Full scale 0 to 125 rpm
— The 4-20 mA output will be based on the full speed range of the pump. At 0
rpm the pump will output 4 mA, at 125 rpm the pump will output 20 mA.
Match input scale
— The 4-20 mA output will be scaled to the same range as the 4-20 mA input. i.e. if
the 4-20 mA input has been scaled to provide 4 mA=0 rpm and 20 mA=20 rpm, then an input of 12 mA
will result in a set speed of 10 rpm and an output of 12 mA.
22.5
Configure inputs
Select
Configure inputs
from the CONTROL SETTINGS menu.
Use the
∧
/
∨
keys and press
SELECT
to choose which input to configure.
Use the
∧
/
∨
keys and press
SELECT
to choose the logic state of the chosen input.