Error code
Error condition
Suggested action
Er 3
FLASH corruption
Attempt to reset by switching power OFF/ON. Or seek
support.
Er 4
FRAM shadow error
Attempt to reset by switching power OFF/ON. Or seek
support.
Er 9
Motor stalled
Stop pump immediately. Check pumphead and tube.
Power OFF/ON may reset. Or seek support.
Er10
Tacho fault
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er14
Speed error
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er15
Over current
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er16
Over voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er17
Under voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er20
Signal out of range
Check analog control signal range. Trim signal
as required. Or seek support.
Er21
Over signal
Reduce the analog control signal.
Err50
Communication error (internal
pump communications error and
not a network error)
Attempt to reset by switching power OFF/ON.
Or seek support.
23.2
Technical support
Watson-Marlow Fluid Technology Group
Falmouth, Cornwall
TR11 4RU
UK
Contact your local Watson-Marlow representative for support.
www.wmftg.com/contact
106
m-530en-en-01
Содержание 530 Series
Страница 35: ...13 7 Network topology Star network Ring network m 530en en 01 35...
Страница 83: ...20 5 Flow Sensor Reading The flow sensor value can be read via the Flow sensor reading screen m 530en en 01 83...
Страница 104: ...22 Help 22 1 Help Select Help from the main menu to access the help screens 104 m 530en en 01...