Routine Maintenance
30
Plockmatic PowerSquare™ 224 - Service Training Workbook
9.
Routine Maintenance
9.1
Operator Maintenance
Operator maintenance is documented in Chapter 6 of the user manual and in
Section 6.17 of the PSQ Service Manual.
Operator Maintenance Plan
Perform these tasks:
Lubricate the stitch head (operator lubrication).
Clean the former roller.
Clean the trimmings-removal fingers.
Clean excess grease from the stitch head.
9.2
Technical Maintenance
Technical Maintenance is documented in the Service Manual (see 1.5 “Routine
Maintenance”).
The recommended service interval is every 6 months.
In addition, after 1 million stitches or 3 spools of stitch-wire the stitch head must
be disassembled and inspected for wear. There is a kit of replacement parts for
this procedure:
• G8 Stitch Head Maintenance Kit, Part No. 914-880
9.3
Care Pack
The PowerSquare is shipped with a care pack of essential spare parts.
If spare parts are used, the care pack must be replenished. Order forms are
included in the care pack.
Interval
Task
• Every week
Clean the machine.
• Every month
or
• When a new stitch-wire is installed
if this interval is shorter
or
• When the message
OPERATOR
MAINTENANCE
is displayed on the
screen.
Lubricate the stitch head.
Clean the former roller.
Clean the polyurethane strips in the form
clamp.
Clean the trimmings-removal fingers.
Clean excess grease from the stitch head