Safety Information

SAFETY INFORMATION

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

AVOIDING THE RISK TO CHILDREN
DANGER:

RISK OF CHILD DROWNING.

Extreme caution must be exercised to prevent unauthorized access by children.  To avoid accidents,

ensure that children cannot use a spa unless they are supervised at all times.

WARNING:

• To reduce the risk of injury, do not permit children to use this spa unless they are closely supervised at all times.
• To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.

DO:

• Make sure you always lock the child resistant locks after using the spa for your children’s safety. Every Hot Spring

®

spa is equipped with a

locking cover that meets the ASTM F1346-91 Standard for Safety Covers.

• Test the water temperature with your hand before allowing children to enter the spa to be sure that it’s comfortable. Children are

especially sensitive to hot water.

• Remind children that wet surfaces can be very slippery. Make sure that children are careful when entering, or exiting the spa.

DON’T:

• Allow children to climb onto the spa cover.
• Allow children to have unsupervised access to the spa.

AVOIDING THE RISK OF ELECTROCUTION

Risk of electrocution

• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death, or serious personal injury due to electrocution if direct burial-type

cable is not used, or if improper digging occurs.

• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 10 AWG

(6 mm

2

) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical

equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.

WARNING:

• To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious personal injury

due to electrocution.

• Your spa is provided with a Ground Fault Circuit Interrupter for user and equipment protection.  To ensure proper operation of this

important safety device, test according to the following instructions per electrical configuration.

Cord-Connected 115 volt, 20 amp models:

The GFCI is located at the end of the power cord. Before each use, with the unit operating,

push the TEST button. The unit should stop operating and the GFCI power indicator will go out. Wait 30 seconds and then reset the GFCI
by pushing the RESET button. The GFCI power indicator will turn on, restoring power to the spa. If the interrupter does not perform in this
manner, there may be an electrical malfunction and with it, the possibility of an electric shock. Disconnect the power until the problem has
been corrected.

230 volt, permanently installed or converted models:

• A ground terminal is provided on the terminal block (TB-1, system ground terminal) located inside the control box. To reduce the risk of

electric shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated
copper wire. The wire must be equivalent in size to the circuit conductors supplying the equipment. In addition, a bonding terminal
(pressure wire connector) is provided on the outside of the control box for bonding to local ground points. To reduce the risk of electric
shock, this connector should be bonded with a No. 10 AWG (6 mm

2

) solid copper wire to any metal ladders, water pipes, or other metal

within 5 feet (1.5 m) of the spa to comply with local requirements. The means of disconnection must be readily accessible, but must be
installed at least 5 feet (1.5 m) from the spa.

• Your spa is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.

Содержание Landmark

Страница 1: ...Owner s Manual Owner s Manual...

Страница 2: ...__ TELEPHONE ________________________________________________________________________________________________________________ SPA MODEL SERIAL NUMBER __________________________________________________...

Страница 3: ...el J 33 CONTROL PANEL OPERATIONS Main Control Panels 34 Control Panels 34 Indicator Lights 34 Locking Features 34 Main Control Panel Buttons and Display 35 Water Care 36 Auxiliary Control Panel 36 115...

Страница 4: ...the unit as needed to comply with local requirements WARNING To reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result in death or serious personal injury d...

Страница 5: ...extension cord may cause a voltage drop which will cause overheating of the jet pump motor and motor damage Attempt to open the electrical control box There are no user serviceable parts inside RISKS...

Страница 6: ...est the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN Each Hot Spring spa is shipped with a SAFETY SIGN in the owner s package The sign which is required as a co...

Страница 7: ...s 620 lbs 281 kg 4 556 lbs 2 067 kg 105 lbs per square foot 115 volt 20 amp Dedicated GFCI protected circuit or 230 volt 50 amp Single phase GFCI protected circuit Prodigy Model H 33 84 m 90 square fe...

Страница 8: ...A O A B E D M F F F G G OVERHEAD VIEW A SmartJet system lever B Moto Massage jet Comfort Control system lever C JetStream jet Comfort Control system lever D Precision jets Comfort Control system leve...

Страница 9: ...oothing Seven jets K JetStream jet L Heater return and spa drain M Light lens N Filter compartment O Main control panel P Auxiliary control panel Grandee Model G 1 Wavemaster jet pump 2 No Fault 6000...

Страница 10: ...artJet system lever B Moto Massage jet Comfort Control system lever C Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet with rotary noz...

Страница 11: ...HEAD VIEW A SmartJet system lever B Moto Massage jet Comfort Control system lever C Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage jet w...

Страница 12: ...T OVERHEAD VIEW A SmartJet system lever B Moto Massage jet Comfort Control system lever C Precision jets Comfort Control system lever D Pillow E Hydromassage jet with directional nozzle F Hydromassage...

Страница 13: ...MENT COMPARTMENT OVERHEAD VIEW A SmartJet system lever B JetStream jet Comfort Control system lever C Precision jets Comfort Control system lever D Hydromassage jet with directional nozzle E Hydromass...

Страница 14: ...VIEW A SmartJet system lever B JetStream jet Comfort Control system lever C Moto Massage jet Comfort Control system lever D Precision jets Comfort Control system lever E Pillow F Hydromassage jet wit...

Страница 15: ...ntact your local electrical code compliance inspector for more information inspection for proper grounding may be required before pouring concrete to form the slab If you place the spa on the ground e...

Страница 16: ...set it aside Carefully remove the shims and keep them together remembering the corner from which each set of shims came 5 With more than one person lifting lift the lowest side of the spa the one wit...

Страница 17: ...E All dimensions are approximate measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from edge then center middle shims U P S I D E D O W N...

Страница 18: ...ctions Sovereign Model I ILE Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions 15 leveling points place shims approx 18 in from ed...

Страница 19: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions Spa Leveling Instructions 10 leveling points place shims approx 15 in from edge...

Страница 20: ...Leveling Points NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions Spa Leveling Instructions 10 leveling points place shims approx 15 in from edge...

Страница 21: ...the IQ 2020 spa control box Loosen the screws on the front of the control box Remove the screws and the control box cover 3 Route the electrical service from the subpanel into the spa equipment compar...

Страница 22: ...t is essential that you understand and apply these installation requirements Your Hot Spring spa has been carefully engineered to provide maximum safety against electric shock Remember connecting the...

Страница 23: ...iers to place the program jumpers as shown in Figure 2 use Watkins P N 36021 NOTE The program jumpers JP 1 JP 2 and JP 3 must be set correctly for the spa to operate Figure 2 illustrates the correct j...

Страница 24: ...e TEST button on each GFCI breaker and observe it click off 2 Wait 30 seconds then push the breaker switch to the OFF down position to ensure that it has completely disengaged then push the breaker sw...

Страница 25: ...d the National Electric Code When the spa is installed the power cord will come out of the bottom of the equipment compartment door For your safety when the electrician is installing the 20 amp single...

Страница 26: ...jet pump and offer two jet menus The Landmark Grandee Vanguard and Sovereign Limited Edition are equipped with a No Fault 6000 stainless steel high watt density heater The heating system consists of...

Страница 27: ...e that the SmartJet lever is pointing to the 3 o clock position see illustration in SmartJet system section 4 Adjust Total Alkalinity TA to 125 ppm Calcium Hardness CH to 150 ppm then spa water pH to...

Страница 28: ...adjusting the mixture of air and water Jets with an adjustable faceplate are controlled by turning the faceplate clockwise for a stronger flow counterclockwise for a softer flow Jets without an adjust...

Страница 29: ...the JetStream jets can be altered except the ones found in the FootWell system using only the Comfort Control lever with the steel blue or dark grey lever JetStream jets located in the FootWell are n...

Страница 30: ...2 Soothing Seven jets 1 directional hydromassage 1 JetStream jet on right wall 1 DreamJet massage pillow on right front Right Jet Pump Jet System 1 Right SmartJet lever in the 3 o clock position 3 Jet...

Страница 31: ...ll System 2 Precision jets on left seat calf area Right Jet Pump Jet System 2 Right SmartJet lever in the 9 o clock position 1 Moto Massage jet on right rear 4 Precision jets above right Moto Massage...

Страница 32: ...Cluster system on right wall 2 dual port rotary 1 directional hydromassage 2 Soothing Seven jets on left wall 2 Precision jets on left rear seat calf area 2 Precision jets on right rear seat calf are...

Страница 33: ...o Massage jet 2 JetStream jets in FootWell System 1 directional hydromassage jets on left wall 3 Jet Cluster system on left wall 2 dual port rotary 1 directional hydromassage Jet System 1 SmartJet lev...

Страница 34: ...ecision jets above Moto Massage jet 10 Precision jets on right rear 2 dual port rotary jets on right front 1 JetStream jet in FootWell System Jet System 2 SmartJet lever in the 6 o clock position 1 Mo...

Страница 35: ...assage jet on left wall 2 Soothing Seven jets on front left Jet System 2 SmartJet lever in the 9 o clock position 1 JetStream jet on rear wall 3 Jet Cluster system on left rear 2 dual port rotary 1 di...

Страница 36: ...t System 2 SmartJet lever in the 9 o clock position 1 Moto Massage jet on left rear 4 Precision jets above Moto Massage jet 2 Stacked hydromassage jets on back wall 1 directional hydromassage 1 dual p...

Страница 37: ...increase or decrease the temperature setting of the spa the ready indicator will turn off until the spa temperature reaches the acceptable range for the new set temperature Additionally a blinking RE...

Страница 38: ...he spa press the TEMP plus button The set temperature will be displayed unless the spa is locked in which case the word SPA is displayed with the lock symbol The set temperature display will automatic...

Страница 39: ...timer is on When activated the symbol will be visible even in bright light when the main display backlight is off In low light conditions the Summer Mode symbol will only be visible when the display i...

Страница 40: ...ion pump which can add heat to the water through normal operation heater and ozone if installed will immediately shut down for the next eight hours Additionally the summer mode display on the main con...

Страница 41: ...gallon from the bleedline system 6 When empty inspect the spa shell and clean as required Follow the Care of the Exterior Finish instructions 7 Close the drain valve and reinstall the drain cap 8 Rei...

Страница 42: ...ng period of time that is during a vacation or if the spa is winterized or when the spa water is being super chlorinated the spa pillows should be removed until the next spa use To remove and replace...

Страница 43: ...move tree sap use cigarette lighter fluid not charcoal lighter fluid Use sparingly and rinse with a saddle soap solution immediately afterwards then wipe dry Important reminders DO remove snow buildup...

Страница 44: ...andles DO NOT use any chemicals or cleaners except those recommended by Watkins Manufacturing Corporation or its Authorized Sales and Service Dealer DO NOT use hard sharp or metal objects such as a ca...

Страница 45: ...y gravitational flow 5 Remove the threaded cap from the secondary drain The remaining water about 1 gallon will drain from the bleedline system 6 Remove the filter cartridges then clean and store the...

Страница 46: ...ON THE THREE FUNDAMENTAL AREAS OF WATER MAINTENANCE Water Filtration Chemical Balance pH Control Water Sanitation Water sanitation is the responsibility of the spa owner achieved through the regular a...

Страница 47: ...apped oxidizer gas which may exist as a result of the shock treatment not daily sanitation may eventually cause discoloration or vinyl degradation to the bottom of the cover This type of damage is con...

Страница 48: ...below 7 are acidic Maintaining the proper pH level is extremely important for Optimizing the effectiveness of the sanitizer Maintaining water that is comfortable for the user Preventing equipment dete...

Страница 49: ...dirt detergents algae and chemicals Sodium Dichlor chlorine is the only recommended sanitizer that will work in conjunction with all of the other products in this system FreshWater III high output oz...

Страница 50: ...1 1 4 tablespoons Jetsetter Model J 1 tablespoon Add one half 1 2 teaspoon of chlorine per 250 gallons Landmark Model S 1 teaspoon Grandee Model G 1 teaspoon Vanguard Model V 3 4 teaspoon Sovereign Mo...

Страница 51: ...circulation pump filter standpipe it is subjected to the continuous flow of water created by the pump s 24 hour circulation The flowing water through a chemical erosion process carries with it the sil...

Страница 52: ...cover at least half way to allow the chlorine gas to vent off The high concentration of chlorine gas which may exist as a result of super chlorination not daily sanitation may eventually cause discol...

Страница 53: ...eatly enhances the quality of the spa water when used to supplement the spa owner s regular water maintenance program Contrary to some information circulated throughout the pool and spa industry regar...

Страница 54: ...STRY QUESTIONS Question Why can t I use a floater to sanitize my spa water Answer Watkins Manufacturing Corporation does not recommend the use of a floater for three reasons 1 The floater is unable to...

Страница 55: ...Generally corrosion is caused by low pH or by water with levels of TA CH pH or sanitizer which are outside the recommended ranges DPD The preferred reagent used in test kits to measure the Free Availa...

Страница 56: ...CUT OFF The Hot Spring spa No Fault 6000 heater is called the No Fault heater because it comes with an unconditional warranty This means that any failure during the stated warranty period that require...

Страница 57: ...ive of Watkins Manufacturing Corporation Alteration shall include any component or plumbing change electrical conversion or the addition of any non approved sanitation or water purification device or...

Страница 58: ...ets and light operate Ready indicator is dark Jets weak or surging Light inoperative Power failure GFCI tripped Heater high limit thermostat tripped Spa lock activated Heater thermal cut off tripped C...

Страница 59: ...i d g e S o a k F i l t e r C a r t r i d g e S o a k F i l t e r C a r t r i d g e R e s t a i n E v e r w o o d R e s t a i n E v e r w o o d S p a C a b i n e t S p a C a b i n e t C l e a n a n d...

Страница 60: ...EL JC 4 02 2002 Watkins Manufacturing Corporation Hot Spring Built for a lifetime of relaxation Endurol Moto Massage Landmark Grandee Vanguard Sovereign Prodigy Jetsetter Jet Cluster SmartJet Comfort...