8
Pump specifications
8.1
Specification ratings
Operating temperature
5 °C to 40 °C (41 °F to 104 °F)
Storage temperature
730: -25 °C to 65 °C (-13 °F to 149 °F)
Humidity (non-condensing)
80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F)
Maximum altitude
2000 m (6560 ft)
Power Rating
730: 350 VA
Supply voltage
100-120 V/200-240 V 50/60 Hz 1 pH (Subject to regional cord sets
and supply)
Maximum voltage fluctuation
+/-10 % of nominal voltage. A well regulated electrical mains supply
is required along with cable connections conforming to the best
practice of noise immunity.
Full load current
730: <1.5 A @ 230 V; <3.0 A @ 115 V
Fuse rating
T2.5AH250V (5x20 mm)
Installation category
(overvoltage category)
II
Pollution degree
2
IP
730: IP66 to BS EN 60529. Equivalent to NEMA 4X to NEMA 250 *
(indoor use - protect from prolonged UV exposure)
dB rating
730: < 85 dB (A) @ 1 m
Control ratio
730: 0.1-360 rpm (3600:1)
Maximum speed
730: 360 rpm
8.2
Weights
730
Drive only
+ 720R, 720RE
+ 720RX, 720REX
kg
lb oz
kg
lb oz
kg
lb oz
kg
lb oz
IP66 (NEMA 4X)
18.5
40 13
25
55 2
31.5
69 7
m-730en-en-08.1
13