16 MemoDose
The pump can dispense a set quantity or dose of fluid each time the key is pressed.
This is the MemoDose facility.
Set the pump
speed and direc-
tion. Place a suit-
able measuring
container at the
outlet and
START
the pump.
When the required vol-
ume of fluid has been
dispensed, press the
STOP
key twice within
half a second. This
starts the MemoDose
feature.
The pump has made a record of the fluid it has just dispensed.
You may now repeat this dose or adjust the quantity as required.
The display will show “
dos
“ for 3 seconds. Then the display will
change to show 100%.
S, U, Du
Measure the quantity of fluid which has been dispensed. If the quantity is
correct press
START
to repeat the dose.
If the initial dose is larger than required use
the
DOWN
key to reduce the volume %
showing on the display. This will reduce the
next dose to be dispensed by the pump.
If the initial dose was smaller than
required use the
UP
key to increase
the next dose to be dispensed by
the pump.
Press
START
. The pump will dispense the new dose
and the display will count down as this dose proceeds.
The pump will stop when the new dose is complete.
Measure the new dose. If it is correct you may now
repeat this dose as often as required. The keypad
lock can be used to prevent further changes.
Use the
UP
and
DOWN
keys to further adjust the
dose until the correct quantity is obtained. You may
adjust the dose size down to 1% or up to 999%
Press the
STOP
key twice within half a second to exit MemoDose
and return to manual operation.