7
Pump specifications
Table 1 - Specification ratings
Operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Storage temperature
730: -25 °C to 65 °C (-13 °F to 149 °F)
Humidity (non-condensing)
80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104
°F)
Maximum altitude
2000 m (6560 ft)
Power Rating
730: 350 VA
Supply voltage
100-120 V/200-240 V 50/60 Hz 1 pH (Subject to regional cord sets
and supply)
Maximum voltage fluctuation
+/-10 % of nominal voltage. A well regulated electrical mains
supply is required along with cable connections conforming to
the best practice of noise immunity.
Full load current
730: <1.5 A @ 230 V; <3.0 A @ 115 V
Fuse rating
T2.5AH250V (5x20 mm)
Installation category
(overvoltage category)
II
Pollution degree
2
IP
730: IP66 to BS EN 60529. Meets the requirements of NEMA 4X to
NEMA 250 *(indoor use - protect from prolonged UV exposure)
dB rating
730: < 85 dB (A) @ 1 m
Control ratio
730: 0.1-360 rpm (3600:1)
Maximum speed
730: 360 rpm
12