Содержание 730 U

Страница 1: ...eturning pumps 8 5 Peristaltic pumps an overview 8 6 Warranty 9 7 Safety notes 10 8 Pump specifications 13 8 1 Specification ratings 13 8 2 Weights 13 8 3 Pumphead options 14 9 Good pump installation practice 15 9 1 General recommendations 15 9 2 Dos and don ts 16 10 Pump operation 17 10 1 Keypad Layout and Key IDs 17 10 2 Starting and stopping 18 10 3 Using up and down keys 18 10 4 Maximum speed ...

Страница 2: ... Selecting the display language 47 14 2 First time start up defaults 49 15 Switching the pump on in subsequent power cycles 51 16 Mode menu 52 17 Manual 53 17 1 START 53 17 2 STOP 54 17 3 INCREASING AND DECREASING FLOW RATE 54 17 4 MAX FUNCTION Manual mode only 55 18 Flow calibration 56 18 1 Setting the flow calibration 56 19 Analog mode 59 19 1 Analog calibration 60 19 2 Calibrate Input 1 61 19 3...

Страница 3: ...es 107 22 3 Technical support 108 23 Drive maintenance 109 24 Drive spares 110 25 Pumphead replacement 111 25 1 Pumphead replacement 111 26 Tube replacement 113 26 1 Continuous tubing 113 26 2 Tube elements 113 27 Ordering information 115 27 1 Pump part numbers 115 27 2 Tubing and element part numbers 116 27 3 Pumphead spares 118 28 Performance data 122 28 1 720R 720RE 720R RX and 720RE REX perfor...

Страница 4: ...Original instructions The original instructions for this manual have been written in English Other language versions of this manual are a translation of the original instructions 4 m 730un en 08 1 ...

Страница 5: ... Machinery Directive 2006 42 EC EMC Directive 2014 30 EC ROHS Directive 2015 863 6 Harmonised standards used BS EN61010 1 2010 third edition Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements EN61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements BS EN 60529 1992 A2...

Страница 6: ...uality Management System ISO 9001 and the technical documentation is compiled in accordance with Annex VII B of the Directive We undertake to transmit in response to a reasoned request by the appropriate national authorities relevant information on the partly completed machinery identified above The method of transmission shall be by mail or email The pump head is incomplete and must not be put in...

Страница 7: ...omponents supplied 730 Components l 730 pump drive unit fitted with 720R or other pumphead if specified as a pump l The designated power cable attached to the pump drive unit l A 730N module providing pump ingress protection to IP66 NEMA 4X l Note the module is attached for transit but must be removed to allow wiring up voltage selection and fuse inspection and then re affixed before the pump is o...

Страница 8: ...er advances along the tube the seal also advances After the roller has passed the tube returns to its original shape creating a partial vacuum which is filled by fluid drawn from the inlet port Before the roller reaches the end of the track a second roller compresses the tube at the start of the track isolating a packet of fluid between the compression points As the first roller leaves the track t...

Страница 9: ...warranty does not obligate Watson Marlow to bear any costs of removal installation transportation or other charges which may arise in connection with a warranty claim Watson Marlow shall not be responsible for shipping damage of returned items Conditions o Products must be returned by pre arrangement to Watson Marlow or a Watson Marlow approved service centre o All repairs or modifications must ha...

Страница 10: ... regulations and guidance This symbol used on the pump and in the manual means An appropriate safety instruction should be followed or caution to a potential hazard exists This symbol used on the pump and in the manual means Do not allow fingers to contact moving parts This symbol used on the pump and in the manual means Caution hot surface This symbol used on the pump and in the manual means Caut...

Страница 11: ... are no user serviceable fuses or parts inside this pump Note the mains power supply cable is supplied hardwired into the pump and is not customer replaceable Observe voltage selector switch setting for your region IP66 pumps are supplied with a mains plug The gland at the NEMA Module end of the cable is IP66 rated The mains plug at the opposite end of the cable is NOT IP66 rated It is the user s ...

Страница 12: ...ous settings Do not use auto restart for more than 12 times in 24 hours We recommend remote control where a high number of starts is required If the pump is configured to network mode or analog mode it will respond to remote commands at any time including immediately after power on The Symbol is shown on the screen to warn users that the pump may operate without any manual intervention e g a remot...

Страница 13: ...T2 5AH250V 5x20mm Installation category overvoltage category II Pollution degree 2 IP 730 IP66 to BS EN 60529 Equivalent to NEMA 4X to NEMA 250 indoor use protect from prolonged UV exposure dB rating 730 85dB A 1m Control ratio 730 0 1 360rpm 3600 1 Maximum speed 730 360rpm 8 2 Weights 730 Drive only 720R 720RE 720RX 720REX IP66 NEMA 4X 18 5kg 40lb 13oz 25kg 55lb 2oz 31 5kg 69lb 7oz Some pumps wei...

Страница 14: ...8 3 Pumphead options 730 pump range 720R 720R RX 720RE 720RE REX 14 m 730un en 08 1 ...

Страница 15: ...t the direction of rotor rotation is clockwise or counter clockwise whichever is convenient Please note however that for some pumpheads the tube life will be greater if the rotor rotates clockwise and that performance against pressure will be maximised if the rotor rotates counter clockwise To achieve pressure in some pumpheads the pump must rotate counter clockwise Optimum tube life Maximum press...

Страница 16: ...pipe runs with a bore several times larger than the pump tube l Do site the pump at or just below the level of the fluid to be pumped if possible This will ensure flooded suction and maximum pumping efficiency l Do run at slow speed when pumping viscous fluids Flooded suction will enhance pumping performance particularly for materials of a viscous nature l Do recalibrate after changing tubing flui...

Страница 17: ...nown operating mode FUNCTION keys FUNCTION keys when pressed will perform the function displayed on the screen directly above the relevant function key and keys These keys are used to change the programmable values within the pump These keys are also used to move the selection bar up and down in the menus MODE key To change modes or mode settings press the MODE key The MODE key can be pressed at a...

Страница 18: ...10 2 Starting and stopping 10 3 Using up and down keys 10 4 Maximum speed 10 5 Change rotation direction 18 m 730un en 08 1 ...

Страница 19: ...the switch plate at the rear of the pump protected from water by the N module The module must be removed to allow access to the switch plate Do not switch the pump on unless you have checked that it is set to suit your power supply by removing the module and inspecting the switch and then refitting the module 1 2 3 4 We recommend using a commercially available supply voltage surge suppression wher...

Страница 20: ...n to 13 32in two M20 ports are provided together with glands to seal circular cross section cables ranging in diameter from 10mm to 14mm 13 32in to 9 16in rated for IP66 minimum Four adaptors are also supplied two M16 male to 3 8in NPT female and two M20 male to 1 2in NPT female These can be used to fit flexible conduit systems where NPT threads are required 11 3 Earth screening of control cables ...

Страница 21: ...hat proper connections are achieved between the pump and suction and discharge piping o Ensure proper connection has been made to a suitable power supply o Ensure that the recommendations in the section Good pump installation practice on page 15 are followed m 730un en 08 1 21 ...

Страница 22: ...ductive back shell This will be connected to pump mains EARTH via the D connector body Mains Earth is also available on pin 1 Upper D and pin 13 Lower D Functional earth Leak Auto man Reserved do not use Reserved do not use Signal ground 0V VAUX 22 5V Commoning terminals used for voltage supply for logic outputs Signal ground 0V Logic output 1 Logic output 2 Logic output 4 Logic output 3 Upper D c...

Страница 23: ... OPEN COLLECTOR TO GROUND INPUT OUTPUT MANUAL KEYPAD CONTROL ANALOGUE 4 20mA 0 10V CONTROL START DOSE ON RISING EDGE DRY NO LEAK WET LEAK DETECTED KEYPAD DIRECTION CHANGE REMOTE DIRECTION CHANGE ALARM PULL UP RESISTOR COMMON Wiring the upper D connector Signal Name Input or output Configurable Signal response LEAK LEAK LEAK Yes Leak high Leak low m 730un en 08 1 23 ...

Страница 24: ...Signal Name Input or output Configurable Signal response AUTO MAN AUTOMAN AUTOMAN No LOGIC OUT 1 LOGIC OUT 1 Yes Output 1 LOGIC OUT 2 LOGIC OUT 2 Yes Output 2 24 m 730un en 08 1 ...

Страница 25: ... or output Configurable Signal response LOGIC OUT 3 LOGIC OUT 3 Yes Output 3 LOGIC OUT 4 logic_out4 pdf LOGIC OUT 4 Yes Output 4 COMMON Commoning terminals used for voltage supply for logic outputs No m 730un en 08 1 25 ...

Страница 26: ...Wiring the lower D connector Function Input or output Configurable Signal response TACHO FREQUENCY TACHO F Hz No TACHO TACHO mA No 4 20mA TACHO 0 10V No 0 10V 26 m 730un en 08 1 ...

Страница 27: ...Function Input or output Configurable Signal response TTL 1 TTL OUT 1 Yes Output 1 TTL 2 TTL OUT 2 Yes Output 2 DIRECTION DIRECTION DIRECTION No m 730un en 08 1 27 ...

Страница 28: ...Function Input or output Configurable Signal response START STOP START STOP START STOP Yes Stop high Stop low DIRECTION ENABLE DIRECTION ENABLE DIRECTION ENABLE No 28 m 730un en 08 1 ...

Страница 29: ...Function Input or output Configurable Signal response DOSE DOSE DOSE No ANALOG 1 ANALOG 1 0V 0V Yes Either 0 10V or 4 20mA ANALOGUE 1 10V REF Yes 0 10V m 730un en 08 1 29 ...

Страница 30: ...s VAUX Upper 21 Nom 22V 18 35V unregulated 10mA Nom 100mA fused 13 5 N Modules Standard and SCADA The recommended cable and cable glands must be used for the IP66 NEMA 4X version of the pump otherwise ingress protection may be impaired Ensure that the module cover is correctly secured at all times by all screws supplied Failure to do so may compromise the IP66 NEMA 4X protection Ensure that unused...

Страница 31: ... PCB attached to the pump rear Disconnect the Module ribbon from the pump by use of the ribbon eject levers on the connector board Recommended control cable metric 0 14sq mm 2 5sq mm solid and 0 14sq mm 1 5sq mm stranded USA 26AWG 14AWG solid and 26AWG 16AWG stranded Cable circular Max min outside diameter to ensure a seal when passed through the standard gland 9 5mm 5mm The cable section must be ...

Страница 32: ...0V CONTROL EXTERNAL VOLTAGE INPUT DRY NO LEAK WET LEAK DETECTED KEYPAD DIRECTION CHANGE REMOTE DIRECTION CHANGE START DOSE ON RISING EDGE Connector No Function Input or output Configurable Signal response J1 AUTO MAN AUTO MAN No J2 DIRECTION CW CCW DIRECTION No Standard N Module Input output Connectors 32 m 730un en 08 1 ...

Страница 33: ...ector No Function Input or output Configurable Signal response J3 DOSE DOSE No J4 STOP HIGH RUN STOP STOP LOW RUN STOP RUN STOP Yes Stop high Stop low J5 ANALOGUE 1 Yes J6 DIRECTION EN No m 730un en 08 1 33 ...

Страница 34: ...e Signal response J7 REMOTE POT No 10V 10mA Max J8 ANALOGUE 2 Yes J9 LEAK DETECT HIGH LEAK DETECT LEAK DETECT LOW LEAK DETECT LEAK DETECT Yes Leak high Leak low J10 R S 4 8 5 0 V A B J 1 0 J11 TACHO O P No Hz 5V TTL V 0 10V I 4 20mA 34 m 730un en 08 1 ...

Страница 35: ...3 COMMONING J14 15 16 17 RELAY 1 4 Yes LOW N C HIGH N O 24V DC MAX SW1 SW1 Switches in or out a 124R termination resistor May be required for long cable lengths SW2 SW2 Switches in or out a filter capacitor for optional use when internal terminal is selected May be of use if data errors occur with long lines m 730un en 08 1 35 ...

Страница 36: ...mm solid and 0 14sq mm 1 5sq mm stranded USA 26AWG 14AWG solid and 26AWG 16AWG stranded Cable circular Max min outside diameter to ensure a seal when passed through the standard gland 9 5mm 5mm The cable section must be circular to ensure a seal Never apply mains power above 130V AC to the terminals within the SCADA module Apply the correct signals to the terminals shown Limit signals to the maxim...

Страница 37: ...AC ALTERNATING CURRENT INPUT DRY NO LEAK WET LEAK DETECTED KEYPAD DIRECTION CHANGE REMOTE DIRECTION CHANGE START DOSE ON RISING EDGE Connector No Function Input or Output Configurable Signal Response J1 AUTO MAN No J2 DIRECTION No J3 DOSE No J4 RUN STOP Yes Stop high Stop low SCADA N Module Input output Connectors m 730un en 08 1 37 ...

Страница 38: ...put or Output Configurable Signal Response J5 ANALOGUE 1 Yes J6 DIRECTION EN No J7 REMOTE POT No 10V 10mA Max J8 ANALOGUE 2 Yes J9 LEAK DETECT LEAK DETECT Yes Leak high Leak low J10 TACHO O P No 0 10V 4 20mA 38 m 730un en 08 1 ...

Страница 39: ...ds it can receive and the diagnostic information it can pass to the PROFIBUS master on interrogation Note The data flow to and from the pump may need to be byte reversed due to the differences of handling between suppliers of master devices The GSD file file name WAMA0F70 GSD can be found at our website wmftg com User parameter data The user parameter data is set by entering values into the Ext_Us...

Страница 40: ...seed Low byte Fieldbus Max speed high byte Fieldbus Max speed low byte Fail safe Fail safe speed high byte Fail safe speed low byte 0x03 0x80 0x00 0x00 0x00 0x00 0x00 0x00 0x00 730 with 720R head 0x03 0x80 0x00 0x00 0x05 0xDC 0x00 0x00 0x00 730 with 720R head with maximum speed set at 150RPM 0x03 0x80 0x01 0xF4 0x00 0x00 0x00 0x00 0x00 730 with 720R head with minimum speed set and 50RPM min speed ...

Страница 41: ... Control Word is enabled and they are not zero All values are 16 bit unsigned in 1 10th of RPM of the head speed Fail safe The fail safe user parameter is used to set the correct course of action to take in the event of a PROFIBUS communications failure The fail safe byte is configured as shown in the following table If no bits are set or an invalid bit pattern is set the default fail safe behavio...

Страница 42: ...n high byte Byte 6 Set flow calibration in 10µl per revolution low byte Control word Bit Description 0 Motor running 1 running 1 Direction 0 CW 1 CCW 2 Tacho reset 1 reset count 3 Reserved 4 Enable fieldbus min max speeds 1 enabled 5 Enable fieldbus flow calibration 1 enabled 6 15 Reserved Cyclic data read from pump to master 16 bit Byte 1 Status word high byte Byte 2 Status word low byte 16 bit B...

Страница 43: ...signed reports the speed that the pump is running in Profibus mode This is reported as an integer in units of rpm and will always be the same as the Profibus pumphead speed setpoint received by the pump Customers who wish to verify the flow rate of the pump should use the tacho counter which reports pumphead revolutions where 10 increments 1 revolution and the µl per revolutions value Byte 11 12 t...

Страница 44: ...8 bit Byte 7 Header byte 8 bit Byte 8 Pump model 8 bit Byte 9 Pump head 8 bit Byte 10 Tube size high byte 8 bit Byte 11 Tube size low byte 8 bit Byte 12 Min speed high byte 8 bit Byte 13 Min speed low byte 8 bit Byte 14 Max speed high byte 8 bit Byte 15 Max speed low byte 32 bit Byte 16 17 18 19 Software version Main CPU 32 bit Byte 20 21 22 23 Software version HMI CPU 32 bit Byte 24 25 26 27 Soft...

Страница 45: ...A8 Lower limit exceeded Setpoint out of range high 0xA7 Upper limit exceeded Fluid level alert 0xB3 Device related 0x15 Note Global error format 8 bit header 8 bit channel type and 8 bit error type Operating this pump under PROFIBUS control is beyond the scope of this instruction manual Consult your PROFIBUS network literature for further information Standard 9 way D PROFIBUS use Interfacing the p...

Страница 46: ...4 5 6 7 8 ON OFF PC PLC Avoid sharp bends in PROFIBUS communication cables Please follow PROFIBUS wiring standards 46 m 730un en 08 1 ...

Страница 47: ...irst time Power up the pump The pump displays the start up screen with the Watson Marlow Pumps logo for three seconds 14 1 Selecting the display language 1 Use the keys to select your chosen language and press SELECT m 730un en 08 1 47 ...

Страница 48: ...e will now be displayed on screen Choose CONFIRM to continue All text will now appear in your chosen language 3 Choose REJECT to return to the language choice screen This then proceeds to the home screen P 48 m 730un en 08 1 ...

Страница 49: ...ts rpm SG value 1 Keypad lock Disabled Auto restart OFF Analog signal type mA Analog scaling type mA Analog min current 5mA Analog max current 19mA Analog min flow rate rpm 0rpm Analog max flow rate rpm 360rpm Beeper ON Security code Not set MemoDose flow rate Mid flow rate of chosen pumphead MemoDose volume 100ml Pump number baud rate 9600 Stop bits 2 Remote start stop input High stop Leak detect...

Страница 50: ...ause the pump to start as soon as power is turned on Auto restart only affects operation of manual mode network mode and memodose mode If Auto restart is enabled the Symbol is shown on the screen to warn users that the pump may operate without any manual intervention pump resumes with previous settings Do not use auto restart for more than 12 times in 24 hours We recommend remote control where a h...

Страница 51: ...es Do not power up power down the pump more than 12 times in 24 hours whether manually or by means of the auto restart facility which only affects manual mode network mode and memodose operation We recommend remote control where a high frequency of power cycles is required If the Auto restart feature is enabled it may cause the pump to start as soon as power is turned on Auto restart only affects ...

Страница 52: ...ay the Change mode menu Use the and keys to scroll through the available modes Manual default Flow calibration Analog Memodose CANCEL Use SELECT to choose mode Use the right hand function key to alter mode settings 52 m 730un en 08 1 ...

Страница 53: ...es the pump will return to the last known settings from that operating mode when the power is re applied When the pump is running it displays an animated clockwise arrow In normal operation the direction of flow is into the bottom port of the pumphead and out of the top port If an exclamation mark is displayed it indicates that the pump could automatically restart at any time In manual mode networ...

Страница 54: ...y press will decrease flow rate by the least significant digit of the chosen flow rate unit o Repeat key presses as required to achieve the desired flow rate o Hold down the key for flow rate scrolling Increasing flow rate o A single key press will increase flow rate by the least significant digit of the chosen flow rate unit o Repeat key presses as required to achieve the desired flow rate o Hold...

Страница 55: ...ON Manual mode only o Press and hold the MAX key to run at maximum flow o Release the key to stop the pump o The volume dispensed and time elapsed are displayed while the MAX key is pressed and held m 730un en 08 1 55 ...

Страница 56: ...n This pump displays flow rate in ml min 18 1 Setting the flow calibration Using the keys scroll to Flow calibration and press CALIBRATE Using the keys enter the maximum flow rate limit and press ENTER 56 m 730un en 08 1 ...

Страница 57: ...Press START to begin pumping a volume of fluid for calibration Press STOP to stop pumping fluid for the calibration Use the keys to enter the actual volume of fluid pumped m 730un en 08 1 57 ...

Страница 58: ...To accept the new calibration press ACCEPT or RE CALIBRATE to repeat the procedure Press HOME or MODE to abort The pump is now calibrated 58 m 730un en 08 1 ...

Страница 59: ...an be proportional or inversely proportional to the analog input The default values stored in the pump are A 5mA 0 and B 19 8mA 100 Flow rate When the analog signal received is greater than the level defined by point A the run status output will be energised as the pump is running To select Analog mode select MODE Using the keys scroll to Analog and press SELECT The analog signal being received by...

Страница 60: ... values High and low signals must be within range If the signal sent is out of range you will not be able to set the signal input value and progress to the next step in the process Select MENU then select MODE menu Using the keys scroll to Analog and press CALIBRATE 60 m 730un en 08 1 ...

Страница 61: ...CT Select the input signal type using the keys and press SELECT The pump gives the option to enter the high and low mA or V signals manually or via the analog input Entering mA values is described here however the process for entering V signals is identical m 730un en 08 1 61 ...

Страница 62: ...ent values manually via the keypad or whether to apply the current signals electrically to the analog input 19 3 Setting a high signal Send the high signal input to the pump or enter the current value using the keys 62 m 730un en 08 1 ...

Страница 63: ...imits Press ACCEPT to accept the high signal input or CANCEL to return to the previous screen 19 4 Setting high flow calibration Using the keys scroll to the desired flow rate Select SET FLOW or press BACK to return to the previous screen m 730un en 08 1 63 ...

Страница 64: ...ow signal Send the low signal input to the pump or enter the current value using the keys If the range between the low and high signal is less than 1 5mA the following error message will be displayed 64 m 730un en 08 1 ...

Страница 65: ...l is within tolerance limits Press ACCEPT to accept the low signal input or CANCEL to return to the previous screen 19 6 Setting low flow calibration Using the keys scroll to the desired scale factor Select SET FLOW m 730un en 08 1 65 ...

Страница 66: ...This proceeds to the screen confirming calibration is complete Select ANALOG to start in analog mode or MANUAL to continue in manual mode 66 m 730un en 08 1 ...

Страница 67: ...ose a precise volume of fluid This can be achieved by dispensing a master dose or entering a dose volume manually using the keypad MemoDose can repeat this dose exactly or proportionately 20 1 To configure MemoDose o Select MODE o Using the keys scroll to MemoDose and press SETTINGS Note the pump must be stopped to enter MemoDose Settings 20 2 Set flow rate Using the keys scroll to Flow rate and p...

Страница 68: ...can be discarded and a new dose started when power is resumed From the MemoDose settings screen use the keys to scroll to Resume Interrupted Dose and press ENABLE The red cross will become a green tick to indicate that Resume interrupted dose is enabled If this function is enabled the ENABLE key becomes DISABLE If this is pressed interrupted doses will be discarded after a power cycle 68 m 730un e...

Страница 69: ...20 4 Master dose Using the keys scroll to Master dose and press SELECT The following screen is displayed press MANUAL to enter a dose via the keypad or DOSE to dispense a master dose m 730un en 08 1 69 ...

Страница 70: ...Dispensing a master dose Press START to begin dispensing the Master Dose Press STOP to finish dispensing the Master Dose 70 m 730un en 08 1 ...

Страница 71: ... screen Using the keys enter the required dose volume and press SELECT to record the master dose or CANCEL to return to MemoDose Settings Save dose volume Press SAVE to record the Master Dose or CANCEL to return to MemoDose settings m 730un en 08 1 71 ...

Страница 72: ...d press MEMODOSE to start in MemoDose Mode or BACK to return to MemoDose settings 20 5 Manual dosing From the MemoDose Home screen press START to deliver a dose The screen displays the dose flow rate and the dose remaining counting down from 100 to 0 72 m 730un en 08 1 ...

Страница 73: ...f the master dose Use the keys to alter the percentage The new dose size is displayed as a percentage on the home screen 107 0 If STOP is pressed during dosing the pump stops Pressing START will resume or discard the interrupted dose depending on the settings in Resume interrupted doses on page 68 m 730un en 08 1 73 ...

Страница 74: ...of the HOME screens or INFO screens This will display the main menu as shown below Use the keys to move the selection bar between the available options Press SELECT to choose an option Press EXIT to return to the screen from where the MENU was called 74 m 730un en 08 1 ...

Страница 75: ...m 730un en 08 1 75 ...

Страница 76: ...e Main menu Auto keypad lock Press ENABLE DISABLE to switch on off the Auto keypad lock When active the keypad will lock after 20 seconds of inactivity Once locked it will display the screen below when any key is pressed To unlock the keypad press the two UNLOCK keys together 76 m 730un en 08 1 ...

Страница 77: ...equired to disable PIN lock Setting Master PIN Setting the Master PIN protects all functionality The Master is able to selectively enable functionality for two additional operators These are defined as User 1 and User 2 They will be able to access this functionality by entering a PIN code assigned to them by the Master user To set the Master PIN scroll to Master level and press ENABLE To define a ...

Страница 78: ...Now press CONFIRM to check that the number entered is the PIN you require Press CHANGE to return to PIN entry 78 m 730un en 08 1 ...

Страница 79: ...tionality Press NEXT to selectively enable functionality access for User 1 and User 2 Configure User 1 security settings The PIN PROTECTION level screen will be displayed with User 1 highlighted press ENABLE to configure User 1 security settings or scroll to configure an alternative User m 730un en 08 1 79 ...

Страница 80: ...digit User 1 PIN use the keys to select each digit from 0 9 Once you have the required digit press the NEXT DIGIT key After selecting the fourth digit press ENTER Now press CONFIRM to verify that the number entered is the PIN you require Press CHANGE to return to PIN entry 80 m 730un en 08 1 ...

Страница 81: ...the functionality and press ENABLE User 1 PIN will allow access to only the enabled functionality to disable functionality highlight the enabled functionality and press DISABLE When all the required functionality has been enabled press FINISH m 730un en 08 1 81 ...

Страница 82: ...ser 2 security settings or scroll to configure an alternative User ENABLE user 2 security settings displays the PIN entry screen for User 2 To define a four digit User 2 PIN use the keys to select each digit from 0 9 Once you have the required digit press the NEXT DIGIT key After selecting the fourth digit press ENTER 82 m 730un en 08 1 ...

Страница 83: ...the functionality and press ENABLE User 2 PIN will allow access to only the enabled functionality to disable functionality highlight the enabled functionality and press DISABLE When all the required functionality has been enabled press FINISH m 730un en 08 1 83 ...

Страница 84: ...be displayed A PIN is now required to access all functionality The Master PIN accesses all pump functionality and the User 1 and User 2 PINs access only the defined functionality To enter the PIN use the keys to select each digit from 0 9 Once you have the required digit press the NEXT DIGIT key After selecting the fourth digit press ENTER 84 m 730un en 08 1 ...

Страница 85: ...played NOTE this screen will also display if the PIN entered does not allow access to that functionality If a PIN number is entered that is already in use the following screen will be displayed press CHANGE to input an alternative PIN or EXIT to abort m 730un en 08 1 85 ...

Страница 86: ...ot allow access to the functionality the following screen will be displayed Keypad beep From SECURITY settings scroll to Keypad beep using the keys and select ENABLE The pump will now beep at every key press 86 m 730un en 08 1 ...

Страница 87: ...f PIN code operation Anyone wishing to modify pump settings will still need to enter the PIN code 21 2 General settings To view the general settings menu select GENERAL SETTINGS from the main menu Auto restart This pump includes a feature called auto restart This setting only applies to pump operation in manual mode network mode and memodose mode If the pump is operating in any of these modes and ...

Страница 88: ...ed to network mode or analog mode it will respond to remote commands at any time including immediately after power on The Symbol is shown on the screen to warn users that the pump may operate without any manual intervention e g a remote setpoint could start the pump with no key press required The symbol is a warning that the pump could remotely activate at any time It will always be displayed when...

Страница 89: ...ELECT All flow rates displayed on screens will now be in the chosen units If a mass flow unit is selected the specific gravity of the fluid must be entered The following screen is displayed Use the keys to enter the value of the specific gravity and press SELECT m 730un en 08 1 89 ...

Страница 90: ...nu entry and press SELECT If a pump label has been previously defined this will be displayed on screen to allow editing otherwise it will display the default label WATSON MARLOW Use the keys to scroll through the available characters for each digit The available characters are 0 9 A Z and SPACE Press NEXT to move onto the next character or PREVIOUS to move back to the previous character 90 m 730un...

Страница 91: ...y and return to the general settings menu Pumphead type Select GENERAL SETTINGS from the main menu Use the keys to move the selection bar over Pumphead type and press SELECT The following screen will be displayed m 730un en 08 1 91 ...

Страница 92: ...Use the keys to move the selection bar over Pumphead and press SELECT Use the keys to move the selection bar over the required pumphead type and press SELECT 92 m 730un en 08 1 ...

Страница 93: ...rial Select Tube size from GENERAL SETTINGS then use the keys to move the selection bar over Bore size and press SELECT Use the keys to move the selection bar over the tube size to be used and press SELECT m 730un en 08 1 93 ...

Страница 94: ...yed as pressure and bore This screen also allows you to select the tube material used Use the keys to move the selection bar over Tube material and press SELECT Use the keys to move the selection bar over the tube material to be used and press SELECT 94 m 730un en 08 1 ...

Страница 95: ...git The available characters are 0 9 A Z and SPACE Press NEXT to move onto the next character or PREVIOUS to move back to the last character Press FINISH to save the entry and return to the general settings menu Restore defaults To restore the factory default settings select Restore defaults from the general settings menu There are two confirmation screens to ensure that this function is not carri...

Страница 96: ...age Select language from the general settings menu to choose an alternative display language for the pump The pump must be stopped before changing the language Use the keys to move the selection bar to your required language Press SELECT to confirm 96 m 730un en 08 1 ...

Страница 97: ...Please see Mode menu on page 1 for further details 21 3 Control settings Select CONTROL SETTINGS from the main menu to access the sub menu shown below Use the keys to move the selection bar Press SELECT to choose the required function Speed limit The maximum speed the pump is capable of running at is 360rpm Select Speed limit from the control settings menu to define a lower maximum speed limit for...

Страница 98: ...max_flow recalibrated Reset run hours Select Reset run hours from the control settings menu Select RESET to zero the run hours counter The run hours counter can be viewed by pressing INFO from your home screen The following screen will be displayed Press RESET to reset the run hours or CANCEL to return to the CONTROL SETTINGS menu 98 m 730un en 08 1 ...

Страница 99: ...CONTROL SETTINGS menu Outputs 1 to 4 Use the keys and press SELECT to choose which output to configure Use the keys and press SELECT to choose which pump status you require for the chosen output The tick symbol indicates the current setting m 730un en 08 1 99 ...

Страница 100: ...s and press SELECT to choose the logic state of the chosen output Press SELECT to program the output or BACK to cancel 4 20mA output Select 4 20mA to configure the pump s 4 20mA output response 100 m 730un en 08 1 ...

Страница 101: ...output will be scaled to the same range as the 4 20mA input i e if the 4 20mA input has been scaled to provide 4mA 0 rpm and 20mA 20 rpm then an input of 12mA will result in a set speed of 10 rpm and an output of 12mA 21 5 Configure inputs Select Configure inputs from the CONTROL SETTINGS menu Use the keys and press SELECT to choose which input to configure Use the keys and press SELECT to choose ...

Страница 102: ...his model Inputs 4 and 5 are configured for a pressure sensor Disable remote stop in manual mode Users can disable enable the remote stop input when the pump is in manual mode by using the following sequence to configure the start stop settings 102 m 730un en 08 1 ...

Страница 103: ...efault is û The start stop input is not disabled in manual mode Press SELECT to change the setting to ü Press HOME to return and store the setting The input is now disabled in manual mode m 730un en 08 1 103 ...

Страница 104: ...l mode The setting isü The start stop input is disabled Press SELECT to open the logic state menu Use the keys and press SELECT to choose the logic state of the chosen input for your connected control hardware 104 m 730un en 08 1 ...

Страница 105: ...Press HOME to return and store the setting The input is now enabled in manual mode 21 6 Help Help Select Help from the main menu to access the help screens m 730un en 08 1 105 ...

Страница 106: ...ut there is little or no flow make the following checks Check that fluid is supplied to the pump Check for any kinks or blockages in the lines Check that any valves in the line are open Check that the tube and rotor are in the pumphead Check that the tube is not split or burst Check that the correct wall thickness tube is being used Check the direction of rotation Check that the rotor is not slipp...

Страница 107: ...d Note Signal out of range over signal and leak detected error screens report the nature of an external condition They do not flash Error code Error condition Suggested action Er 0 FRAM write error Attempt to reset by switching power OFF ON Or seek support Er 1 FRAM corruption Attempt to reset by switching power OFF ON Or seek support Er 2 FLASH write error during drive update Attempt to reset by ...

Страница 108: ...Check supply Power OFF ON may reset Er20 Signal out of range Check analog control signal range Trim signal as required Or seek support Er21 Over signal Reduce the analog control signal Err50 Communication error internal pump communications error and not a network error Attempt to reset by switching power OFF ON Or seek support 22 3 Technical support Watson Marlow Fluid Technology Group Falmouth Co...

Страница 109: ...23 Drive maintenance There are no user serviceable parts inside the pump Please contact your local Watson Marlow representative to arrange repair m 730un en 08 1 109 ...

Страница 110: ... main fuse type T5A H 250V 20mm Pack of 5 MRA3083A Foot Pack of 5 MNA2101A Module Seal MN2516B Module switch cover MN2505M Gland Std GR0056 Glands EMC GR0075 Sealing washer for blanking plug or gland GR0058 Snap Fit vent MN2513B 110 m 730un en 08 1 ...

Страница 111: ...y on 730 series pumps is provided by the tool lockable pumphead track Secondary backup protection is provided in the form of an electrical guard switch which stops the pump if the pumphead track is opened The electrical guard switch on cased pumps should never be used as primary protection Always disconnect the mains power supply to the pump before opening the pumphead guard 720R and 720RE 1 2 3 4...

Страница 112: ...Refitting 1 2 3 112 m 730un en 08 1 ...

Страница 113: ...the pump from the mains power supply before opening any guard or track or performing any positioning removal or maintenance operation 26 1 Continuous tubing 720R 1 2 3 4 5 6 26 2 Tube elements 720RE 1 2 3 4 5 6 7 8 9 m 730un en 08 1 113 ...

Страница 114: ...sure to less than one minute risk of attack Halogenated chlorinated solvents Not recommended possible risk to polycarbonate tube clamp adjusters and polypropylene tube clamp locators Alcohols general No precaution necessary Glycols Minimize rotor cap and clutch boot exposure to less than one minute risk of attack Estersolvents Remove guard Minimize rotor cap and tube clamp location cap exposure to...

Страница 115: ...on N IP66 NEMA 4X S SCADA IP66 NEMA 4X F F IP66 NEMA 4X Plug options U UK mains plug E EU mains plug A American mains plug K Australia mains plug R Argentina mains plug C Swiss mains plug D India South Africa mains plug B Brazil mains plug Only available with American mains plug U and Du models only F module for KROHNE flow sensor m 730un en 08 1 115 ...

Страница 116: ...048 913 A127 048 15 9 5 8 189 902 0159 048 933 0159 048 913 A159 048 19 0 3 4 191 902 0190 048 933 0190 048 913 A190 048 25 4 1 92 902 0254 048 933 0254 048 913 A254 048 mm inch Neoprene STA PURE Series PCS 9 6 3 8 193 961 0096 048 12 7 1 2 88 920 0127 048 961 0127 048 15 9 5 8 189 920 0159 048 961 0159 048 19 0 3 4 191 920 0190 048 961 0190 048 25 4 1 92 920 0254 048 961 0254 048 116 m 730un en 0...

Страница 117: ... 3 4 191 961 0190 PFT 933 0190 PFT 913 A190 PFT 25 4 1 92 961 0254 PFT 933 0254 PFT 913 A254 PFT Industrial elements with PP Cam and Groove connectors mm inch Marprene TL Neoprene Pumpsil silicone 12 7 1 2 88 902 0127 PPC 920 0127 PPC 913 A127 PPC 15 9 5 8 189 902 0159 PPC 920 0159 PPC 913 A159 PPC 19 0 3 4 191 902 0190 PPC 920 0190 PPC 913 A190 PPC 25 4 1 92 902 0254 PPC 920 0254 PPC 913 A254 PPC...

Страница 118: ... 720R 1 MRA0036A Rotor assembly 720RX 2 MRA0104A Knob assembly 4 8mm wall tubing 3 CN0090 Coupling half 4 MR0880C Tube clamp 5 MRA3061A Foot assembly 6 CN0229 M12 blanking plug 7 CN0088 Coupling spider 8 MRA0027A Pivot pin assembly 8 MRA0034A Pivot pin assembly 720RX 9 FN0611 M8 x 16mm screw 118 m 730un en 08 1 ...

Страница 119: ...pare Description 10 MR0662T Stud Set to 61mm 11 MRA3063A Track assembly 12 CN0228 M25 blanking plug 13 MR0882M Eccentric bush 14 MR3041T M8 x 307mm bolt 720RX 14 MR3040T M8 x 157mm bolt 720R m 730un en 08 1 119 ...

Страница 120: ...036A Rotor assembly 720REX 2 MRA0319A Knob assembly 4 8mm wall tubing 3 CN0090 Coupling half 4 MR1118T Sliding clamp 5 MRA3061A Foot assembly 6 CN0229 M12 blanking plug 7 CN0088 Coupling spider 8 MRA0027A Pivot pin assembly 8 MRA0034A Pivot pin assembly 720REX 9 FN0611 M8 x 16mm screw 120 m 730un en 08 1 ...

Страница 121: ...are Description 10 MR0662T Stud Set to 61mm 11 MRA3064A Track assembly 12 CN0228 M25 blanking plug 13 MR0882M Eccentric bush 14 MR3041T M8 x 307mm bolt 720REX 14 MR3040T M8 x 157mm bolt 720RE m 730un en 08 1 121 ...

Страница 122: ... simplicity but are accurate to within 5 well within the normal tubing tolerance variation of flow rate They should therefore be taken as a guide Real flow rates in any application must be determined empirically 720R and 720RE flow rates 730 cased pumps performance limits Single pumphead 720R 720RE 0 25 bar 3 6psi 0 5 bar 8psi 1 bar 15psi 1 5 bar 22psi 2 bar 30psi Max speed rpm Max flow L hr USGPH...

Страница 123: ...e psi 0 2 4 6 8 pressure bar pressure psi 10 5 20 30 200 300 100 400 500 flow rate litres hour flow rate USGPH pressure mmhg bar pressure psi pressure psi Suction bar Pressure bar pressure bar 25 4mm 19 0mm 15 9mm 12 7mm 9 56mm 0 53 0 40 0 27 0 13 0 25 0 50 1 00 1 50 2 00 m 730un en 08 1 123 ...

Страница 124: ... 1100 291 200 870 230 175 760 261 15 9mm 0 6 300 1800 476 200 1200 317 175 1100 291 19 0mm 0 7 300 2500 660 200 1700 449 160 1390 366 25 4mm 1 0 300 3300 872 200 2200 581 The maximum speed is reduced at increased discharge pressures to ensure safe running of the pump pressure psi 0 2 4 6 8 0 500 1000 1500 2000 2500 3000 3500 pressure psi 10 5 20 30 200 400 600 800 400 300 200 100 0 flow rate litre...

Страница 125: ...e registered trademarks of Watson Marlow Limited Tri Clamp is a registered trademark of Alfa Laval Corporate AB STA PURE Series PCS and STA PURE Series PFL are trademarks of W L Gore and Associates EtherNet IP is a trademark of ODVA Inc Studio 5000 is a trademark of Rockwell Automation m 730un en 08 1 125 ...

Страница 126: ...rect but Watson Marlow Fluid Technology Group accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING This product is not designed for use in and should not be used for patient connected applications 126 m 730un en 08 1 ...

Страница 127: ...lication history All versions updated combined to single source and unified to Issue 4 09 18 m 730un gb 01 730 UN pump First published 01 17 m 730en 01 530 EN pump First published 04 2020 m 730un en 08 1 127 ...