1 minute (every 10 min.)
Accel/Decel Time
0.1to 600 second (2 Independent settings for Accel/Decel Time)
V/F Pattern
V/F pattern adjustable
Voltage/Freq. Tolerance
Voltage:
±
10%, Frequency:
±
5%
Control
Charac
teris
tic
s
Control System
SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 3k-10kHz)
Output Frequency Resolution
0.1Hz
Torque Characteristics
Including auto-torque boost, auto-slip compensation;
starting torque up to 150% at 5Hz
Overload Endurance
Proportional to Input Voltage: 3 ~ 0 - 200...240V (380...480V)
Rated Frequency (Hz)
1.0 to 400 Hz
Input
Rating
Rated Input Current (A)
Single-phase
3-phase
Rated Voltage/Frequency
200/208/220/240VAC 50/60Hz
380/400/415/480VAC 50/60Hz
Max. Applicable Motor Output (kW)
Output Rating
Rated Output Capacity (kVA)
Rated Output Current (A)
Maximum Output Voltage (V)
Max. Applicable Motor Output (HP)
Voltage Class
230V Class
400/460V Class
ECO-line L2500-00_ _ _xW1
Dimensions (mm)
internal EMC-filter according to
EN61800-3 amendment A11
optional external EMC-filter
according to EN61800-3
amendment A11
EMC