Table 14 - Errors and warnings
ADI
Name
Access
Type
Description
102
Error bit field
Read
Uint32
Bit 0
Lead detected, Leak detect signal
high requires clearing and
acknowledging before pump can
resume.
Bit 1
Motor Stall error active If Set the
pump has a Motor Stall Error.
Please follow onscreen instructions
Bit 2
Motor Speed error, If set pump has
a speed error. Please follow
onscreen instructions
Bit 3
Over Current error active, If set the
pump has an over current error.
Please follow onscreen instructions
Bit 4
Over voltage error active, If set the
set the pump has an over voltage
error. Please follow onscreen
instructions
Bit 5
Guard open, If set then the guard
has been opened. Please follow
onscreen instructions to clear.
Bit 6
Flow sensor error active, if set flow
sensor error is active
Bit 7
Pressure sensor error active, if set
flow sensor error is active
m-530pn-en-09 02-02-22
89