FREQUENCY INVERTER
Series L2500
MANUAL
Страница 1: ...FREQUENCY INVERTER Series L2500 MANUAL...
Страница 2: ...nsation WATT DRIVE NORD GmbH Eickelstra e 4 D 59759 Arnsberg Germany EUROPE Tel 49 2932 96 81 0 Fax 49 2932 96 81 81 e mail info wattdrive de Web www wattdrive de WATT DRIVE S D GmbH Walkenm hleweg 49...
Страница 3: ...justed and serviced only by qualified electrical maintenace personel familiar with the construction and operation of the equipment and the hazards involved Failure to observe this precaution could res...
Страница 4: ...ply with the laws of the country where the AC drive is to be installed Refer to Basic Wiring Diagram Chapter 3 CAUTION The final enclosures of the AC drive must comply with EN50178 Live parts shall be...
Страница 5: ...installation Chapter 3 wiring Chapter 4 digital keypad operation Chapter 5 parameters Chapter 6 maintenance and inspections Chapter 7 troubleshooting and fault information Chapter 8 summary of paramet...
Страница 6: ...iving Check to make sure that the package includes an AC drive the User Manual and rubber bushings Inspect the unit to insure it was not damaged during shipment Make sure that the part number indicate...
Страница 7: ...ons Operation Air Temperature 10 C to 40 C 14 F to 104 F Relative Humidity 0 to 90 no condensation allowed Atmosphere pressure 86 kPa 0 86 bar to 106 kPa 1 06 bar Installation Site Altitude below 1000...
Страница 8: ...drive vertically and do not restrict the air flow to the heat sink fins Non Ventilated Enclosures When selecting non ventilated enclosures for the L2500 series please consider the following minimum d...
Страница 9: ...ers Laboratories cUL listed and therefore comply with the requirements of the National Electrical Code NEC and the Canadian Electrical Code CEC WATT Drive GmbH also declare the conformity of all L2500...
Страница 10: ......
Страница 11: ...as to be kept to less than 50m When using motor cables longer than 50m L2500 motor filters should be installed Directions for installing filters can be found in the L2500 installation manual Seperate...
Страница 12: ...ld and PE potential you can realise with a metal PG screw connection or a metallic mounting clip Use only copper mesh cable CY with 85 coverage The shielding should not be interrupted at any point in...
Страница 13: ...ion The filter must be solidly and permanently connected with the ground potential so as to preclude the danger of electric shock upon touching the filter if a fault occurs You can achieve this by con...
Страница 14: ...3 1 Basic Wiring Diagram Users must connect wiring according to the following circuit diagram shown below 4 7k 47K 4 7k 4 7k 4 7k 4 7k 4 7k Please refer to 3 4 for detail NPN J2 PNP DI1 DI2 DI3 DI4 DI...
Страница 15: ...resistance less than 100 RA RB RC Please refer to 3 4 for detail Multi function Photocoupler output below 48VDC 50mA Factory default Indicates during operation AFO GND Potentiometer 1K DC 0 10V Analo...
Страница 16: ...ro phase Reactor Ferrite Core Common Choke Optional Zero phase reactors are used to reduce radio noise specify when the audio equipments installed near the inverter Good effective for noise reduction...
Страница 17: ...1 DC Reactor Braking Resitor Ground 2 Terminal Explanations Terminal Symbol Explanation of Terminal Function R L1 S L2 T L3 AC line input terminals three phase L L1 N L2 AC line input terminals singl...
Страница 18: ...D Analog voltage current freq command 0 to 10 V Max Output Frequency Input or 4 to 20mA Max Output Frequency Input AF0 GND Analog frequency current meter 0 to 10 V Max output Frequency Output DI1 GND...
Страница 19: ...rds and keep them as short as possible 7 Multiple L2500 units can be installed in one location All the units should be grounded directly to a common ground terminal The L2500 ground terminals may also...
Страница 20: ...Filter Inductance Capacitance or R C Filter Resistance Capacitance 16 When using a GFCI Ground Fault Circuit Interrupt select current sensor with not less than 200mA and not less than 0 1 second dete...
Страница 21: ...ters and enter information UP and DOWN Key Sets the parameter number or changes the numerical data such as the freq reference MODE Mode By pressing the mode key repetitively the display will show stat...
Страница 22: ...he counter value C The internal PLC process step currently being performed The DC BUS voltage The output voltage The specified parameter group The specified parameter The actual value stored within th...
Страница 23: ...n REV LED lights during reverse operation 1 Description of LED functions of RUN and STOP Output frequency of the AC motor drive KEY Frequency command KEY KEY RUN Indication STOP Indication Light Flash...
Страница 24: ...ay parameter number REV state can t attain if reverse is inhibited Communication error only appears when communication error happens Set parameter group Set parameter number Store data Set parameter d...
Страница 25: ...on are listed right here below The complete list of parameters for preparing the inverter for your special applications requirements can be found in chapter 8 of this manual or as detailed description...
Страница 26: ...f power loss and it can do analog overlap plus d4 Master Frequency operated by RS 485 serial communication interface record the frequency of power loss and it can do analog overlap plus d5 Master Freq...
Страница 27: ...d Acc Dec d12 First or Second Acceleration deceleration Time Selection d7 4 07 Multi Function Digital Input Terminal 4 DI5 d13 Base Block B B N O d14 Base Block B B N C d15 Increase Master Frequency d...
Страница 28: ...ther the cooling system is operating as expected 4 Whether any irregular vibration or sound occurred during the operation 5 Whether the motors are overheated during the operation 6 Always check the in...
Страница 29: ...xcessive loading conditions at the motor 5 If there are any abnormal conditions when operating the AC drive after short circuit being removed it should be sent back to manufacturer The AC drive detect...
Страница 30: ...boost too high 3 Acceleration time too short 4 AC drive output capacity is too small 1 Check for possible poor insulation at the output line 2 Decrease the torque boost setting in Pr 7 02 3 Increase t...
Страница 31: ...factory Auto accel decel failure Don t use the function of auto acceleration deceleration Ground fault The AC drive output is abnormal When the output terminal is grounded short circuit current is 50...
Страница 32: ......
Страница 33: ...se d0 0 03 Start up Display Selection d0 F setting frequency d1 H actual output frequency d2 user defined unit d3 A output current d1 0 04 Content of Multi Function Display d0 Display User Defined Uni...
Страница 34: ...leration Time 1 Tdec1 d0 1 to d600 sec 0Hz to Pr 1 00 d10 0 1 11 Acceleration Time 2 d0 1 to d600 sec 0Hz to Pr 1 00 d10 0 1 12 Deceleration Time 2 d0 1 to d600 sec 0Hz to Pr 1 00 d10 0 1 13 Jog Accel...
Страница 35: ...RS 485 serial communication interface record the frequency of power loss and it can do analog overlap plus d5 Master Frequency operated by RS 485 serial communication interface won t record the frequ...
Страница 36: ...to d19 d0 3 04 Preliminary Count Value d0 to d999 d0 3 05 Multi Function Digital Output1 Photocoupler Output d1 3 06 Multi Function Digital Output2 Relay Output d0 Not Used d1 AC Drive Operational d2...
Страница 37: ...ation d11 Acceleration deceleration Speed Inhibit Suspend Acc Dec d12 First or Second Acceleration deceleration Time Selection d7 4 07 Multi Function Digital Input Terminal 4 DI5 d13 Base Block B B N...
Страница 38: ...z d0 0 5 06 7th Step Speed Freq d0 0 to d400 Hz d0 0 5 07 PLC Mode d0 Disable PLC Operation d1 Execute one program cycle d2 Continuously execute program cycles d3 Execute one program cycle step by ste...
Страница 39: ...led during running and halted after Over Torque detection d0 6 04 Over Torque Detection Level d30 to d200 d150 6 05 Time setting for Over torque Detection d0 1 to d10 0 Sec d0 1 6 06 Electronic Therma...
Страница 40: ...th Master Frequency 8 04 Momentary Power Loss Operation Selection d2 Continues after Momentary Power Loss speed search starts with Minimum Output Frequency d0 8 05 Maximum Allowable Power Loss Time d0...
Страница 41: ...lanation Settings Factory Setting Actual Setting A 00 PID Feedback Terminal Selection d0 Disable PID function d1 Negative feedback 0 10V AVI d2 Negative feedback 4 20mA ACI d3 Positive feedback 0 10V...
Страница 42: ...cond accel decel switch counter PLC operation external Base Block NC NO etc Multi Function Output Indication AC Drive Operating Frequency Attained Non zero Base Block Fault Indication Local Remote ind...
Страница 43: ...e are permitted Line Fuse Model I input A I output A I A 1 I A 2 UDGL2500 0002SAW1 4 9 1 6 15 6 UDGL2500 0004SBW1 6 5 2 5 20 10 UDGL2500 0007SBW1 9 7 4 2 30 16 UDGL2500 0015SEW1 15 7 7 5 50 20 UDGL250...
Страница 44: ...ase select the factory default resistance value Watt and the frequency value ED 2 If damage resulted in the drive or other equipments due to the fact that the braking resistors and the braking modules...
Страница 45: ...B B 3 Dimensions mm inch 60 2 36 200 7 87 85 3 35 200 7 87 50 1 97 27 1 06 24 0 94 15 0 52 4 5 0 18 213 8 39 UDZNFL 007T...
Страница 46: ...APPENDIX B ACCESSORIES B 4 27 1 06 50 1 97 228 8 98 15 0 59 24 0 94 100 3 94 228 8 98 74 2 91 5 5 0 22 241 9 49 UDZNFL 022T...
Страница 47: ...A A1 C D a d e c b B1 B ACHTUNG HOCHSPANNUNG VOR DEM FFNEN DES UMRICHTERS MINDESTENS 5 MINUTEN WARTEN BETRIEBSANLEITUNG BEACHTEN WARNING HIGH VOLTAGE WAIT AT LEAST 5 MINUTES BEFORE OPENING FOLLOW USE...
Страница 48: ...173 6 82 129 3 5 09 5 4 0 21 5 5 0 22 1 0 04 9 5 0 38 5 5 0 22 6 5 0 26 UDGL2500 0022SEW1 100 3 94 86 5 3 41 186 7 33 173 6 82 129 3 5 09 5 4 0 21 5 5 0 22 1 0 04 9 5 0 38 5 5 0 22 6 5 0 26 UDGL2500 0...