3
12. Electrical connection between rail segments shall be disconnected prior to removal of a mechanical
connection.
13. The system may be supplied by a three phase power system with four individual circuits rated at 20
amps/120 volts max-imum, or as permitted by local code.
14. No more than 12 duplex receptacles shall be supplied by one circuit. (12 segments Two Duplex, 6 segments Four
15. For commercial use only.
NOTE - Installation must be in accordance with the National Electrical Code and local codes. Electrically interconnected
tables need to be mechanically connected.
General Rail Assembly Notes
It is recommended to perform as much of the rail assembly upside-down, keeping in mind how many installers are
available to flip the run right-side up once assembled.
If 1 - 2 installers: flip the first rail segment upside down and complete steps 1 & 2. Then flip the
rail right side up and continue with instructions, adding one segment at a time for step 3.
If 3+ installers: complete steps 1-4 with the rail flipped upside down. Once complete, flip right
side up. The length of run will determine how many installers are needed to perform the flip.
If Using Optional Utility Power -
1. The electrical desk plug must be plugged into the utility power when present.
2. This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug
illustrated in sketch A (see Figure 77.1). Make sure that the product is connected to an outlet having the
same configuration as the plug. No adapter should be used with this product.
Save These Instructions
OPERATING INSTRUCTIONS – Please refer to the provided Installation Instructions and User Guide.
POLARIZED PLUG INSTRUCTIONS – To reduce the risk of electric shock, this furnishing has a polarized plug (one
blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the out-
let, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the
plug in any way.
SERVICING OF DOUBLE-INSULATED PRODUCTS – In a double-insulated product, two systems of insulation are
provided instead of grounding. No grounding means is provided on a double-insulated product, nor is a means for
grounding to be added to the product. Servicing a double-insulated product requires extreme care and knowledge of
the system, and is to be done only by qualified service personnel. Replacement parts for a double-insulated product
must be identical to the parts they replace. A double-insulated product is marked with the words “DOUBLE
INSULATION”, “DOUBLE INSULATED”, or .
This product is for use on a nominal 120-V circuit. Make sure that the product is connected to an outlet having the
same configuration as the plug. No adapter should be used with this product.